5.2 

Calibrating the metered by-passes

These cocks safeguard the constant distribution of liquid even in case of operation with one or two 
section valves closed.

Calibration must be carried out EACH TIME the type of nozzle is changed.

The metered by-pass calibration knobs are equipped with a graduated scale. Once each metered 
by-pass has been calibrated, enter the value of the graduated scale for the type of nozzle in use in 
the tables on page 17.  This means that it will not be necessary to recalibrate a given metered by-
pass the next time the same nozzles are used, but simply set it to its value in the tables.

1

Close one section valve by setting its corresponding switch on the 
control device to "OFF".

2

Adjust the corresponding compensation cock by turning the 
knob until the pressure level is restored on the pressure gauge 
that was previously set with all the section valves open.

3

Open and close the section valve (operate its switch on control 
device as needed) and make sure that pressure value remains 
steady.

If pressure fluctuates, repeat the operations described at step 

2

 

until no more fluctuation occurs.

CONTINUES

Содержание 463 Series

Страница 1: ...SERIE 463 465 PROPORTIONAL CONTROL UNIT FOR ORCHARD SPRAYER APPLICATIONS INSTALLATION USE AND MAINTENANCE 02...

Страница 2: ...and must accompany the equipment in case of sale or change of ownership Keep it for future reference ARAG reserves the right to modify the specifications and instructions regarding the product at any...

Страница 3: ...adjustments before operation 11 4 2 Adjustment of maximum operating pressure 13 5 Use 14 5 1 Calibration of operating pressure 14 5 2 Calibrating the metered by passes 15 5 2 1 Metered by pass calibra...

Страница 4: ...and not of the unit in general ARAG is not liable for direct or indirect damage due to the type of product used for treatment with its control units The operator has full liability for the use of the...

Страница 5: ...e 2b Proportional valve 3 Discharge valve 4 Filter 5 Boom section electric valves 6 Metered by passes 7 Pressure gauge adapter or pressure transducer connection IN Intake of liquid for spraying OUT A...

Страница 6: ...omputer Discharge valve open liquid sent to the tank the suction system if present starts functioning Discharge valve closed liquid sent directly to the circuit for application 4 Filter Protects nozzl...

Страница 7: ...he diameters of the chosen hose tails Use systems to secure the hoses that are suitable for the hoses in question It is recommended to install a pressure relief device Series 459 on general ARAG catal...

Страница 8: ...8 Observe unit mounting positions shown in Fig 3 Fig 3 STANDARD MOUNTING POSITION...

Страница 9: ...elow Take care Not to connect backflow hoses in the lower part of the tank with the intention of using them as hydraulic stirrers only place them in the upper part so the liquid drops down by gravity...

Страница 10: ...ed for ease of identification please see Fig 5 for a description of cable marks and their meanings Fig 5 Use only the cables supplied with ARAG computers or control boxes Do not pull on the cables Be...

Страница 11: ...they automatically turn off in case of over voltage to reset the valves remove power supply to the unit for about 20 secon ds Pressure readings are indicated by the pressure gauge or displayed at the...

Страница 12: ...onal valve turn the valve s knob anticlockwise proportional electric valve push the respective switch on the control unit down 5 Set the relevant switches on the control device to OFF to close all sec...

Страница 13: ...h the switch on the control unit set to OFF this delivers product to the unit 3 Gradually increase the number of revs of the pump until the maximum operating level is reached 4 Fully close the proport...

Страница 14: ...t 4 Set the relevant switches on the control device to ON to open all section valves 5 Now set the unit s pressure to the spraying value The operating pressure is set with the proportional valve proce...

Страница 15: ...at it will not be necessary to recalibrate a given metered by pass the next time the same nozzles are used but simply set it to its value in the tables 1 Close one section valve by setting its corresp...

Страница 16: ...ch section valve must be calibrated independently MIRRORED section valves Fig 6 you need calibrate only one part of the control unit right or left boom valves A and B calibrate the other part of the b...

Страница 17: ...ass calibration tables NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF N...

Страница 18: ...Follow the indications in the table below for the frequency of cleaning MANUAL CLEANING FREQUENCY Clean with clean water After each use Clean filter After each use Cleaning the filter recirculating t...

Страница 19: ...he system 4 Unscrew cover A anticlockwise and remove the cover and cartridge B 5 Wash the cartridge B and the lid A under running water 6 Remove any trapped items under running water Do not use compre...

Страница 20: ...t and the filter outlet itself This check is carried out as follows 1 Protective gloves goggles and clothing must be worn 2 Completely open the filter outlet by turning the tap anticlockwise 3 Follow...

Страница 21: ...any time it is deemed necessary 1 Protective gloves goggles and clothing must be worn 2 Start the pump and take it to its operating level 3 Set the relevant switches on the control device to OFF to c...

Страница 22: ...tem to operate for at least 2 minutes 7 Open the discharge valve with the switch on the control unit set to ON 8 Completely close the filter outlet by turning the tap clockwise End of par 6 2 2 Contin...

Страница 23: ...e Proportional valve drain passage clogged Clean drain passage A hydraulic agitator is connected to drain passage of proportional valve Remove hydraulic agitator and leave hole open Drain tube of prop...

Страница 24: ...eck electric connection Have gearmotor inspected at the nearest Service Centre Section valve plug gasket worn out Change worn gaskets Chemical residue on gasket and seat of section valve hose tail Cle...

Страница 25: ...Notes 25...

Страница 26: ...tallation and regulation damage or malfunction caused by the lack of ordinary maintenance such as cleaning of filters nozzles etc anything that can be considered to be normal wear and tear 3 Repairing...

Страница 27: ...10 CONFORMITY DECLARATION The declaration of conformity is available at www aragnet com in the relevant section...

Страница 28: ...are parts to make sure manufacturer guaranteed safety conditions are maintained in time Always refer to the internet address www aragnet com 42048 RUBIERA Reggio Emilia ITALY Via Palladio 5 A Tel 0522...

Отзывы: