Of the Latches:

The two latches of the AQUATICA Digital are equipped with safety locking tabs, their locking action prevent 

accidental opening of the latches. To open push the safety locking tab (A) and then lift the two latches (B) si

-

multaneously as per illustration. When closing and prior to the immersing the housing always ensure that the 

locking tab mechanism is engaged. Watch for the build-up of corrosion or salt residue around the latches. This 

will appear as a white material. Lubricate the latches with a small amount of WD-40 to remove the corrosion or 

salt residue build-up.

Of the O-Rings:

The O-rings that need to be maintained on a regular basis are the main housing O-ring and the O-ring on the 

lens port The main O-ring should be cleaned and inspected on a daily basis and the port O-ring should be 

cleaned every time a port or extension is changed or removed.

Of the sacrificial anode:

Two anodes (# 50) are attached to the bottom part of the housing. These prevent corrosion caused by electrolysis, as time goes they will deteriorates and 

eventually will require replacing, contact your dealer for replacement (parts # 19220).

TO SERVICE O-RINGS ON THE HOUSING MAIN O-RING, PORTS AND EXTENSION RINGS

1. 

Remove the O-ring. It is important never to use a sharp instrument when removing an O-ring as this 

 

may damage the O-ring groove or the O-ring itself. A dull pointed object or the edge of a credit card 

 

usually works well.

Note: 

The main O-ring is inserted in an inverted V groove to prevent it from popping out accidentally, to remove, 

use a dull pointed object and insert in the side of the small opening on the lower left hand side corner of the 

front of the housing. Do not use sharp objects or excessive force; this could result in damage to the sealing 

surface.

2.  

Once the O-ring is removed, it should be examined for damage. Check to make sure that the O-ring 

 

is free of nicks and cuts and that it retains its original round profile. O-rings that appear to be damaged 

 

should be discarded immediately and replaced with new O-rings.

3.  

Rinse the O-ring with fresh water and dry it with a clean lint free cloth.

4.  

Clean the O-ring groove (where the O-ring sits) with a cotton swab. Be sure to remove any lint the 

 

cotton swab may leave behind. Inspect the groove for damage.

5.  

Wipe the part of the housing that the O-ring seals against with a clean lint-free cloth.

6.  

Re-grease the O-ring with a thin layer of O-ring grease until it appears to be smooth and shiny. Do not over grease it. Use just enough grease so 

 

the O-ring will pull smoothly through your fingers. Excessive amounts of grease will only serve to attract dirt to the o-ring.

7.  

Make sure that the O-ring is properly (evenly) installed in the O-ring groove.

8.  

To reinstall the clean and lubricated O-ring, place the entire O-ring over the groove and start by pushing the O-ring in at each corner then, push 

 

the O-ring at each side and finally, work in the rest of the O-ring. Never start at one end and work your way around the O-ring. This places uneven 

 

tension on the O-ring which may cause the O-ring to stretch resulting in excess O-ring, which will have no place to go.

Warning: Use only recommended Aquatica O-ring lubricant (# 19213) on the Aquatica Housing (and use the recommended O-ring lubricant of your strobe 

manufacturer on their components O-rings), Petroleum based lubricant used by some manufacturers for their Silicone based O-rings can and will swell 

the material of our O-rings, this will render the O-ring very difficult to install and more likely will end up being damaged or pinched resulting in dire conse

-

quences

Internal O-rings on the housing controls are not user accessible, while these O-rings are not as susceptible to damage as they are not exposed, rinsing 

properly with fresh water to flush out salt crystals and sand residues will be the proper way to assure trouble free operation. It is recommended by Aquatica 

to have the housing serviced on a yearly basis. Aquatica has authorized service facility in both con

-

tinental USA and Europe for this annual maintenance. Before sending any items, always contact us 

or the service center closest to you (these are listed on our website www.aquatica.ca).

The internal moisture alarm for your AQUATICA Digital housing (Product # 20023) is powered by 

an easily available CR 2032 battery. Please read the instruction sheet provided for your moisture 

alarm prior for installation and operation. 

 

When installing the moisture alarm battery, to avoid crushing the positive battery contact as shown 

in image below, first insert it as per (A) then just press it in to place (B)

To avoid unnecessary power drainage, it is recommended that the battery be removed from the 

moisture alarm when storing or not using the housing for extended period of time

ENTRY POINT

INVERTED “V” GROOVE

Содержание A5D mkIII

Страница 1: ......

Страница 2: ......

Страница 3: ...or malfunction Please read and follow the following precautions Store and transport the housing in a sturdy shock proof container and avoid travelling with the camera mounted inside the housing as impact forces especially on the external push buttons will be transferred to the camera When travelling by air either remove the port or open the housing Never change a port or open the housing in a loca...

Страница 4: ...19 20 21 22 23 27 24 25 25 26 28 29 30 31 32 17 33 34 35 36 37 40 38 40 41 42 43 44 44 45 39 19 20 1 3 46 4 47 5 6 8 9 48 49 18 49 50 50 20 19 41 1 2 11 9 52 25 14 51 52 Thumb operated Index operated 53 19224 Optional ISO Extended Lever Page 2 Nomenclature ...

Страница 5: ...g Movie Shooting Switch 24 Power Switch 25 Mode Dial selector knob 26 Mode Dial port window 27 Mode Dial lock release lever 28 Info button 29 Menu button 30 Creative Photo button 31 Rate button 32 Index Magnify button 33 Playback button 34 Erase button 35 LCD Window port 36 Removable Eye Piece 37 Quick Control Button 38 Multi Controller Buttons Array 39 Setting Button 40 Latches 2x 41 Quick Contro...

