Model 250S1G6
6
Rev D
2.2.2
POWER Switch
The momentary
POWER
switch turns the main power to the amplifier on and off. The status of the green
light-emitting diode (LED) in the switch indicates whether the amplifier’s power is on or off. The main
power supply fans are active when power is on. The graphic display is active as long as the main power
circuit breaker of the amplifier power entry module is on.
1
4
2
3
5
6
Figure 2-1 Digital Control Panel (DCP) Features
Item
Title
Function
1
INHIBIT, LOCAL, REMOTE
Keylock Switch, 3-position; key removal in INHIBIT position only
2
POWER
POWER control with indicator LED
3
DISPLAY (TOUCH SCREEN)
Numerous parameter values and fault messages, plus manual input control
4
ADJUST
Adjust knob to change selected variables
5
RF INPUT
Type N female connector
6
RF OUTPUT
Type N female connector