If the supplement should be dosed in a specific time of day or night, enter the time frame for the dosing to occur. If 
the supplement should be dosed in a specific day interval, enter the day interval desired for the dosing to occur. If 
the supplement should be dosed in on specific days of the week, enter the days of the week desired for the dosing 
to occur.

For Any Supplements:

Once a dosing schedule of any type is saved, returning to the schedule from the dashboard allows the user two 
more options for adjusting the dosing regimen; “Quick Adjust” and “Adaptive Dose”. “

Quick Adjust” simply allows for quick addition or subtraction to the dosing schedule by percentage. For example a 
dosing total can be reduced quickly and easily by 10% if required and conversly increased as necessary. Because it 
is prudent to adjust parameters slowly, the maximum adjustment in either direction is limited to +/-15% as a safety.

 “Adaptive Dose” offers an unparalleled means of fine tuning a dosing regimen over time. It is highly advisable to 
run a dosing schedule for a week at minimum for best results in using “Adaptive Dose”. Once a schedule is run 
with a supplement for at least a week, perform a test for the parameter for which the supplement is being dosed. 
For example, test calcium levels for a supplment that primarily doses calcium. Under “Adaptive Dose” enter the 
“Measured Level” from the test. Use the default already entered or enter your own “Desired Level” and touch the 
“Calculate” button.

The app will ask you to move through 3 important steps.

1.  If the “Measured Level” is below the “Desired Level”, a dose will be recommended over 48 hours to move 

the level up to the desired level safely. If the “Measured Level” is above the “Desired Level”, it will be 
recommended to suspend dosing over 48 hours to allow the level to drop toward the “Desired Level” safely

2.  A recommendation will be made for a new schedule based on the difference in the “Measured Level” and the 

“Desired Level” and the previous dosing schedule success/failure.

3.  A recommendation will be made to setup a testing reminder to provide results to input back into the 

“Adaptive Dose” in a week.

Each of these steps allows for opting out of “Adaptive Dose”.

Utilizing all 3 steps provides for the ultimate in continued refinement of a dosing regimen of any supplement to 
achieve the best results with a doser on an aquarium. As you repeat the “Adaptive Dose” the doser hones in on the 
best regimen for that specific supplement for your specific aquarium.

After entering a schedule of any type you are brought to the doser’s dashboard.

Содержание sentia dose

Страница 1: ...sentia dose User Manual Manual de instrucciones Manuel d instructions Manuale Istruzioni Manual de instru es Handleiding Bedienungsanleitung Instrukcja obs ugi Kullan m K lavuzu H ng d n s d ng...

Страница 2: ......

Страница 3: ...nting Bracket 4 Setting Up Doser Pump Heads and Tubing 4 The sentia App 5 Setting Up Aquariums in the App 5 Adding sentia Devices to the App 6 Device Setup 6 Notes on Dosing Schedules 9 The Dashboard...

Страница 4: ...e fuse or circuit breaker that supplies power to appliance Then unplug and examine for presence of water in the receptacle C Close supervision is necessary when any appliance is used by or near childr...

Страница 5: ...ne pas toucher les pi ces en mouvement ou chaudes comme chauffages r flecteurs ampoules etc D Toujours d brancher l appareil quand il n est pas utilis quand des pi ces doivent tre enlev es ou remplac...

Страница 6: ...ildren or mentally challenged individuals Appropriate adult supervision or persons responsible for personal safety is required 14 To prevent water from accidentally wetting the plug or electrical outl...

Страница 7: ...viding adequate electrical facilities EXCLUSION DAMAGES AND LIMITATION OF IMPLIED WARRANTIES Your sole and exclusive remedy is product repair or replacement as provided in this Limited Warranty The co...

Страница 8: ...fi A host of convenient and industry leading features make the sentia dose dosers the best choice in dosing systems for any aquarium A sentia dose Unit B Power Adaptor with Plugs Set North American EU...

Страница 9: ...A and slide the unit being connected to the right down onto the unit on the left Figure 1 B Replace all side covers to any exposed sides once connections are complete Primary Control Units and Seconda...

Страница 10: ...acilitate the best position for each user s application All sentia dose Primary Control Units and Secondary Units come with the Pump Head already assembled Connect a Tubing Connector to each end of th...

Страница 11: ...o specify the proper unit of volume being used Liters or US or Imperial Gallons This is critical to the proper function of the system and to avoid improper dosing It is essential to define not only th...

Страница 12: ...oosing Once the Ring Color is chosen the Ring Light on the doser itself will change to that color In the event that no color is desired choose black and the light on the doser will remain off Reservoi...

Страница 13: ...irections Adjustments can be made as necessary as time goes on Calculated Dose allows the entry of Measured Level from testing and compares it to the Desired Level to provide a dose that will bring th...

Страница 14: ...r the parameter for which the supplement is being dosed For example test calcium levels for a supplment that primarily doses calcium Under Adaptive Dose enter the Measured Level from the test Use the...

Страница 15: ...n Volume is displayed Pump Speed is displayed All programmed schedules are displayed as My Schedules Schedules can easily be added by touching the icon and saving the newly programmed schedule Any sch...

Страница 16: ...mory Configuration To reset the primary and secondary doser s to factory memory 1 Disconnect the power adapter 2 Press and hold down the right MODE and left dose water drop icon buttons simultaneously...

Отзывы: