ELECTRONIC CONTROL PANEL 

 

Page 7 

  

Picture 6

 

 

symbol 

button 

function 

 

SCROLL 

to advance to the next 

parameter 

 

UP 

to increase the value of the 

parameter 

 

DOWN 

to decrease the value of the 

parameter 

 

POWER-UP 

 
After power-up, the power LED will light up and the display 
will show the installed software version, f.e.: 
 
 
 
After  5  seconds,  it  will  automatically  revert  back  to  the 
service mode. 
 

POWER FAILURE 

 

In  the  event  of  a  power  failure,  the  program  will  remain 
stored in the NOVRAM® during an undefined period, while 
an  incorporated  SuperCap  (capacitor)  will  maintain  the 
correct  time  of  day  during  a  period  of  several  hours; 
consequently, in case of prolonged power failure, the time 
of day might not be maintained; if this happens, the time 
of  day will  be  reset  to  8:00  when  the  power  supply  is  re-
established,  while  the  indication  will 

flash

,  indicating  that 

the time of day needs to be set. 

 
 

 

When the power failure occurs during the execution of an 
automatic regeneration, the control valve will remain in its 
last position; when the power supply is re-established, the 
control valve will return to the service position, stay there 
for  60  sec.  and  restart  a  complete  regeneration  from  the 
beginning. 
 

TIMER FAILURE 

 

In  the  event  of  a  timer  failure,  the  display  will  show  the 
message: 
 
 
 
If  powering  off/on  the  water  filter  doesn’t  solve  this 
problem, professional service is required. 
 

SERVICE MODE 

 
In 

service  mode 

the

 

display  shows  the  time  of  day  and  

remaining number of days before the next regeneration: 
 
 

 

 
 
 
 

REGENERATION MODE 

 
In 

regeneration  mode 

the

 

display  shows  the  remaining 

regeneration time and the remaining cycle time: 
 
 
 

The control valve can be 

reset to service mode

 at any time 

by  pressing  the 

scroll 

  button,  as  such  manually 

advancing it through the regeneration cycles. 

 

MANUAL REGENERATION 

 

It is possible to manually initiate a regeneration. 
1.

 

Press the 

scroll

 

 button repeatedly until  the  display 

shows: 

 
 
 

 

If  the  control  valve  is  left  in  this  position,  the 
countdown timer will countdown to 0 sec and 

start 

a regeneration.

 

 

To  cancel  this  mode,  press  the 

scroll

 

  button 

before the countdown timer has reached 0 sec; the 
control valve will return to the service mode. 

2.

 

Press  the 

scroll

 

  button  again  if  you  want  to 

manually  advance  the  control  valve  to  the  next 
regeneration cycle. 

 

DRIVE MOTOR SPEED 

 

The drive motor of the control valve, that drives the valve 
body to its different regeneration positions, will start-up at 
low speed to reduce its noise level. To increase the speed 
of  the  drive  motor,  simply  press  the 

scroll

 

  button  as 

soon as the drive motor is activated. 
 

Service Required  

 

 

Rgn:XXX CycY:ZZZ

 

EZRFTg EZ Rot0.8 

 

 8:00

  4 DAY REM 

 

Regen in 10 sec 

 

20:51  4 DAY REM 

Содержание Oxydizer

Страница 1: ... 2012 Aquion Inc TM EN Oxydizer Rev2012 08 T TE EC CH HN NI IC CA AL L M MA AN NU UA AL L Fe Mn H2S WATER FILTER ...

Страница 2: ...l panel Page 7 Maintenance Page 9 Hydraulic flow diagrams O2xydizer Page 10 Hydraulic flow diagrams O2xydizerPRO Page 11 Troubleshooting Page 12 Electrical wiring diagrams Page 13 Default parameter settings Page 14 Exploded view System Page 16 Exploded view Timer head Page 18 Exploded view Valve body O2xydizer Page 20 Exploded view Valve body O2xydizerPRO Page 22 Technical Specifications Page 24 ...

Страница 3: ...ly be undertaken by a competent person aware of the local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the water filter make sure to check it for any externally visible damage do not install or use when damaged Use a hand truck to transport the water filter To prevent accident or injury do not hoist the water filter over your ...

Страница 4: ...sure the performance may be affected negatively if installed on a well verify that the well pump is powerful enough to provide sufficient flow rate for the regeneration check water pressure regularly install a pressure reducer ahead of the water filter if necessary OPERATING TEMPERATURE min 4 max 38 C do not install the water filter in an environment where high ambient temperatures e g unvented bo...

Страница 5: ...ter inlet of water filter untreated water outlet of water filter treated water house application treated water 1 Install the 3 valve bypass system 2 Screw the connection kit with nuts onto the in out ports on the control valve make sure to install the gasket seals Tighten the nuts firmly by hand 3 Connect the 3 valve bypass system to the nipples on the in and out port of the control valve 4 Connec...

Страница 6: ...se the tap 7 Check the water filter and all hydraulic connections for leaks O2xydizer PRO only during the passage through the compressed air chamber the treated water will get highly oxygenated As a consequence it may become slightly non transparent milky appearance when it flows from the tap into a glass This is totally harmless for the quality of the treated water and will disappear rapidly if t...

Страница 7: ...ilure the display will show the message If powering off on the water filter doesn t solve this problem professional service is required SERVICE MODE In service mode the display shows the time of day and remaining number of days before the next regeneration REGENERATION MODE In regeneration mode the display shows the remaining regeneration time and the remaining cycle time The control valve can be ...

Страница 8: ... of day 3 Press the scroll button again the display will show Press the up or down button to set the number of days between regenerations The absorption capacity of the O2xydizer systems mainly depends on the daily water usage and the Iron Manganese content in the water many other factors may also have a significant impact on the absorption capacity Therefore it is recommend to regenerate the syst...

Страница 9: ...ASS optional Picture 7 a SERVICE POSITION inlet valve to water filter is OPEN outlet valve from water filter is OPEN Picture 7 b BYPASS POSITION inlet valve to water filter is CLOSED outlet valve from water filter is CLOSED Picture 7 c MAINTENANCE POSITION inlet valve to water filter is OPEN outlet valve from water filter is CLOSED WITH 3 VALVE BYPASS SYSTEM not included Picture 8 a SERVICE POSITI...

Страница 10: ...HYDRAULIC FLOW DIAGRAMS O2xydizer Page 10 SERVICE BACKWASH PURGE ...

Страница 11: ...HYDRAULIC FLOW DIAGRAMS O2xydizerPRO Page 11 SERVICE BACKWASH AIR INTAKE PURGE ...

Страница 12: ...ation Faulty electrical supply Verify electrical service fuse transformer Defective PCB Replace PCB Defective drive motor Replace drive motor Regeneration frequency not programmed Program regeneration frequency Loss of water pressure Build up of impurities in pressure tank Clean filter medium and control valve increase regeneration frequency Plugged lower and or upper distributor Verify that distr...

Страница 13: ...ELECTRICAL WIRING DIAGRAMS Page 13 position switches power lead drive motor key pad ...

Страница 14: ...Page 14 Model O2xydizer O2xydizer PRO Filter medium quantity Cuft Ltr 1 28 2 56 1 28 2 56 Interval days 4 4 4 4 Cycle 1 BACKWASH min 10 10 10 10 Cycle 2 AIR INTAKE min 0 0 10 15 Cycle 3 PURGE min 2 2 2 2 Regen 0 00 0 00 0 00 0 00 ...

Страница 15: ...Page 15 ...

Страница 16: ...EXPLODED VIEW SYSTEM Page 16 ...

Страница 17: ...iser tube assembly to be cut to length 4 28 298 11 Transformer 230 24V 50 Hz 24VA EuroT plug 5 287 166 Top distributor 6a 2400TF JN AUX Control valve O2xydizer 1 Cuft 2400TF JQ AUX Control valve O2xydizer 2 Cuft 6b 2400TF J5N AUX AIR Control valve O2xydizerPRO 1 Cuft 2400TF J5Q AUX AIR Control valve O2xydizerPRO 2 Cuft 7 568 303 6 Connection kit 3 4 BSP male Recommended Spare Part ...

Страница 18: ...EXPLODED VIEW TIMER HEAD Page 18 ...

Страница 19: ...or assy 2x 9 28 245 4 Cable clamp 10 71502 Strain relief power lead 11 72261 Drive motor 12 568 227 2 Worm 13 19 48 Retaining ring 14 70965 Switch cam 15 568 386 Bracket micro switches 16 568 310 Gear switch cam 17 15 184 7 Locking screw switch cam 18 15 173 12 Screw micro switches 2x 19 72451 Micro switch assy 20 71679 Cable set drive motor 21 15 102 Screw PCB 2x 22 72703 Printed Circuit Board 23...

Страница 20: ...EXPLODED VIEW VALVE BODY O2xydizer Page 20 ...

Страница 21: ...Gasket 15 413 62 Spring float valve 16 568 270 4 Float valve 17 568 274 5 Injector green 18 186 118 O ring plug small 19 541 273 Plug small 20 541 254 Spring clip plug small 21 570 251 Gasket riser 22 568 334 Riser insert 23 185 214 1 O ring riser tube 24 185 337 1 O ring tank 25 541 232 Adapter ring 26 15 207 12 Screw adapter ring 2x 27 568 216 3 Packing gland nut 28 185 211 1 O ring packing glan...

Страница 22: ...EXPLODED VIEW VALVE BODY O2xydizerPRO Page 22 ...

Страница 23: ...green 18 186 118 O ring plug small 19 541 273 Plug small 20 541 254 Spring clip plug small 21 570 251 Gasket riser 22 568 334 Riser insert 23 185 214 1 O ring riser tube 24 185 337 1 O ring tank 25 541 232 Adapter ring 26 15 207 12 Screw adapter ring 2x 27 568 216 3 Packing gland nut 28 185 211 1 O ring packing gland nut 29 186 115 O ring worm drive shaft 2x 30 568 208 2 Worm drive shaft 31 14 43 ...

Страница 24: ...PRO Filter medium quantity Cuft Ltr 1 28 2 56 1 28 2 56 Recommended max service flow m 3 hr 2 1 1 1 6 1 1 1 6 Nominal backwash flow flow to drain Ltr min 23 30 23 30 Rinse water usage per regeneration Ltr 272 364 352 444 2 continuous service flow rates higher up to x2 short period peak flow rates are possible Dimensions and weights Model O2xydizer O2xydizer PRO Filter medium quantity Cuft Ltr 1 28...

Страница 25: ...Page 25 ...

Страница 26: ......

Страница 27: ......

Страница 28: ......

Отзывы: