May 2007
14
- The inlet of the
Adjust, see Figure 6.
Separator is not fully
inserted
into
the
socket
8.5 Stoppage in the
- The flushing water is
The pipe between WC and Separator has a too
fluid outlet of
entering the Separator large inclination. See Pipe Installation, Items 4.5.3,
the Separator
at too high speed
4.5.5 and 4.6.
8.6 Stoppage in the
- Sediments or foreign
Check that the fluid is not stopped in the UV unit or
fluid outlet of the
objects in the fluid
in the waterseal underneath it. Clean the UV unit and
system
outlet
the waterseal from sediments and foreign objects.
8.7 Flies in the
- Wet bio-bed
See Item 8.1 and 8.2 above.
Bio
Chamber
Spray the inside of the Bio Chamber with an
appropriate insecticide. Check the mosquitionet
at the top of the vent pipe.