Following the informational screens is the ability to change menu options. In 

order to change settings, bring up the option and press the right arrow until a small “p” 
appears in the lower right corner of the LCD. The user is then able to change the settings 
using the specified arrows for each setting.  
 
P

ASSWORD 

(enables password protection of settings) 

 

N

ONE

 – No password required to change settings 

S

ETUP

- Press the enter button and input up to an 8 digit (0-9) password, press the   

enter button to confirm new password. 

If the password is forgotten the user can perform a master reset by powering the 
unit on while holding the left and right arrows (this will reset all settings to the 
factory default settings). 
 

D

EFAULT

:

 None 

 
M

ANUAL 

O

VER

-

RIDE 

(turns on fill solenoid for specified time, for testing purposes) 

Manual Over-ride can be set from 5 seconds to 99 seconds. (use up and down 

arrows to change) To activate this option hold the left and right arrows for 
3 seconds.  

 

 

D

EFAULT

:

 10 seconds   

 
D

ELAY TO 

S

HUTOFF 

(time solenoid valve will stay on after sensor begins sensing water) 

 

Delay to Shutoff can be set from 2 seconds to 5 minutes. (use up and down arrows  

to change) 

 

 

D

EFAULT

:

 0:02 seconds 

 
M

AXIMUM 

O

T

IME 

(maximum time solenoid valve is allowed to stay on per fill cycle) 

Maximum On Time can be set from 30 minutes to 240 minutes using the up and  

down arrow buttons, or continuous using the left and right arrow buttons.  

 

 

D

EFAULT

:

 120 minutes 

 
A

LTERNATE 

S

ENSOR

 (enables alternate level feature option) 

 

On or Off (use left and right arrows to change) 

 

 

D

EFAULT

:

 Off 

 
D

ELAY TO 

N

ORMAL 

(time before solenoid is turned on after switching from alternate level  

sensing to normal level sensing) 
Delay to Normal can be set from 1 minute to 60 minutes. (use up and down  

arrows to change) 

 

 

D

EFAULT

:

 60:00 minutes 

 
H

IGH 

L

EVEL 

O

PTION

 (enables high level feature option) 

 

No or Yes (use left and right arrows to change) 

 

 

D

EFAULT

:

 No 

 
 
 

Содержание ELC-810 Series

Страница 1: ...810 AUTOMATIC WATER LEVEL CONTROLLER AquatiControl Technology 3820 South Federal Blvd Sheridan Colorado 80110 Toll Free 877 755 8817 Fax 303 761 1499 www aquaticontrol com Serial No __________________...

Страница 2: ...ACT 2009 2 TABLE OF CONTENTS Introduction 3 Installation 4 5 Wiring Diagram 6 Operation 7 9 Routine Maintenance 10 Troubleshooting 11 12 Warranty 13...

Страница 3: ...following pages of this manual The ELC 810 should ship with the following contents 1 Control unit Sensing Unit s Standard Well Sight Glass Wet Well Surge Tank Deck Well 1 Mounting Hardware 1 Operation...

Страница 4: ...l water level should sit approximately 1 5 up from the bottom of the end cap The surge tank sensing unit is installed in the surge tank at normal operating water level with the included clic connector...

Страница 5: ...In order to setup the use of an alternate level on the ELC 810 a second sensing application should be placed at the chosen lower water level and a flow switch supplied with the ELC 810 needs to be in...

Страница 6: ...ACT 2009 6...

Страница 7: ...arrows The enter button will bring you back to the startup screen Options can be changed by following the directions below The first six screens as you scroll down through the menu are for informatio...

Страница 8: ...seconds to 99 seconds use up and down arrows to change To activate this option hold the left and right arrows for 3 seconds DEFAULT 10 seconds DELAY TO SHUTOFF time solenoid valve will stay on after s...

Страница 9: ...ally closed flow switches Open or Closed use left and right arrows to change DEFAULT Closed SENSOR TYPE set to Other DEFAULT Other SOUNDER WITH ALARM beeping will occur when in alarm mode if yes is se...

Страница 10: ...RGE TANK The Surge Tank Sensing Unit will not normally need to be cleaned however if the cap on the bottom of the sensing application becomes clogged with debris it can be unscrewed and rinsed until c...

Страница 11: ...ective sensor Replace sensor Sensing unit not set properly Readjust sensor to water level Wiring is incorrect in sensor junction box Check wiring connection Level light does not come on Cable in ELC 8...

Страница 12: ...ACT 2009 12 SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Can t change settings Forgotten wrong password Reset ELC by turning the power on while holding the left and right arrows...

Страница 13: ...or part which is returned transportation prepaid to the factory within one year of delivery to the original purchaser and which is proven defective upon examination ACT disclaims all liability for da...