22
IMPLEMENT SETTINGS
11.3
Pressure sensor
1
Set the installed pressure sensor by selecting it from list in
(use keys
2
to scroll items, and key
3
to confirm).
The relevant configuration data will be automatically loaded (
4
Activate pressure sensor.
The item
Maximum pressure
can be modified only when the option
Other
is enabled.
1
4
Fig. 41
2
3
2
Fig. 42
Depending on the basic settings (
Flowrate reference sensor
,
chap
), the pressure sensor, once properly set up, can perform different functions:
• Pressure sensor: the pressure measured by the sensor is used to calculate the spray rate.
• Flowmeter: the pressure sensor displays ONLY the job pressure.
• Both: the pressure sensor displays the job pressure when the machine works within the flowmeter limits.
When the flowmeter operates outside the limits the pressure measured by the sensor is used to calculate the spray rate.
The table below indicates the values that are automatically set selecting the sensor code.
If the installed sensor is not displayed, select
Other
and enter the relevant values.
ARAG PRESSURE SENSOR
Type
Maximum pressure
bar
PSI
466113.200
20.0
290
466113.500
50.0
725
Other
50.0
725
Quits without confirming the
changes
Saves the changes
Delete
Quit
Confirm
Goes back to previous menu,
or scrolls the pages of a menu
(previous page)
Scrolls the pages of a menu
(next page)
Goes back to Main screen
Saves the changes to current
page