Information on the integrated liquid cooler
This contains the pressure decrease, including the connection elements,
here in the example with the plug-in connections. It does not include ex-
ternally attached feed lines.
A water cooling system is integrated in the device, in the aluminum hous-
ing. The connections are to be used in accordance with the labeled direc-
tion of flow, in order to obtain an optimum cooling effect.
CAUTION!
The following points must be observed for the cooler:
-
The maximum pressure resistance can be found in the data sheet of
your VECTOPOWER
®
.
-
The maximum pressure against the environment must not exceed
the limit values given in the data sheet either.
-
To prevent corrosion and algae formation, a corresponding glycol
additive must be used. See the information in the data sheet.
-
Due to the fine cooling ducts, there must not be any dirt in the
cooling water circuit. An appropriate filter must be provided.
-
Ensure sufficient cooling. A lower flow temperature and a lower
ambient temperature allow a longer service life.
-
Prevent the liquid coolant from freezing in the VECTOPOWER
®
de-
vice. This can destroy the cooler and cause coolant to escape.
-
No pressure above the pressure resistance specified in the data
sheet must be present, in order to maintain a sufficient reserve
from the test pressure. Otherwise, the cooler can also be destroyed
and cooling liquid can escape.