background image

Page 12

For Aquatica housing with  the optional Ikelite integrated conversion circuitry 

The A7D Mk II model # 20077-KT is a housing is equipped with an Ikelite designed and patented TTL conversion 

circuitry. Once attached to the housing, you should turn the strobe on first before turning the power on the camera. 

When used with current Ikelite DS Strobes, the TTL Conversion Circuitry provides real flash exposure with over and underexposure 

compensation from +1 1/3 to - 1 1/3 f-stops in 1/3 stop increments. The Conversion Circuitry also offers Manual exposure control with 

3 f-stops of under exposure control in 1/2 stop increments. The Conversion Circuitry is powered by the Ikelite DS Strobe when connected 

to the housing with the 4103.51 single or 4103.52 dual sync cord. When using two strobes with the dual sync cord, the primary strobe 

connected to the cord without the red band, must be turned on to power the Conversion Circuitry. Always keep both strobes connected 

to your dual sync cord underwater. 

Setting the Conversion Circuitry Strobe ID Switch

Inside the back cover of the A7D Mk II housing is a switch for setting the DS Strobe ID. 

Set the switch to the Model of DS Strobe being used. 

Use 

(A) for DS-51

 or 

(B) for DS 161,160, 125 & 200.

 Whenever using two Ikelite 

strobes of different models such as a DS51 and a DS161, set the ID switch to (A) 

DS51 or the smaller strobe.

Using the Conversion Circuitry (Set DS Strobe to TTL mode) 

Mode and Compensation Dial (see illustration)

 

Note that the TTL compensation values are located in the yellow band. Manual compensation 

values are located in the black band. Rotate the Dial to switch between TTL and Manual Modes. 

TTL Mode

 compensation values are indicated in the yellow band. Place the Setting 

Indicator  to  TTL  for  NO  Compensation.  Rotate  the  dial  either  direction  to  select 

+/- compensation. Place the Setting Indicator to the desired compensation value. Note 

that in TTL, compensation values are in 1/3 f-stops. 

Manual Mode

 compensation values are indicated in the black band. Rotate the Dial to 

place the 

setting indicator to the desired compensation value. Note that in manual mode, compensation values 

are in 1/2 f-stops from (F) full power to -3 f-stops. Set DS Strobe to TTL mode. This will allow the strobe power to be varied in manual mode. 

Attaching the Flash Connection for external strobes

When using an external strobe, connect the housing hotshoe connector. Slide the connector 

into the hotshoe mount on the camera from the back of the camera as shown. Slide the 

connector forward until it stops. Make sure the hotshoe is all the way forward in the camera 

mount to assure a good connection. 

Using Non-Ikelite or Ikelite Non-DS Strobes (Strobe 50, 100A, 200, 400) with this Housing 

The Conversion Circuitry is automatically disabled when used with a Non-Ikelite or Non-DS 

Strobe. These Strobes can be used in their manual mode utilizing any power settings 

provided on the Strobe.

For  a  complete  list  of  compatible  models  of  strobes,  please  check  with  Ikelite 

(www.ikelite.com) to confirm that your strobe is compatible with this TTL circuitry

Содержание A7D Mk II

Страница 1: ...OPERATING MANUAL FOR AQUATICA A7D Mk II PRODUCT 20077...

Страница 2: ......

Страница 3: ...Preparation and installation of the lens Page 9 Selecting focusing mode Page 10 Mounting a port and or extension on the housing Page 10 Connecting lighting equipments to the housing Page 11 Using wir...

Страница 4: ...easy to operate controls for most of the manual and computerized camera functions including the following controls Extended Mechanical Shutter Release Lever Large knurled knob for accessing Shutter s...

Страница 5: ...ports and windows Always confirm that the ports remain properly attached before rinsing the housing An optional port locking collars is available 18469 for securing larger dome to the extension ring W...

Страница 6: ...Page 3...

Страница 7: ...Page 4...

Страница 8: ...Turning allows manual focus of a single focus lens or rotation of the zoom mechanism of a lens 17 Focus Zoom control release disc Lifting and rotating this disc to its resting post will retract the pi...

Страница 9: ...ivate the Quick Control feature navigate using the Multi Controller or using the Main dial or and Quick Control access knobs 48 SET button Press to approve selection of menu or chosen mode features 49...

Страница 10: ...aluminum rings ex tend the internal space of a Flat Macro Port some shorter macro lens do not require using one but longer lenses 100mm and longer will need one in order to provide the necessary space...

Страница 11: ...r flap of the microphone plug cover safely out of the way 4 Slide the quick release tray 1 back into place it will lock itself into place 5 If using hot shoe triggerred strobes insert the hot shoe as...

Страница 12: ...Zoom Focus Release Disc key 17 clear open the housing back cover remove the hot shoe from the camera and pull out the complete camera lens from the housing replace the lens and reinstall in the revers...

Страница 13: ...k on a soft and steady surface 2 Place the port or extension ring inside the bayonet of the housing Align one of the four alignment notches with the opening of the housing 3 Place your hands on opposi...

Страница 14: ...nected directly to the camera in eTTL mode exposure will stop to function and a camera freeze is likely to happen Two underwater strobes can only be connected electrically if a TTL converter is interf...

Страница 15: ...d Compensation Dial see illustration Note that the TTL compensation values are located in the yellow band Manual compensation values are located in the black band Rotate the Dial to switch between TTL...

Страница 16: ...d MAINTENANCE OF HOUSING AND PORTS When changing ports or O rings a simple seal test without the camera inside should be performed Strapping a weight to the housing and lowering the unit to a depth of...

Страница 17: ...quality Internal scratches air side must be avoided as they do not fill in with water and will affect the quality of the image Clean dome lenses only with soft lint free tissue Dust on the interior su...

Страница 18: ...ver INCLUDED 18410 4 Mini Dome 100 CANADA Made in Aqua View Finder 20054 Protective Hard Case 19216 Moisture Vacuum sensor 3Volts Hydrophone 19221 0 Aqua View 45 Finder 20059 450 Replacement Viewfinde...

Страница 19: ...ANY OTHER REASON IS NOT THE RESPONSABILLITY OF AQUATICA Therefore the appropriate insurance should be maintained by the user Warranty does not apply to replaceable seals or damages to impacts or abras...

Отзывы: