Aquatica Digital AQUATICA A40D Скачать руководство пользователя страница 11

Page10

CLOSING OF THE HOUSING

Before closing the housing always ensures that:

1. 

The main O-ring on the front half of the housing is clean, lubricated and properly seated for a 

 

positive seal.

2. 

The sealing surface on the rear half of the housing is clean and free from any scratches or physical 

 

damage.

3. 

All cords or wires are tucked in so that they do not interfere with the closing of the housing.

4. 

The Function dials Knob on the rear half of housing is pulled out to allow clearance when closing 

 

the housing.

To close the housing simply:

I. 

Join the front and rear halves of the housing using the two dowel pins at the bottom of the housing 

 

as a guide. 

ii. 

Hold the housing with both hands and look around the sealing surface to ensure that the O-ring 

 

remained properly seated and that no cords, wires or “D-rings” are caught between the edges.

iii. 

Close the two latches simultaneously. CAUTION: if you feel any resistance as you attempt to close 

 

the latches, do not force the closure. Check for an obstruction and try again. 

iv. 

Verify that the safety locking mechanisms of the latches are properly engaged to avoid any accidental 

 

opening.

LENS INSTALLATION

 

With the camera inside the housing, install the lens prepared with the gears through the port opening in the 

front of the housing. Ensure that the lens mounted gears are properly installed and aligned. Rotate the focus 

control knobs to ensure that the gears are properly meshed, do not grind and that their rotation is smooth.

Note: to avoid breaking the auto-focus mechanism of the camera you should set the Focus Control to “M” 

Manual before testing the proper meshing of the gears.

CHANGING A LENS (REMOVING A LENS)

The lens mounted gears may restrict the view and ease of access to the lens release button of camera. A stick 

or a pencil can be used to push the lens release button on the camera body

MOUNTING AND DISMOUNTING THE PORT

Before mounting the Port on the Housing always ensures that the locking mecanism inside is in the open posi-

tion before mounting a port and that the port O-ring is clean, lubricated and properly seated in its groove as 

well as making sure that the sealing surface on the Housing is clean and free of physical damage.

Содержание AQUATICA A40D

Страница 1: ...INSTRUCTION FOR AQUATICA A40D Housing for the Canon 40D...

Страница 2: ...long and continuing relationship with the most demand ing underwater photographers in the world Each housings is handcrafted quality checked and pressure tested to 300 feet by a small group of special...

Страница 3: ...n flooding or poor functioning of the controls Be careful when opening the housing as the pressure build up inside the housing will exaggerate the force of the latch spring Keep fingers away from the...

Страница 4: ...14 GRIPS X2 15 MOUNTING HOLES 1 4 X 20 16 BAYONNET MOUNTING FLANGE 17 LATCHES X2 18 TOP LCD DISPLAY WINDOW 19 AF POINT SELECTOR ENLARGE BUTTON 20 STAR AE FE LOCK INDEX REDUCE LEVER 21 QUICK CONTROL KN...

Страница 5: ...Mode Dial D Focus and or Zoom E AE FE control D AF point selection E LCD illumination F Exposure Compensation or Aperture Value G ISO H White balance I Menu J Jump function K Playback function L Eras...

Страница 6: ...Rotate counter clockwise to disengage lens from the camera body Make sure port is removed before attempting to change lenses on the camera 12 CAMERA MOUNTING SADDLE Allows quick and easy removal of ca...

Страница 7: ...icture style function and menu 29 INFO BUTTON allow viewing of image s shooting information 30 JUMP BUTTON press to allow the navigation between images 31 ERASE BUTTON Press to engage the image delete...

Страница 8: ...g on whether you ve decided to shoot macro or wide angle photography you will be installing either a flat Macro Port product 18426 for MF AF or 18428 for AF only 9 25 Megadome 18407 8 Dome Port Produc...

Страница 9: ...distance 2 Mount the focus gear over the focus ring of the lens such that the round indentation etched on the side of the gear is facing the rear of lens and is aligned with the Distance Index of the...

Страница 10: ...a before closing the housing 4 Carefully place the camera on the saddle and ensure the camera is properly installed and aligned as follows A The camera is properly aligned and secured against rotation...

Страница 11: ...ction and try again iv Verify that the safety locking mechanisms of the latches are properly engaged to avoid any accidental opening LENS INSTALLATION With the camera inside the housing install the le...

Страница 12: ...ica tions For example Aquatica TLC makes a strobe arm mounting tray that will fit on the bottom of the housing Two 1 4 20 threaded holes on top of the housing will accept an Aquatica bracket or Base B...

Страница 13: ...opes of other equipment stay clear of the system When photographing be sure to respect the environment Avoid damaging marine life or manipulating sea creatures to obtain a pleasing photo The housing i...

Страница 14: ...will not seriously impair image quality Internal scratches air side must be avoided as they do not fill in with water and will affect the quality of the image Clean the dome using only products recom...

Страница 15: ...O ring place the entire O ring over the groove and start by pushing the O ring in at each corner then push the O ring at each side and finally work in the rest of the O ring Never start at one end an...

Страница 16: ...7 18482 18708 17 40mm f 4L EF 18405 18457 18482 18709 17 85mm f 4 5 6 EF S 18405 18453 18482 18707 18 55mm f 3 5 5 6 EF S 18405 18482 18703 PORT DOME FOCUS ZOOM OTHER BRAND LENSES PORTS EXTENSION SHAD...

Страница 17: ...FOR AQUA VIEW FINDER 18480 DOME SHADE F E 18480 DOME SHADE W A ZOOM FOCUS GEARS MAINTENANCE REBUILT O RING KITS EXTENSION RINGS Please visit our website at www aquatica ca for a complete selection of...

Отзывы: