VP5000-DC/DC60, VP5000-DC/DC200-HL
Product description
Last edited 2019-02-08
by Sonja Scheunert
Filename
VP5000_DCDC60_200-HL_installation_manual_v1-4en.docx
60 / 173
•
“MS" denotes the direction master -> slave.
•
“SM" denotes the direction slave -> master.
Examples:
•
The pin "VBIn_MS" designates the signal input of the VECTOPOWER from the higher-level
VECTONUM control.
•
The pin "VBIn_SM" designates the signal output of the VECTOPOWER to the higher-level
VECTONUM control.
Figure 36: Wiring diagram for a VECTOBUS system [ST3]
Characteristic curves for current, voltage, and power
3.9
3.9.1
VECTOPOWER VP5000-DC/DC60
The following characteristic curves indicate the output voltage and output current under the
following conditions:
•
Ambient temperature 35 °C / 95 °F with sufficient coolant flow.
•
DC link voltage [DC+/-] 650 V DC.
•
Use as a buck converter.
See chapter 3.10 Product description, Characteristic curves for derating.