OPERATING CONDITIONS & REQUIREMENTS
Page 4
APPLICATION LIMITATIONS:
Dissolved Oxygen (D.O.)
:
O
2
xydizer: min. 15% of Iron + Manganese content
O
2
xydizer
PRO
: N/A
pH
: for Iron removal: 6,8 - 9,0
for Manganese removal: 8,0 - 9,0
for Iron & Manganese removal: 8,0 - 8,5
maximum contaminant content
:
O
2
xydizer
O
2
xydizer
PRO
Iron (Fe
2+
)
3 mg/L
(1)
15 mg/L
Manganese (Mn
2+
)
2 mg/L
(1)
2 mg/L
Hydrogen Sulfide (H
2
S)
0,1 mg/L
(2)
5 mg/L
(1)
largely depends on the D.O. content.
(2)
max. level recommended by WHO.
organic matter
: max. 4,0 mg/L; higher level may hinder the correct
operation of the system.
chlorine
: max. 1,0 mg/L
iron bacteria
: if iron bacteria are present, frequent service may be
necessary, while the life of the system may be limited; by properly
controlling the iron bacteria with chlorine or another approved method of
bacterial reduction, the system will function properly.
OPERATING PRESSURE: min. 1,4 / max. 8,3 bar
this system is configured to perform optimally at an operating pressure of
3 bar (±½ bar); in case of a higher operating pressure the performance
may be affected negatively!
if installed on a well, verify that the well pump is powerful enough to
provide sufficient flow rate for the regeneration.
check water pressure regularly.
install a pressure reducer ahead of the water filter if necessary.
OPERATING TEMPERATURE: min. 4 / max. 38 °C
do not install the water filter in an environment where high ambient
temperatures (e.g. unvented boiler house) or freezing temperatures can
occur.
the water filter cannot be exposed to outdoor elements, such as direct
sunlight or atmospheric precipitation.
do not install the water filter too close to a water heater; keep at least 3
m of piping between the outlet of the water filter and the inlet of the
water heater; water heaters can sometimes transmit heat back down the
cold pipe into the control valve; always install a check valve at the outlet
of the water filter.
ELECTRICAL CONNECTION: 230V-50Hz
this water filter only works on 24VAC; it is equipped with a 230/24V-50Hz
transformer; always use it in combination with the supplied transformer.
make sure to plug the transformer into a power outlet, which is installed
in a dry location, with the proper rating and over-current protection.
Содержание Oxydizer
Страница 10: ...HYDRAULIC FLOW DIAGRAMS O2xydizer Page 10 SERVICE BACKWASH PURGE ...
Страница 11: ...HYDRAULIC FLOW DIAGRAMS O2xydizerPRO Page 11 SERVICE BACKWASH AIR INTAKE PURGE ...
Страница 13: ...ELECTRICAL WIRING DIAGRAMS Page 13 position switches power lead drive motor key pad ...
Страница 15: ...Page 15 ...
Страница 16: ...EXPLODED VIEW SYSTEM Page 16 ...
Страница 18: ...EXPLODED VIEW TIMER HEAD Page 18 ...
Страница 20: ...EXPLODED VIEW VALVE BODY O2xydizer Page 20 ...
Страница 22: ...EXPLODED VIEW VALVE BODY O2xydizerPRO Page 22 ...
Страница 25: ...Page 25 ...
Страница 26: ......
Страница 27: ......
Страница 28: ......