![AR 10052381 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/ar/10052381/10052381_operating-and-service-manual_2962299037.webp)
Model 125W1000A
Rev A
15
2.6.1.3
Connector J5
Notes:
Lines 3, 4:
Su3.3 Vdc via a 10kOhm pull-up resistor
Lines 1-4:
Guaranteed operation up to +30 Vdc
Lines 3, 4:
0 Vdc or +3.3 Vdc
TTL Inputs & OD Outputs:
Guaranteed operation up to +5 Vdc
TTL
= Digital
OD
= Open Drain
Indicate NO ACTION STATE for TTL Inputs as HIGH (
H
) or LOW (
L
)
Indicate required TTL output state as HIGH (
H
) or LOW (
L
)
Indicate required OD output state as Floating (
F
) or Grounded (
G
)
Control
Lines
Select Function
input or output
Control States
Defined in section 4
Fault?
= Yes
General Description
Add fault description in Sec 6
Add non-fault description in section 7
TT
L
In
TTL
Out
OD
Out
Pwr OFF
RF OFF
Pwr ON
RF OFF
Pwr ON
RF ON
J5 – 1
J5 – 2
F
G
G
PS2 On/Off
J5 – 3
J5 – 4
J5 – 5
G
G
F
PS1 Enable
J5 – 6
L
L
H
A1 Inhibit
J5 – 7
J5 – 8
J5 – 9
H
Amp Fault, A2-1
J5 – 10
H
Amp Fault, A2-1
J5 – 11
J5 – 12
J5 – 13
J5 – 14
J5 – 15
J5 – 16
J5 – 17
J5 – 18
J5 – 19
J5 – 20
J5 – 21
J5 – 22
L
PS2 Thermal Fault
J5 – 23
J5 – 24
H
H
Thermal Fault, A2
J5 – 25
J5 – 26
J5 – 27
J5 – 28
L
PS2 DC Fault
J5 – 29
H
PS1 DC Fault
J5 – 30
L
L
Interlock
J5 – 31
J5 – 32
J5 – 33
+3.3Vdc
J5 – 34
Ground
Содержание 10052381