Unpacking the ComAir 20T unit. 

 
1. Carefully remove the parts from the package. The lamps are fragile and proper care must be taken 
when removing packaging that is placed around them. 
  
2. Do not touch the lamps with your bare hands, as oils from your hands can create “hot spots” which 
reduce the lamp life. In case of contact with the lamp, wipe the lamp clean with a soft cloth dampened 
with rubbing alcohol. 
 
3. Check the parts list below to make sure you have all of them: 
 
• One ComAir 20T Main unit 
 

Ozone Lamp 

 

Germicidal Lamp 

 

Lamp Shield 

 

Air Flow PCB 

• Four self-tapping screws 
• Installation/owners manual 
• Warranty card 
 
 

COMAIR 20T INSTALLATION  
Assembly: 

 

1. Remove the four screws from the cover of the unit and remove the cover. 
2. See figures on page 11 and 13 for locations of components. Install lamp shield by using the hardware 
that is attached to the main unit. Attach shield to main unit and tighten the two nuts. 
3. Install Ozone Lamp: Loosen the lamp lock nut from the lamp holder by turning it counterclockwise and 
remove. 
4. Remove the metal washer and the rubber bushing from the lamp holder and install the rubber 
bushing on the lamp. 
5. Slide the lamp into the lamp opening. Handle lamp by the end cap. 
6. Re-install the metal washer and lamp lock nut. Carefully tighten the lamp lock nut. 
7. Connect the lamp connector to the end of the lamp. 
8. Install Germicidal Lamp: Remove nuts and washers from the mounting studs. 
9. Check to be sure that the O-ring is installed around the base of the lamp. Insert lamp into the main 
unit. The two mounting ears on the lamp base should go through the mounting studs. 
10. Install the plastic washers and nuts. Tighten nuts snugly, but do not over tighten. 
11. Connect the lamp connector. 
12. Insert the Air Flow PC Board into the hole on the bottom of the unit.  The sensor connector is keyed 
so it can only go in one way. 

 

 

Содержание OptiPure ComAir 20T

Страница 1: ...fication System Installation Owners Manual OptiPure a Division of Aquion Inc 101 S Gary Ave Suite A Roselle IL 60172 972 881 9797 e mail info optipure net www optipurewater com Copyright 2018 OptiPure...

Страница 2: ...ComAir 20T Unit 3 Important Safety Instructions 3 Unpacking Your ComAir 20T Unit 4 ComAir 20T Installation 4 Adjusting the Ozone Output Level 6 Accessories 7 Maintenance Requirements 10 Specification...

Страница 3: ...nable smells that may be present in your business or residence To receive optimal benefit and performance from the unit your furnace or air conditioner fan should be in the ON position at all times IM...

Страница 4: ...that is attached to the main unit Attach shield to main unit and tighten the two nuts 3 Install Ozone Lamp Loosen the lamp lock nut from the lamp holder by turning it counterclockwise and remove 4 Re...

Страница 5: ...board and secure cover to main chassis Assemble using the four screws provided 7 Plug the power cord into a non switched 90VAC 277 VAC outlet Note On initial startup the Power Air Germicidal Ozone an...

Страница 6: ...ttings from low to boost and then back to low The unit will default to the low setting on initial power up LOW Use with HVAC units with capacities between 5 and 8 75 Tons or in spaces with 1500 to 260...

Страница 7: ...as a computer network cable Plug one end of the cable into the end of the remote display see figure on next page and the other end into the connector labeled Remote located on the PC Board mounted in...

Страница 8: ...sis of the ComAir 20T The remote Ozone sensor supplied by OptiPure should be mounted in a HVAC duct as close to a supply register as possible The sensor box requires a hole to be punched in the duct f...

Страница 9: ...9 Remote Cable Connection Ozone Sensor Connections Ozone Sensor Switches...

Страница 10: ...e hot spots which reduce the lamp life Handle by either the end caps or use a soft cloth In case of contact with the lamp wipe the lamp clean with a soft cloth dampened with rubbing alcohol CLEANING T...

Страница 11: ...back into the lamp opening Handle lamp by the end cap 9 Re install the metal washer and lamp lock nut Carefully tighten the lamp lock nut 10 Reconnect the lamp connector to the end of the lamp 11 Germ...

Страница 12: ...e on the circuit board If fuse is blown replace For the following tests make sure there is no air flow across unit Unplug the power cord for 1 to 2 minutes Plug the power cord back in The Air light wi...

Страница 13: ...13 Ozone Lamp Air Flow Sensor Germicidal Lamp...

Страница 14: ...rvice requirements as outlined in the I O manual Obtaining Service Under the Warranty Any product and or part not performing satisfactorily may be returned to OptiPure for evaluation A Return Goods Au...

Страница 15: ...from such a defect Some states do not allow the exclusion or limitation of incidental or consequential damages so that above limitation or exclusion may not apply to you Legal Remedies of Purchaser Th...

Отзывы: