ITEM

QUANTITY

PART NUMBER

DESCRIPTION

1

1

38256

NRV 1044 CARBON; 1044 CARBON/KDF 

38257

NRV 1054 CARBON; 1054 CARBON/KDF

TANK WITH BASE

2

1

RISER PIPE ASSEMBLY

3

1

19567

DISTRIBUTOR ADAPTER KIT

4

1

19574

HEAD 2in CENTER

6

2

19593

COUPLER ADAPTER

7

2

17961

119 O-RING

8

2

19575

CLIP

9

2

17966

SCREW SLOT IND HEX 8-18 X 5/8

10

1

17557

BYPASS VALVE

11

1

17862

PLUMBING YOKE 1IN SWEAT

NRV 1044 CARBON
NRV 1054 CARBON

PARTS LIST & EXPLODED VIEWS FOR:

NRV 1044 CARBON; 1044 CARBON/KDF

2

7

10

3

4

5

8

9

NRV 1054 CARBON; 1054 CARBON/KDF

18623
18851

11

6

1

5

2

70273

O-RING 29.5mm ID

2 BOXES

38850

CARBON, 1 CU. FT. BOX

QUANTITY

PART NUMBER

DESCRIPTION

1 BAG

17732

GRAVEL UNDERBEDDING, 50 LB. BAG

REPLACEMENT MEDIA

*NRV 1044 CARBON USES 1.40 CU.FT. OF CARBON AND 15 LBS OF GRAVEL UNDERBEDDING. 

NRV 1054 CARBON USES 1.85 CU.FT. OF CARBON AND 15 LBS OF GRAVEL UNDERBEDDING.
NRV 1044 CARBON/KDF USES 1.30 CU.FT. OF CARBON, 0.1 CU.FT. OF KDF, AND 15 LBS OF GRAVEL UNDERBEDDING.
NRV 1054 CARBON/KDF USES 1.75 CU.FT. OF CARBON, 0.1 CU.FT. OF KDF, AND 15 LBS OF GRAVEL UNDERBEDDING.

NRV 1044 CARBON/KDF
NRV 1054 CARBON/KDF

1 BAG

19099

KDF, 0.1 CU. FT. BAG

Содержание ProSystems NRV 1044

Страница 1: ... requirements only The NRV Whole House Carbon Filter is tested and certified by WQA to NSF ANSI 372 for low lead compliance ProSystems a Division of Aquion Inc 101 S Gary Avenue Roselle Illinois 60172 1 800 811 3489 www prosystemswater com This product is manufactured in an ISO 9001 2008 certified facility NRV WHOLE HOUSE FILTER ...

Страница 2: ...TABLE OF CONTENTS 2 System Information 3 Pre Installation Instructions 3 Installation Instructions 4 5 Exploded Views and Parts Lists 6 7 Troubleshooting Guide 8 Warranty Information 9 ...

Страница 3: ...ally become exhausted and will need to be replaced Carbon is available in cubic foot bags as part number 38850 KDF is available in 1 10 cubic foot bags as part number 19099 PRE INSTALLATION INSTRUCTIONS Do not install this system where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system CARBON KDF models are intended for the removal of s...

Страница 4: ...e If the system is located outdoors protect the unit from direct sunlight Direct sunlight can damage the fiberglass and other system components If necessary build a box or shed Note The system can only be installed outdoors in climates that do not reach freezing levels 5 TURN OFF THE WATER AND DRAIN THE PLUMBING Turn off the water at the meter or the pressure tank Drain all the pipes Do not sweat ...

Страница 5: ...f the valve 8 TURN ON THE WATER AND TEST FOR LEAKS AND FLUSH THE PLUMBING Before turning the water back on place the system in the bypass position then close all of the faucets except one cold water tap from a bath tub Turn the water on slowly and allow the water to flow out the bath tub for several minutes to remove any dirt solder glue etc from the plumbing system Once the water runs clear turn ...

Страница 6: ...BON 1044 CARBON KDF 2 7 10 3 4 5 8 9 NRV 1054 CARBON 1054 CARBON KDF 18623 18851 11 6 1 5 2 70273 O RING 29 5mm ID 2 BOXES 38850 CARBON 1 CU FT BOX QUANTITY PART NUMBER DESCRIPTION 1 BAG 17732 GRAVEL UNDERBEDDING 50 LB BAG REPLACEMENT MEDIA NRV 1044 CARBON USES 1 40 CU FT OF CARBON AND 15 LBS OF GRAVEL UNDERBEDDING NRV 1054 CARBON USES 1 85 CU FT OF CARBON AND 15 LBS OF GRAVEL UNDERBEDDING NRV 104...

Страница 7: ...7 ALL DIMENSION ARE IN INCHES TOLERANCE 0 25 A B 2 0 C TANK SIZE DIMENSION A DIMENSION B DIMENSION C 10 x 44 10 x 54 46 1 4 56 47 3 4 57 1 2 10 1 2 10 1 2 SYSTEM NUMBER 35463 35479 35464 35480 ...

Страница 8: ...d OUTLET in correct orientation Flush pipes of filter media add replacement filter media lost from system 3 Loss of water pressure 1 Low pressure to the system 1 Bypass the system to confirm the problem If the problem still exists after bypass it is not related to the filter Have your water distribution system checked If the problem is resolved after bypass check the following causes 2 Mineral or ...

Страница 9: ...purchase of the item which is claimed to be defective and a brief description of the problem detected ProSystems Water Treatment Systems is not responsible under this Limited Warranty for any cost incurred for shipping or transportation in connection with the return of the part s or product s Repair or Replacement Upon receipt of the product and warranty claim ProSystems Water Treatment Systems wi...

Страница 10: ...10 NOTES ...

Страница 11: ...11 NOTES ...

Страница 12: ...ProSystems a Division of Aquion Inc 101S Gary Avenue Roselle Illinois 60172 800 811 3489 2016 Aquion Inc ...

Отзывы: