background image

7

600

510

Gas Connection

Electrical Supply

Cord

107

ACS6SG1

 

 

 

NG 

 

Universal LPG

2 Semi-rapid burner  

6. MJ/h   

6.0 MJ/h

 Auxiliary burner   

.6 MJ/h   

.6 MJ/h

4 Triple ring burner   

1.0 MJ/h  

1.0 MJ/h

8 Control knob for burner

TECHNICAL CHARACTERISTIC TABLES

BURNERS

GAS

NORMAL 

PRESSURE

INJECTOR 

DIAMETER

TAPE BY 

PASS 

DIAMETER

NOMINAL 

HEAT INPUT

(MJ/h)

N° DESCRIPTION

KPa

1/100 mm

1/100 mm

Max.

Min.

2

SEMI-RAPID

Universal LPG

2.75

65

1

6.0

1.2

Natural

1.00

110

Adjust.

6.

1.5

AUXILIARY

Universal LPG

2.75

52

27

.6

0.9

Natural

1.00

80

Adjust.

.6

0.9

4

TRIPLE 

CROWN

Universal LPG

2.75

95

60

1.0

4.5

Natural

1.00

160

Adjust.

1.0

.4

The  manufacturing  firm  refuses  all  responsibility  for  any  possible  imprecision  in  this  booklet,  due  to 

misprints or clerical errors. It reserves the right to make all the changes that it will consider necessary in 

its own products, without effecting the essential characteristics of functionality and safety.

Содержание ACS6SG1

Страница 1: ...COD 208257 REV1 26 10 2007 600mm Gas Built in Hob MODEL ACS6SG1 INSTALLATION AND OPERATION MANUAL ...

Страница 2: ...ipment cut power supply off and make it cool down Make sure that air circulates around the gas equipment Insufficient ventilation produces a lack of oxygen In case of an intense or prolonged use of the equipment it may be necessary to improve aeration for example by opening a window or increasing the mechanical suction power if it exists The products of combustion must be discharged outside throug...

Страница 3: ...s in the vicinity of this appliance Do not place unstable or deformed pots on the burner so as to prevent them from overturning or overflowing Make sure that pot handles are placed properly When the burner is started up check that the flame is regular and before taking pots away always lower the flame or put it out ABNORMAL OPERATION Any of the following are considered to be abnormal operation and...

Страница 4: ...nstalled to guarantee an adequate ventilation with the lower air entering with a cross section of at least 200cm2 and the higher air exiting with a cross section of at least 60 cm2 Fastening the top Every cook top is equipped with a special washer A set of clips are also supplied for mounting the cook top For the installation proceed as follows Remove the trivets and burners from the top Turn the ...

Страница 5: ...at the available gas supply matches the Data Label When converting from Natural Gas to Universal LPG ensure that the NG regulator is removed and replaced with the Test Point Assembly An AGA Ap proved gas regulator suitable for a supply pressure of 2 75kPa should be part of the gas tank supply and the test point pressure should be adjusted to 2 75kPa Replacing the nozzles If the equipment is adjust...

Страница 6: ... 1 2 3 4 5 6 8 7 9 V ...

Страница 7: ...100 mm 1 100 mm Max Min 2 SEMI RAPID Universal LPG 2 75 65 31 6 0 1 2 Natural 1 00 110 Adjust 6 3 1 5 3 AUXILIARY Universal LPG 2 75 52 27 3 6 0 9 Natural 1 00 80 Adjust 3 6 0 9 4 TRIPLE CROWN Universal LPG 2 75 95 60 13 0 4 5 Natural 1 00 160 Adjust 13 0 3 4 The manufacturing firm refuses all responsibility for any possible imprecision in this booklet due to misprints or clerical errors It reserv...

Страница 8: ...1800 805 300 PRODUCT SERVICE PHONE NUMBER ...

Отзывы: