3
w w w . a q u a t i c l i f e . c o m
RO Daddy
™
Instruction Guide
MEMBRANE CONNECTION
The RO Daddy is shipped with a U – shaped connection that
needs to be installed.
This connection allows the pre-filtered water from the canisters
to flow into the membrane housing.
CONNECTING THE WASTE WATER LINE
AND FLUSH VALVE ASSEMBLY
➊
Locate the waste water connection on the right side
of the membrane housing. It should be labeled waste
and the elbow will be threaded directly into the
membrane housing.
➋
Connect the tubing into the elbow by removing the clip
located around the collar of the elbow. A small screwdriver
helps to remove the clip. When the clip is removed, insert
the tubing into the elbow.
You MUST make sure the tubing
is pressed into the fitting far enough to secure the tube.
You should feel a “Double Push” into the fitting this is a
result of the tube pushing past the seal in the connector.
➌
The flush valve assembly should now be connected to
the tubing that was just attached to the waste water side
of the membrane housing. The flush valve assembly
includes the flow restrictor and regulates the amount
of water that passes through the assembly. The flush valve
assembly also includes a bypass valve that allows water
to flow around the flow restrictor and flow faster through
the membrane. This “flushes” the membrane of buildup
and increases the life of the membrane. The membrane
should be flushed at least once a month or more if needed.
Filtered
Filtered
Waste
Waste