Revision Date
– 22/12/2014
page 72
Fit the supplied 2-way connector to terminal
“-” on
the compressor control unit.
Connect the black wire and connector removed in
the previous step to the 2-way connector.
Connect the blade terminal on the braided wire to
the second terminal on the 2-way connector.
Route the braided wire along the main wiring
loom as shown.
Fix the ring terminal on the braded wire to the
steel frame of the fridge cabinet using the
supplied self drilling screw as shown.
NOTE: If the fridge already has an earth
strap attached to this frame, the
existing bolt can also be used to
fasten the new braided wire.
Secure the braided wiring to the existing wiring
loom using the supplied cable ties.
CAUTION: Ensure that all cables are securely
fastened away from sharp, moving
or hot surfaces.
Existing black
wire
New braided
wire
Self drilling
screw
Existing earth strap with
optional mounting bolt
Braided
wire
route
Cable tie to
existing loom