7 - Preparation for operation and charging
1. Place the device on a dry flat surface.
2. Insert the USB-C plug of the power adapter and charger into
the socket. The battery must be fully charged before first use.
3. The LED starts flashing red.
4. Before the first operation, fill the glass container with max. 60o
C warm water and let it stand for at least 2 hours to moisten the
membrane cell completely. Finally, renew the water again and
shake for about one minute.
5. Then you can fill in the water that you want to enrich with
hydrogen and drink
. Only enough water should be poured in
so that the water level does not touch the pressure cap, so
that no water penetrates there.
6. At the end of the charging process, the LED lights up permanently green.
7. Remove the plug from the power supply and charging unit.
If
possible, the generator should not be operated during
charging due to battery wear.
8. If the LED starts flashing during operation, the power supply
and charger must be reconnected until the battery is charged.
9. If the power adapter is defective or not at hand, you can also
use a common USB-C power adapter, for example for
smartphones.
1
2
3-5 hrs.
ok
It is normal if there is some water/moisture in the
production tank when the unit is delivered, because the
membrane between the electrodes should always be
kept moist.