Aquion EFP10 Скачать руководство пользователя страница 5

INSTALLATION 

 

 

Page 5 

EN - English

 

WATER SUPPLY ADAPTOR 

 

 

An adaptor is supplied with the water filtration system 

for the connection to the water supply inside the house; at 
the inlet side (connection to the plumbing inside the house) 
it has a 3/8” BSP female thread; the corresponding thread 
on the plumbing inside the house should be 3/8” BSP male.  

 

 

For filter cartridge replacement, the water supply to the 

water filtration system needs to be turned off; therefore it 
is recommended to install the water supply adaptor behind 
a  stop  valve.  Typically  this  can  be  the  stop  valve  that  is 
already  in  place  to  shut  off  the  cold  water  supply  to  the 
main  faucet.  If  the  water  supply  adaptor  can  not  be 
installed  after  this  stop  valve,  we  strongly  recommend  to 
install  a  separate  stop  valve  (not  included  with  this 
product!),  preferably  with  3/8”  BSP  male  thread  at  the 
outlet. 

 

 

Make sure to shut off the water supply to the place of 

installation, before you start any plumbing work. 
 
AFTER  EXISTING  STOP  VALVE  IN  COLD  WATER  SUPPLY  TO 
MAIN FAUCET  
 
1.

 

Remove  the  existing  connection  coming  from  the  main 
faucet from the outlet of the stop valve. 

2.

 

Install  an  appropriate  T-adaptor  (preferably  with  3/8” 
BSP  male  thread,  for  connection  of  the  water  supply 
adaptor) at the outlet of the stop valve. 

3.

 

Reinstall the connection coming from the main faucet to 
one of the outlets of the T-adaptor. 

4.

 

Screw the water supply adaptor onto the other outlet of 
the  T-adaptor;  make  sure  the  gasket  is  installed  inside 
the female thread of the water supply adaptor. Tighten 
the water supply adaptor. 

 
WITH SEPARATE STOP VALVE (not included)  
 
1.

 

Install  an  appropriate  stop  valve  in  the  cold  water  line 
underneath  the  sink,  preferably  with  3/8”  BSP  male 
thread at the outlet. 

2.

 

Screw  the  water  supply  adaptor  onto  the  outlet  of  the 
stop  valve;  make  sure  the  gasket  is  installed  inside  the 
female thread of the water supply adaptor. Tighten the 
water supply adaptor. 

 

FILTER HOUSING UNIT 

 

 

Mount the filter housing unit in vertical position.  

 

 

Fix  the  filter  housing  unit  against  a  solid  surface  only 

(f.e.  wooden  wall  of  kitchen  cabinet),  using  suitable 
mounting screws (not included with this product!). 

 

 

Make  sure to leave  minimum  30  mm  clearance below 

the  filter  housing  unit,  to  allow  for  easy  removal  of  the 
filter sump during filter cartridge replacement. 

 

 

Make  sure  to  leave  minimum  75  mm  clearance  at 

either  side  of  the  filter  housing  unit,  to  allow  for  easy 
tubing connections. 

 

 

The  filter  housing  unit  has  an  integrated  mouting 

bracket at both sides, so it may be rotated 180° depending 
on  the  optimal  setup  of  the  inlet  (supply  of  untreated 
water) and outlet  (to  filtered  water  faucet) at  the specific 
place of installation. 

1.

 

Select  an  appropriate  location  under  the  sink  for  the 
installation of the filter housing unit. 

2.

 

Mark the location of the mounting screw(s) (1x for single 
sump models, 2x for double sump models).  

3.

 

Install the mounting screw(s). 

4.

 

Install the filter housing unit. 

5.

 

Tighten the mounting screw(s).  

 

FAUCET

 

 

 

Install  the  faucet  on  a  flat  surface  to  assure  secure 

installation  and adequate  sealing  between  the faucet and 
the counter top. 

 

 

Use  the  appropriate  tools  (drilling  machine,  drill  bit) 

and  procedures  to  make  the  hole  in  the  counter  top. 
Contact a professional if necessary, to avoid damage to the 
counter top. 

 

 

Make  sure  the  faucet  does  not  hinder  the  correct 

functioning of any other ‘device’ on top of the counter top 
(f.e. main faucet, window,…)     

 

 

Make sure to leave minimum 100 mm clearance under 

the counter top, to allow for easy installation of the faucet. 

 

 

Refer to the assembly diagram included with the faucet 

for correct assembly of the faucet. 
 
1.

 

Select an appropriate location for the installation of the 
faucet. 

2.

 

Drill a hole (with diameter of min. 12 mm – max. 15 mm) 
in the counter top. 

3.

 

Lower the faucet body through  the  hole in the counter 
top;  make  sure  the  o-ring  is  properly  installed  in  the 
faucets base. 

4.

 

From  underneath  the  counter  top,  install  the  washers 
and  locking  nut  over  the  threaded  stud  of  the  faucet 
body; tighten the locking nut. 

5.

 

Screw the faucet’s spout onto the faucets body. 

 

Содержание EFP10

Страница 1: ...2013 Aquion Inc OM EFP Rev2013 04 EN Installation Operating Instructions UNDER SINK DRINKING WATER FILTRATION SYSTEM EFP SERIES...

Страница 2: ...___________________________________ Phone number ______________________________________________ TRACKING FILTER CARTRIDGE REPLACEMENT Date __________________ Date ____________________ Date ___________...

Страница 3: ...s microbiologically unsafe or of unknown quality It will not purify heavily polluted water or make it safe to drink Installation of the water filtration system should only be undertaken by a competent...

Страница 4: ...ay time water pressure install a pressure reducer ahead of the water filtration system if necessary OPERATING TEMPERATURE min 2 max 45 C do not install the water filtration system in an environment wh...

Страница 5: ...ING UNIT Mount the filter housing unit in vertical position Fix the filter housing unit against a solid surface only f e wooden wall of kitchen cabinet using suitable mounting screws not included with...

Страница 6: ...rotective film is removed from the filter cartridge we recommend to install the filter cartridge in the water filtration system as soon as possible to avoid accidental damage or contamination of the f...

Страница 7: ...tely RINSING The water filtration system uses a filter cartridge containing activated carbon At first use some discoloration of the filtered water will occur This is totally harmless and will disappea...

Страница 8: ...o flow from the faucet close the faucet 3 Place a recipient underneath the filter sump to catch any spilled water 4 Unscrew the filter sump from the filter manifold by rotating the filter sump to the...

Страница 9: ...Page 9 EN English...

Страница 10: ...EN English Page 10...

Страница 11: ...Page 11 EN English...

Страница 12: ...AQUION INC Lammerdries Oost 30c B 2250 Olen Belgium 32 0 14 28 51 71 32 0 14 28 51 70 RPR RPM Turnhout BWT TVA VAT BE 0882 738 206 infobelgium eriewatertreatment com www eriewatertreatment com...

Отзывы: