Page 43
3.6.4.2
Ethernet menu
Ethernet
connection is preferred for Aranet PRO/PRO+, as it is generally more reliable. In the
Ethernet
menu there are two options - either to have it work in
DHCP
client mode or have a
Static
IP.
Factory settings
of Aranet PRO/PRO+ Ethernet interface are:
•
DHCP client – On;
•
Static IP fallback – On;
•
IP address – 192.168.205.100;
•
Subnet Mask – 255.255.255.0.
Static IP fallback
switch is visible when DHCP client mode is selected. When switched
ON
, and Aranet
PRO/PRO+
did not receive IP address
from DHCP server, last settings entered in
IP address
,
Subnet
mask
,
Default gateway
and
DNS server
fields are applied. If no settings were entered before, default
Factory settings are in force. The same settings are in force after
NETWORK RESET
.
If
Static IP fallback
is switched
OFF,
no valid IP address is assigned to Aranet PRO/PRO+ Ethernet
interface when it
did not receive IP
address from DHCP server.
!NOTE!
Most routers have DHCP enabled by default, we recommend keeping this setting
for ease of set up. For more advanced users, however, static IP address set up is possible.
Globe
symbol with no crossover
indicates successful connectivity to network.