![AR 10051217 Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/ar/10051217/10051217_operating-and-service-manual_2962298052.webp)
Model 2000S1G2z8
28
Rev A
2.8.3.3
Connector J5
Notes:
Lines 3, 4:
Su3.3 Vdc via a 10kOhm pull-up resistor
Lines 1-4:
Guaranteed operation up to +30 Vdc
Lines 3, 4:
0 Vdc or +3.3 Vdc
TTL Inputs & OD Outputs:
Guaranteed operation up to +5 Vdc
TTL
= Digital
OD
= Open Drain
Indicate NO ACTION STATE for TTL Inputs as HIGH (
H
) or LOW (
L
)
Indicate required TTL output state as HIGH (
H
) or LOW (
L
)
Indicate required OD output state as Floating (
F
) or Grounded (
G
)
Control
Lines
Select Function
input or output
Control States
Defined in section 4
Fault?
= Yes
General Description
Add fault description in Sec 6
Add non-fault description in section 7
TT
L
In
TTL
Out
OD
Out
Pwr OFF
RF OFF
Pwr ON
RF OFF
Pwr ON
RF ON
J5 – 1
G
G
F
PS4 On/Off
J5 – 2
G
G
F
PS5 On/Off
J5 – 3
J5 – 4
J5 – 5
J5 – 6
J5 – 7
J5 – 8
J5 – 9
H
Amp Fault, A11
J5 – 10
H
Amp Fault, A12
J5 – 11
J5 – 12
H
Amp Fault, A33
J5 – 13
H
Amp Fault, A34
J5 – 14
H
Amp Fault, A35
J5 – 15
H
Amp Fault, A36
J5 – 16
H
Amp Fault, A37
J5 – 17
H
Amp Fault, A38
J5 – 18
H
Amp Fault, A39
J5 – 19
H
Amp Fault, A40
J5 – 20
J5 – 21
H
H
Thermal Fault, A11
J5 – 22
H
H
Thermal Fault, A12
J5 – 23
J5 – 24
H
H
Thermal Fault, A33
J5 – 25
H
H
Thermal Fault, A34
J5 – 26
H
H
Thermal Fault, A35
J5 – 27
H
H
Thermal Fault, A36
J5 – 28
H
H
Thermal Fault, A37
J5 – 29
H
H
Thermal Fault, A38
J5 – 30
H
H
Thermal Fault, A39
J5 – 31
H
H
Thermal Fault, A40
J5 – 32
J5 – 33
+3.3Vdc
J5 – 34
Ground
Содержание 10051217
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 18: ...Model 2000S1G2z8 iv...
Страница 22: ...Model 2000S1G2z8 4 Rev A...
Страница 85: ...Model 2000S1G2z8 Rev A 61 Figure 4 2 Typical Response at 0 dBm Input...
Страница 86: ...Model 2000S1G2z8 62 Rev A...
Страница 88: ...Model 2000S1G2z8 64 Rev A...
Страница 90: ......