Страница 6: ...ows manual focus of a prime lens or rotation of the zoom mechanism on a zoom lens 10 FOCUS ZOOM PINION GEAR Engages and operates the focus or zoom gear attached to the lens 11 LENS RELEASE LEVER Activates the lens release button on the camera for removal of the lens 12 LENS RELEASE LEVER ACTUATOR Applies pressure on the camera lens lock button 13 GRIPS X2 Left and right grip allowing the mounting ...

Страница 7: ...t in RAW format and concentrate on these option in post production 31 RATE BUTTON Press to select the desired rating you wish to allocate to the image 32 INDEX MAGNIFY BUTTON Press to access the index and to magnify the reviewed image 33 PLAYBACK BUTTON Press to activate the monitor and review images 34 ERASE BUTTON Press to delete images 35 REAR WINDOW LCD This port window allows viewing of the r...

Страница 8: ... Extended Lever accessory product 19224 See item 53 below for more information 47 AF DRIVE SELECTOR BUTTON press to select either AF Mode or the DRIVE modes options 48 METERING PATTERN WHITE BALANCE MODE BUTTON Press to select the appropriate metering mode and or White Balance mode 49 RUBBER ANTI SKID PADS Four rubber pads are provided to protect the housing and preventing it from sliding on wet d...

Страница 9: ...right and left 13 these attaches on the sides of the housing with the supplied cap screws and Hexagonal wrench we strongly recommend to occasionally remove the grips and lubricate the screws see Care and Maintenance of the housing You can mount the necessary shoes or brackets for your strobe system onto the 1 4 20 threaded holes provided on top of the hand grips The AQUATICA TLC strobe arm system ...

Страница 10: ...ed Care and Maintenance of the O rings PREPARATION OF THE LENS Aquatica has a wide selection of Focus and Zoom gears to accommodate the most popular lenses used in underwater photography Correctly mounting and securing these gears on a lens is elementary for a smooth operation Follow the installation directions included with each gears carefully The use of EF type s lenses is mandatory A comprehen...

Страница 11: ...tween the rear and front of the housing this is a critical and essential thing to check CLOSING OF THE HOUSING Before closing the housing always verifies that 1 The main O ring on the front half of the housing is clean lubricated and properly seated for a positive seal 2 The sealing surface on the rear half of the housing is clean and free from any scratches or physical damage 3 All cords or wires...

Страница 12: ...vely pulling on the retracting disc 8 underneath the Focus Zoom knob 9 and turning it so that it stay in the up position will disengage the pinion gear 10 from the focus or zoom gear attached to the lens pull out the lens release 11 and you can then pull the camera right out of the housing with the lens and gear attached MOUNTING THE PORT Before mounting the Port on the Housing always ensures that...

Страница 13: ... the two following methods 1 By using a single flash from Canon or other brand eTTL compatible brand in a designated underwater housing con nected with a 6 pins TTL sync cord to a compatible 6 pins connectors on your Aquatica housing 2 By using an external eTTL converter connected to the main Nikonos type 6 pins connector on your Aquatica housing On this converter one or two underwater strobes wit...

Страница 14: ...UATICA Pro Digital housing in a sturdy shock proof container When travelling by air remove or loosen the port This al lows for equalization of the air pressure inside the housing to the external air pressure Failure to do so may cause serious damage to the acrylic ports Avoid travelling with the camera mounted in the housing If you must do so remove the lens as external pressure can damage the cam...

Страница 15: ...of the housing that the O ring seals against with a clean lint free cloth 6 Re grease the O ring with a thin layer of O ring grease until it appears to be smooth and shiny Do not over grease it Use just enough grease so the O ring will pull smoothly through your fingers Excessive amounts of grease will only serve to attract dirt to the o ring 7 Make sure that the O ring is properly evenly installe...

Страница 16: ...g Kit Maintenance O ring Kit 18843 18843 Standard Viewfinder 19218 INCLUDED 18789 HOUSING PROTECTIVE CAP Sacrificial Anodes 4 x anodes and screws 19220 Surveyor moisture and vacuum sensor 19229 A5DMkIII A5D Mk III For Canon 5D Mk III Bulkhead connections 20071 Double Nikonos connectors 20071 KM One Ikelite 2 pins connector to know more about connectors refer to our website at www aquatica ca Hydro...

Страница 17: ... 6 Dome Shade 18430 Mini Macro Port 19352 5 Close Up lens 19353 10 Close Up lens 19357 77mm to 67mm Step Down Ring 48462 48456 48456 48463 48457 48455 48453 48465 48458 48459 48466 48454 48468 48467 48464 18790 Rear port protective cap Focus gear required with these ports Focus gear required with these ports W A R N IN G This cov er is for tran spor t prot ecti on only and is not wate rpro of DO N...

Страница 18: ...ER REASON IS NOT THE RESPONSABILLITY OF AQUATICA Therefore the appropriate insurance should be maintained by the user Warranty does not apply to replaceable seals or damages to impacts or abrasive surfaces Warranty applies only to products purchased from authorized AQUATICA dealers and does not extend beyond the original retail purchaser Unauthorized modifications or repairs will automatically voi...

Страница 19: ...___________________________________________________________________________________ __________________________________________________________________________________________ _________________________________________________________________________________________ __________________________________________________________________________________________ ____________________________________________...

Отзывы: