9
5.2
Power connection
CAUTION:
To avoid short circuits, do not connect the power cable connector before the installation
is completed.
Before powering up the monitor and control unit, make sure the battery voltage is as
specified (12 Vdc).
Bravo 14x is directly powered by the tractor battery (12 Vdc): ALWAYS switch on the monitor first; then
remember to manually switch off the monitor by means of the suitable button onto the control panel.
The tractor battery could get flat if Bravo 14x stays on for a long time if the engine is not
running: ensure monitor is off in case of long machine stops with engine stopped.
Power supply must be connected as shown in Fig. 3.
FUSE
12V
10 A
Red
Black
Use a power cord (code 466001) for an
easier device removal when not in use.
CAUTION:
• The power circuit must ALWAYS be fitted with a 10 Amp automotive fuse.
• All battery connections must be made with cables with a minimum cross section of
2,5 mm
2
.
• To avoid short circuits, do not connect the power cable connector before the installation
is completed.
• Use cables with suitable terminals to ensure correct connection of each individual wire.
Fig. 3