INSTRUCTIONS FOR SAFE OPERATION 

 

Revised 0517 

HAZARDOUS RF VOLTAGES 

The RF voltages on the center pin of an RF output connector can be 

hazardous. The RF output connector should be connected 

to a load before AC power is applied to the equipment. Do 

not come into contact with the center pin of the RF output 

connector or accessories connected to it. Place the 

equipment in a non-operating condition before disconnecting or 

connecting the load to the RF output connector.  

ACOUSTIC LIMITATIONS 

If equipment noise exceeds 80dB, ear protection is required. 

MAINTENANCE CAUTION 

Adjustment, maintenance, or repair of the equipment must be 

performed only by qualified personnel. Hazardous energy may be 

present while protective covers are removed from the equipment even 

if disconnected from the power source. Contact may result in personal 

injury. Replacement fuses are required to be of specific type and 

current rating. 

ENVIRONMENTAL CONDITIONS 

Unless otherwise stated on the product specification sheet, this 

equipment is designed to be safe under the following environmental 

conditions:  

 

Indoor use 

 

Altitude up to 2000m 

 

Temperature of 5°C to 40°C 

 

Maximum relative humidity 80% for temperatures up to 31°C. 

Decreasing linearly to 50% at 40°C. 

 

Main supply voltage fluctuations not to exceed ± 10% of the 

nominal voltage or minimum and maximum autoranging values. 

 

Pollution degree 2: Normally non-conductive with occasional 

condensation.  While the equipment will not cause hazardous 

condition over this environmental range, its performance may 

vary. 

EQUIPMENT CONTAINING LASERS 

AR Field Probes (FL/PL Series) and Field Analyzers (FA 

Series)  are Class 1 laser products containing embedded 

Class 4 lasers.  Under normal use, the laser radiation is 

completely contained within the fiber optic cables and 

poses no threat of exposure.  Safety interlocks ensure that the laser is 

not activated unless the cables are properly connected.  Always 

exercise caution when using or maintaining laser products.  Do not 

view directly with optical instruments. 

RF ANTENNAS 

 

This equipment (antenna or antenna assembly) may  be heavy, 

requiring two persons to lift. Use caution when installing or 

removing unit. Follow all equipment setup and lifting instructions 

specified in this document. 

 

Ensure connectors are appropriate for intended  operation.  

Connectors are specified in the user manual and product 

specification sheet. 

 

Do not exceed the maximum  RF input level stated in the 

specifications. Refer to the user manual and product specification 

sheet to determine the applicable RF levels. 

 

Excessive RF input could damage the equipment or connectors, 

causing safety hazards.  

 

When in operation, the RF voltages on the antenna elements can 

be hazardous. Do not come into contact with the antenna or 

elements when the RF input connector is connected to a live RF 

source.  

 

To avoid injury to personnel and accidental damage to power 

amplifier or antenna, disable the RF output of power amplifier 

before connecting or disconnecting the input connection to the 

antenna. 

 

Perform periodic inspections of antenna and field probe systems 

to verify calibration due date, proper operation, and overall 

condition of equipment.  

RACK MOUNTED TWT MODELS 

Some TWT models are supplied without the removable enclosure 

offered for benchtop use. These rack-mountable models may be 

supplied with either carry handles or slides and front handles installed.  

Follow all lifting instructions specified in this document and 

installation instructions supplied in the TWT user manual. 

LIFTING INSTRUCTIONS FOR AR EQUIPMENT 

Because most products must be handled 

during distribution, assembly and use, the 

risk of serious injury due to unsafe 

product handling should be a fundamental 

consideration of every user. An 

authoritative guideline  for eliminating 

unwarranted risk of injury caused by 

lifting is provided by the NIOSH Work Practices (Publication #94-

110) available at: 

https://www.cdc.gov/niosh/docs/94-110/pdfs/94-110.pdf

In general, observe the following guidelines for lifting a weight of 50 

lb or more: 

 

Use lifting eye (for floor standing) or side handles (table top) to 

lift unit only. 

 

Use equipment of adequate capacity to lift and support unit. 

 

If using forklift to move unit, be sure forks are long enough to 

extend beyond the side of the unit. 

 

For additional information, follow the link specified above. 

 

Содержание 1000TP8G18 Series

Страница 1: ...Operating and Service Manual 1000TP8G18 Model 10013116 Part Number Serial Number 160 School House Road Souderton PA 18964 215 723 8181 Fax 866 859 0582 www arworld us...

Страница 2: ......

Страница 3: ...llowing European directives Low Voltage Directive 2014 35 EU EMC Directive 2014 30 EU Supplementary Information Safety EN 60215 1 1989 EN 61010 1 2010 EMC EN 61000 6 2 2005 EN61000 6 4 2007 Year Mark...

Страница 4: ......

Страница 5: ...clearance on all vented sides of the equipment to permit the airflow required for proper ventilation Do not restrict airflow into the equipment by blocking any vents or air intakes Restricting airflow...

Страница 6: ...a assembly may be heavy requiring two persons to lift Use caution when installing or removing unit Follow all equipment setup and lifting instructions specified in this document Ensure connectors are...

Страница 7: ...von 10 2 cm 4 in auf allen bel fteten Seiten des Ger ts ein um eine ausreichende Luftzirkulation zu gew hrleisten Beintr chtigen Sie den Luftstrom des Ger ts nicht indem Sie L ftungs ffnungen oder de...

Страница 8: ...allen in diesem Dokument angegebenen Anweisungen zur Anbringung Stellen Sie sicher dass alle Anschl sse f r den beabsichtigten Betrieb geeignet sind Informationen zu den Anschl ssen erhalten Sie im Be...

Страница 9: ...tilation Ne limitez pas le flux d air allant dans l quipement en bloquant tout vent ou entr e d air La restriction du flux d air peut endommager l quipement causer des coupures intermittentes ou des d...

Страница 10: ...dent lorsque vous installez ou retirez l unit Respectez toutes les instructions concernant l installation et le levage de l quipement indiqu es dans ce document Assurez vous que les connecteurs sont a...

Страница 11: ...is voor goede ventilatie mogelijk te maken Belemmer de luchtstroom in het apparaat niet door ventilatieopeningen of luchtinlaten te blokkeren Het belemmeren van de luchtstroom kan leiden tot schade a...

Страница 12: ...nstellen en optillen van de apparatuur die in dit document worden vermeld Zorg ervoor dat de connectoren geschikt zijn voor de beoogde werking De connectoren worden gespecificeerd in de gebruikershand...

Страница 13: ...ications to the machine may have been made use this information only as a guide Carefully compare the unit s actual configuration and operation to the descriptions in this manual before you undertake...

Страница 14: ......

Страница 15: ...quency with Gain set to 100 apply RF drive that will provide rated power This will help indicate if the gain or power is changing and if the traveling wave tube or pre amp needs service Record the fol...

Страница 16: ......

Страница 17: ...Display and Soft Keys 14 3 5 Rear Panel Features 18 3 6 Initial Turn On and Warm up Procedure 19 3 7 Remote IEEE 488 Operation 20 3 8 TWTA General Considerations 25 4 MAINTENANCE 27 4 1 Safety Warnin...

Страница 18: ...50 FIGURES 3 1 Mounting Support Holes 10 3 2 Front Panel Features 13 3 3 Front Panel Display Screens 14 3 4 Rear Panel Features 18 TABLES 3 1 Front Panel Features 13 3 2 Rear Panel Features 18 3 3 Ca...

Страница 19: ...ed for standard 19 inch rack mounting or bench top use The front panel of the rack mountable amplifier is 8 75 inches high and the overall unit is 25 inches deep excluding the rear panel connectors Pr...

Страница 20: ...Model 1000TP8G18 2 Rev 1 5 TEST DATA SHEET A Test Data Sheet for a specific unit is prepared at the time of manufacture and is included with the unit s copy of this manual...

Страница 21: ...orced air cooled broadband traveling wave tube TWT microwave amplifier designed for pulse applications at low to moderate duty fac tors where instantaneous bandwidth and high gain are required A relia...

Страница 22: ...to 90 Delay 300 ns maximum from pulse input to RF 90 Pulse Width Distortion 30 ns maximum 50 points of output pulse width compared to 50 points of input pulse width Pulse Off Isolation 80 dB minimum 9...

Страница 23: ...MS3106F18 115 connector and appropriate mating connector on rear of amplifier as power inlet S6D Duty Cycle 6 Page 3 1000TP8G18 Pulse Amplifier M1 M22 1000 Watts 7 5GHz 18GHz Model Configurations To o...

Страница 24: ......

Страница 25: ...ment in the leveling loop and for reflected power measurement on the HPA interface board With an optional reverse power sample port an additional 10 dB coupler is connected to the reverse port of the...

Страница 26: ...he TWT grid are provided by the Modulator Assembly A23684 101 The high voltage power supply consists of the following the Power Factor Correction module A23683 100 converts line voltage to DC for the...

Страница 27: ...has been unplugged and it has been positively established that the high voltage filter capacitors have been discharged to a known safe level WARNING Safety Ground Improper grounding of this equipment...

Страница 28: ...e unit remove all of the screws holding the front panel to the cabinet Carefully slide the entire amplifier out of the front of the cabinet CAUTION Never rack mount the TWTA using the front panel alon...

Страница 29: ...in much lower total power dissipation 3 2 4 AC Line Power Connections AC line power connection to the amplifier is made at the Power Supply AC inlet J1 which is a female IEC 320 connector A line cord...

Страница 30: ...l protection CAUTION Do not rely on the external interlock for personnel protection The intent of the external interlock feature is to disable the RF output for equipment protection Use proper operati...

Страница 31: ...routines and returns to the previous menu level 6 9 S1 S4 Soft Key push buttons various menu selection functions 10 Display Displays numerous parameter values and fault messages 11 Keylock Switch All...

Страница 32: ...umber of informational screens are programmed It is important for the operator to be able to select the screen with the required information Screen selection is accomplished by pressing an appropriate...

Страница 33: ...will return you to the screen from which the help screen was called Setup Screens From MENU 2 S1 labeled SETUP selects the first of several setup screens SETUP 1 This allows the user to manually shut...

Страница 34: ...um value causes OFF to be selected disabling this alarm In WARNINGS 3 the maximum reverse peak power level is set Note that these are warning levels at which the beep sounds the actual maximum reverse...

Страница 35: ...ults O PLS WIDTH OVER DUTY and EXTERNAL INHIBIT will turn off RF while the fault is being displayed on the screen HV will remain on during these faults Once the fault is corrected the fault will clear...

Страница 36: ...NOTE 6 FWD SAMPLE OUT Type N female connector see NOTE 7 RF OUT WRD 750 Waveguide WRD 650 in certain configurations 8 EXTERNAL INTERLOCK SWITCH CONTROL Connector to remote temperature switch protecti...

Страница 37: ...expire Line three will indicate OFF READY CAUTION Do not allow the TWTA to remain in STANDBY for extended periods of time If the TWTA will not be used in the OPERATE mode within an hour shut the TWTA...

Страница 38: ...arameter measurements system faults gain adjustment and control unit status The Power Save mode Sleep Mode provides remote capability to control the TWT heater filament and to lower the amplifier stan...

Страница 39: ...everse power out W Peak watts Pr W Pk RDPRD Returns reverse power out dBm Average dBm Pr dBm Avg RDPRW Returns reverse power out W Average watts Pr W Avg RDDUTY Returns Duty DTY RDPOHIDP Returns over...

Страница 40: ...wrong polarity 50 Last command failed Local system does not have remote enabled 51 Remote system is not ready to accept commands 901 Assert error invalid table argument 902 Assert error invalid calibr...

Страница 41: ...B Heater time delay expired 5 Under forward power warning 6 Foldback active 7 MSB Inhibit mode x bit Meaning 8 LSB External inhibit 9 Interlock open 10 not used 11 MSB not used w bit Meaning 12 LSB no...

Страница 42: ...auto off time delay 3 2 0 hour heater auto off time delay 4 2 5 hour heater auto off time delay 5 3 0 hour heater auto off time delay Command syntax is in this form command mnemonic parameter carriage...

Страница 43: ...if required Though service life is not improved by periodic operation users experiencing amplifier trip due to body over current may benefit by periodically operating a unit with high voltage and gri...

Страница 44: ...collector or high voltage is applied to the collector but the grid is off This is the normal state after a tube s warm up time just prior to entering the Operate mode In this state the cathode end of...

Страница 45: ...s equipment in particular Never handle the TWT leads or the high voltage connectors unless it has been positively established that the high voltage filter capacitors have been discharged to a known sa...

Страница 46: ...ature Air inlet filter dirty Collector heat sink dirty Inadequate clearance behind TWTA High air inlet temperature Defective fan or fan driver No response when main power turned on Disconnected power...

Страница 47: ...on based on the failure symptom and an understanding of the logic schematic diagrams 4 5 NON REPAIRABLE MODULES The Heater power supply A10010 000 the Grid modulator A23684 101 the HV filter A21458 01...

Страница 48: ...Model 1000TP8G18 30 Rev...

Страница 49: ...cian level servicing It is intended for use by qualified technical personnel who must troubleshoot and repair the TWTA in the field Such repairs are typically limited to replacement of modules or majo...

Страница 50: ...J PSC MODULATOR CONTROL BOARD 1A1A9 A10010 000 HEATER POWER SUPPLY MODULE 1A1A9T1 A09409 000 XFMR HEATER FEEDBACK 1A1A9T2 A09408 000 XFMR HEATER POWER 1A1A10 A21459 021 PWM BOARD FOR TWT 3444 1A1A11 A...

Страница 51: ...dule A23683 100 10 23687 001 LV Power Supply Module A23687 001 10 24830 008 Remote Control Board Foldback only A24830 008 10 25444 001 HPA Interface A25444 001 10 27500 914 1000W Pulsed TWT Amplifier...

Страница 52: ...Model 1000TP8G18 34 Rev...

Страница 53: ...22826 914 Pulsed TWT Power Supply A24830 008 Remote Control Board Foldback A25444 001 HPA interface A27500 914 TWTA 1kW Pulsed IJ Band A27500 918 TWTA 1kW Pulsed IJ Band w optional reverse sample port...

Страница 54: ...ST 3 J2 J10370 000 CONN 37 PIN MALE D SUB PCB RIGHT ANGLE AMP 747252 4 1 J18075 000 MALE SCREW LOCK FOR D SUBMIN CONN AMP 205817 1 1 J4 J5 J18086 000 CONN SMA JACK RECEPTACLE RIGHT ANGLE 0 18GHZ PC MO...

Страница 55: ...53K 1 2W 1 MF 100PPM DALE RN55D 1 R12 R15 R32020 000 TRIMPOT 10K 1 2W 10 CERMET 20T SIDE ADJ BECKMAN 67X 2 U4 U5 U6 U02390 000 IC QUAD COMPARATOR NAT LM139J 3 U7 U03240 000 IC LOW POWER OP AMP NAT LM3...

Страница 56: ...2 E01015 000 EQUALIZER 8 18 GHZ 13PIJ INMET EQTBD 3 1 A1 E01247 000 SSPA IJ BAND 6 0 18GHZ 20DBM 20DB GAIN 35DB VGA CPI CMA6018A3 1 E01535 000 GASKET CONDUCTIVE O RING WRD 650 MDC TBD 1 E01598 000 WAV...

Страница 57: ...TRAIGHT HNL PER ETM DRAWING 1 A2 E01859 000 TWT 7 5 18 0 GHZ 1 5KW PULSED 6 WRD 750 2 DB EQ TELEDYNE MTI 3444L 6 2 DB EQ 1 E20014 000 ATTENUATOR 14DB 2W SUB MINIATURE INMET 18A 14 1 E20066 000 ATTENUA...

Страница 58: ...87 382 POWER BOARD ASSEMBLY PULSED TWTA 1 A6 A21425 021 DIODED CAP ASSY FOR TWT 3444L 1 A12 A21458 005 CAPACITOR BANK 1 A7 A21458 010 HV FILTER 1 A10 A21459 021 PWM BOARD FOR TWT 3444 1 A1 A23280 000...

Страница 59: ...COMPONENTS 142 0701 301 1 J1 J18180 000 CONN D SUB 15 PIN MALE STRAIGHT PCB MOUNT POSITRONIC MD15M3000 1 J31014 000 SPRING LATCH KIT D SUB AMPHENOL 17 529 2 Q1 Q3 Q22222 000 TRANSISTOR NPN 2N2222A TO...

Страница 60: ...8 102 103 105 107 108 109 110 111 112 113 114 115 116 117 121 125 132 167 C31036 000 CAP 0 1MF 100VDC 10 CER 1 FAILURE KEMET CKR06 SERIES W V OPTION 61 C12 C14 C17 C18 C19 C21 C27 C29 C31 C34 C36 C38...

Страница 61: ...XIAL 100PPM DALE CMF 50 RN50C1002F 7 R17 R18 R19 R20 R21 R23 R25 R28 R31 R42 R43 R46 R30140 000 RES 1K 1 8W 1 MF 50PPM DALE RN50C 12 R13 R14 R24 R26 R27 R29 R32 R37 R38 R39 R47 R100 R31164 000 RES 100...

Страница 62: ...3 U4 U49 U58 U28032 000 IC QUAD 2 INPUT OR 74HC32 SSD 3 U44 U46 U28040 000 IC 12 BIT DECADE COUNTER 74HCT4040 SSD 2 U5 U13 U14 U23 U25 U33 U50 U28074 000 IC DUAL D FLIP FLOP W RESET 74HC74 SSD 7 U2 U...

Страница 63: ...C FOR TWT MTI 3444L 1 A6 A23692 000 INSULATED FAN DRIVER 1 A3 A25444 001 HPA INTERFACE BOARD 200UM GLASS FIBERS 1 A10 A27501 902 CABINET ASSY 400 C SINGLE PHASE LITTON TWT AR 1 A4 A27509 301 HPA CONTR...

Страница 64: ...C FOR TWT MTI 3444L 1 A6 A23692 000 INSULATED FAN DRIVER 1 A3 A25444 001 HPA INTERFACE BOARD 200UM GLASS FIBERS 1 A10 A27501 903 CABINET ASSY 400 C SINGLE PHASE LITTON TWT AR 1 A4 A27509 301 HPA CONTR...

Страница 65: ...C FOR TWT MTI 3444L E01859 000 1 A6 A23692 000 INSULATED FAN DRIVER 1 A3 A25444 001 HPA INTERFACE BOARD 200UM GLASS FIBERS 1 A10 A27501 005 CABINET ASSY 500 SC SINGLE PHASE AR 1 A4 A27509 301 HPA CONT...

Страница 66: ...03 06 1032 1 J00034 000 CONN HOUSING FEMALE 03 PIN MOLEX 5197 N 10 01 3036 1 J00040 000 CONN PIN SOCKET 4 PIN FEM STR MOLEX 03 09 1041 1 J00046 000 CONN HOUSING FEMALE 4 PIN 0 1SPACING 7880 SERIES MOL...

Страница 67: ...ESSION CORE 0 25HOLE WITH CASE FAIR RITE 0443164251 1 N24373 000 CONNECTOR COVER 1 XA11 N27418 000 COVER TERMINAL EMI FILTER 2 N27728 000 HPA INTERFACE SHIELD 1 S2 S3 S25002 000 SWITCH PUSHBUTTON SPDT...

Страница 68: ...ON D McCLURE 1040 1041 DIM F 80 1042 DIM A 80 1050 CLEAR SCREEN 1060 INPUT INPUT COMMAND TO SEND TO POWER SUPPLY EXIT TO QUIT A 1070 IF A EXIT THEN 1130 1080 OUTPUT 701 A 1090 IF A 1 2 RD THEN GOTO 10...

Страница 69: ...e off time and allows use of peripheral components connectors cables or waveguide directional couplers loads and so forth with lower CW power ratings AR s pulse TWTAs are designed specifically for pul...

Страница 70: ...al rise and fall times in the low or sub nanosecond range If the RF input remains and the TTL level goes low logical 0 then the RF output would reach 10 of its prior on value within 300ns Delay The ob...

Страница 71: ...specification defines the maximum percentage of the time that the TTL level input can be allowed to remain positive logical 1 For example if the chosen PRF is 5 kHz then the maximum allowable TTL inpu...

Страница 72: ...proper operation of these Pulse TWTAs though TWTA design prevents damage when these conditions are exceeded Be sure to refer to the appropriate AR Data Sheet for detailed amplifier specifications Use...

Страница 73: ...cover If the security label is removed and or cut the warranty of the module will be voided Vacuum tubes in the L series amplifiers traveling wave tubes in TWT amplifiers and power heads will be free...

Страница 74: ......

Отзывы: