Model 1000TP8G18
16
Rev -
during extended periods of
remote
operation to improve tube life, by turning off the filaments (Sleep Mode
activated). This eliminates excessive STANDBY hours on the TWTs while still permitting remote capability
to turn on the amplifier.
After activating the Sleep Mode:
Screen will display
Cooling On
while heaters cool down.
System Off
notifies user that the amplifier is in
Sleep Mode
To de-Activate Sleep Mode:
Press the ON soft key to de-activate Sleep Mode. Amplifier will return to MENU 1. When de-activating the
Sleep Mode the heaters will require approximately a 5 minute heater time delay. Wait the full 5 minutes prior
to selecting OPERATE.
Warnings Screens
- From MENU 3, S1 (labeled WARNINGS) selects WARNINGS 1 which allows the
operator to enter the maximum forward peak power. The existing value is between brackets[ ]; pressing SET
puts arrows >< around the value, indicating that the adjust knob is active. The effect of the warning setpoint is
as follows: if the forward peak power exceeds the setpoint, the audible alarm will sound (if configured in
SETUP 5).
This warning will be repeated every thirty seconds until the over forward power condition is cleared. In
addition, a warning message will appear on line 3 (the status line) of MENU 1. In the event that the alarm is
heard, the operator should go to MENU 1 to determine the cause.
Pressing MORE brings up WARNINGS 2, which allows the under forward peak power setpoint to be entered.
Adjusting this to the minimum value causes -OFF- to be selected, disabling this alarm.
In WARNINGS 3, the maximum reverse peak power level is set. Note that these are warning levels at which
the beep sounds; the actual maximum reverse power level that generates a system fault is set in hardware in
the TWT power supply HPA Logic and Control module.
MORE brings up WARNINGS 4, which allows input of the maximum cabinet temperature. Entering this
parameter is performed as above.
MORE brings up WARNINGS 5, identical to the previous screen except that it deals with the maximum TWT
collector block temperature. If either parameter exceeds the setpoint, the audible alarm will sound every 30
seconds (if configured), and a warning message will appear on line 3 of MENU 1.
MORE brings up WARNINGS 6, which permits setting the maximum helix current. Any helix current above
this setpoint will result in an audible alarm (if configured), repeated every 30 seconds; and a warning message
is displayed on the status line of MENU 1.
Pressing MORE again returns display to WARNINGS 1. As before, pressing EXIT from any of the warnings
screens returns display to MENU 3.
Info Screen
- From MENU 3, S2 (labeled INFO) selects a screen that displays the RF sample port calibration
factors at various frequencies across the band. In addition, this screen displays the model number, serial
number and firmware revision information that may be required by a service representative when providing
technical assistance. The EXIT key returns the display to MENU 2.
Event Screen
- From MENU 5, S2 (labeled EVENT) provides a display of events logged by the control
system. These events include AC power-up, heater warm-up, change from standby to operate, faults, and