CARE AND MAINTENANCE

 INITIAL CLEANING

Before tub is used, the whirlpool system should be cleaned and disinfected. Remove all debris and clean tub before  

putting whirlpool into service. DO NOT USE ABRASIVE CLEANERS ON THE ACRYLIC FINISH. Use a non-abrasive  

detergent and rinse well after cleaning. 

•   Fill the tub with HOT water to a level 2” above the highest jet.
•   Add 2 teaspoons of low-sudsing automatic dishwashing detergent and no more than 4 ounces of household 

bleach to the water.

•   Operate whirlpool for 10 minutes. Drain. 

Note:

 To effectively clean both the whirlpool and air bath system, you 

must operate them both. 

•   Refill with cold water and operate whirlpool for 5 minutes. Drain.

 WHIRLPOOL SYSTEM CLEANING

To remove accumulations of bath residue from the whirlpool system, we recommend that you purge it at least twice a 

month, or more depending on usage. To do this, follow this simple procedure. Fill the bath with hot water (not exceeding 

140

o

 F). Add to the hot water, 4 (6) tablespoons of low foaming detergent such as liquid Cascade or Calgonite and 24 

(48) oz. of liquid household bleach, such as Clorox [use lesser amounts shown for 5-foot bathtubs, greater amounts in pa-

rentheses for larger bathtubs]. Run the bath for 5 to 10 minutes. Drain the bath completely and refill with cold water only. 

Run the whirlpool for 5 to 10 minutes, then drain the bath completely. Depending on the usage and/or the content of the 

local water supply, more frequent purging may be necessary.

 AIR BATH SYSTEM CLEANING

NOTE: DO NOT TURN THE PUMP ON DURING THE AIR BATH CLEANING.

Before tub is used, your air bath and plumbing system should be flushed. Close the drain. Fill bath with hot water to at 

least six inches above air injector holes. Add 2 teaspoons of low sudsing automatic dishwashing detergent and no more 

than 4 ounces of bleach to the water. 

DO NOT

 use bleach or other chlorinated cleansers on metal trim surrounding  

control panels. Turn blower on for approximately two minutes to mix cleaner with water. Shut blower down and allow 

cleaner to soak in the bath for approximately two hours. Turn ON air bath and run for approximately five minutes. Turn  

air bath unit OFF and drain tub. Aquatic recommends the above cleaning process on your air bath system once a month.

NOTE: DO NOT USE OIL OR OIL BASED BATH ADDITIVES.

If you want to use any kind of bath additive, use only a small amount of low-foaming powder or crystal substance; the 

whirlpool action intensifies the foaming properties of soaps. The use of certain bubble baths and bath additives may 

increase the level of accumulations of bath residue in the whirlpool system. If excess accumulations persist, you should 

discontinue use of these products.

If you have followed the monthly purging instructions and still have an excess accumulation of bath residue and desire 

an alternative cleaning mechanism, we recommend 

SUPER SYSTEMS CLEAN PLUS

 manufactured by Stearns Packaging 

Corporation to rectify this condition. This may be obtained by calling Aquatic, at (800) 945-2726. It is recommended 

that you follow the instructions provided by the manufacturer with the product. Repeated use may be necessary. 

SUPER 

SYSTEMS CLEAN PLUS

 does not replace the necessity to purge your whirlpool system at least twice a month with a low 

foaming detergent and bleach.

 SURFACE CLEANING

Use common household, non-abrasive cleaners for most cleaning jobs. Rinse well and dry with a clean cloth. Never use 

abrasive cleaners. Do not allow your Lucite® acrylic surface to come into contact with products such as acetone (nail pol-

ish remover), nail polish, dry cleaning solution, lacquer thinners, gasoline, pine oil, etc. Remove dust with a soft, dry cloth. 

Clean grease, oil, paint, and ink stains with isopropyl (rubbing) alcohol.

Содержание LuxeAir Series

Страница 1: ...R S MANUAL INSTALLATION GUIDE LUXEAIR SERIES Note Read all instructions before proceeding with installation All specifications are 1 4 and are subject to change without notice Dimensions listed in inches mm ...

Страница 2: ...ctrical Installation 11 12 Component Breakdown 13 14 OPERATION Jet Operations 15 Inline Maintenance Heater Operating Instructions 16 Bathside Control Systems 17 19 To Replace LED Light 20 CARE AND MAINTENANCE Initial Cleaning 21 Whirlpool System Cleaning 21 Air Bath System Cleaning 21 Surface Cleaning 21 Jet Cleaning 22 Surface Scratch Removal 22 Repair 22 Water Quality Issues 22 24 User Informati...

Страница 3: ...nd reference when contacting the distributor to expedite warranty claims OWNER INFORMATION Model Name Serial Number Purchase Date Distributor AQUATIC Product Registration Information 8101 E Kaiser Blvd Anaheim CA 92808 800 945 2726 Fax 866 544 5353 www aquaticbath com Model Serial Number Location The tub model and serial numbers are located above the pump area on the backside of the bathtub An acc...

Страница 4: ...ructions during the life of your whirlpool Failure to comply with these instructions may invalidate your warranty If you have any questions concerning installation operation maintenance or any other aspect of your whirlpool please contact AQUATIC CUSTOMER SERVICE CENTER 800 945 2726 The Troubleshooting Guide on page 26 may be helpful in answering some of your questions CONGRATULATIONS IMPORTANT Th...

Страница 5: ...may lead to unconsciousness with the possibility of drowning Never use the whirlpool while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers G Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a whirlpool H...

Страница 6: ... leaks 5 Plug in pump and blower cords and run pump for 10 minutes 6 With the pump running turn on the blower Check all functions 7 Inspect the tub completely Any defect must be reported to Aquatic prior to installation in order to have it covered by warranty Should inspection indicate any damage do not install the bath 8 Check to ensure that your installation will conform to all applicable codes ...

Страница 7: ...This will help in leveling the tub on uneven floors and will help in reducing vibrations and noise 3 Tub must rest entirely on all leveling feet or ABS Support Base DO NOT SUPPORT THE WEIGHT OF THE TUB BY THE RIM Lift unit and place into framework Secure the unit by fastening the bottom feet to the sub floor with any construction adhesive caulk For quieter operation and heat conservation the walls...

Страница 8: ...e bath C Install water resistant drywall against the tile flange and flush to the top of the whirlpool deck Install the tile or other finishing materials Apply a second bead of silicone between the first course of tile and the bath deck NOTE Before tub is used the whirlpool system should be cleaned in accordance with the procedures on Page 21 of this manual LUXEAIR 31 32 INTEGRALLY SKIRTED BATHS A...

Страница 9: ...sts firmly on ledger strip see Figure 3A 5 See and follow Sealing Finishing Figure 3B REMOVABLE SKIRT PANELS FOR INTEGRALLY SKIRTED MODELS These models are offered with removable panels It provides a flush to wall installation sheet rock overlaps skirt while still providing access The skirt features a decorative removable panel enabling easy access to motor pump blower and electrical hookups Clips...

Страница 10: ...ons on each tub and specifications are subject to change as we improve upon our product as required The dimensions needed for site preparation and structure building will differ Aquatic assumes no responsibility for preparatory work B A Figure 5 PLUMBING 1 After securing tub in place normal waste and overflow and valves are installed per normal plumbing procedures in accordance with all state and ...

Страница 11: ...in the main circuit breaker panel Connect the black wire to the hot side of the receptacle the white wire to the neutral side of the receptacle and the green wire to ground Replace the cover and plug in the blower See Figure on page 12 The second junction box will have two outlets one labeled Main and the other labeled Heater Remove the cover Run Romex 14 3 with ground from a 15 amp 2 pole GFCI br...

Страница 12: ...ater and then to the cold water plumbing or other suitable ground Grounding is required Grounding is NOT required for the blower INSTALLATION INSTRUCTIONS ELECTRICAL INSTALLATION CONTINUED TEST RESET Heater Pump Blower White Neutral White Neutral Ground Black Load Black Load Red Load Ground 15amp 1 pole GFCI Breaker on off 15amp 2 pole GFCI Breaker ...

Страница 13: ...lation Guide Figure 7 GECKO INPUT OUTPUT GECKO INPUT OUTPUT TEST RESET HEAT MASTER 1 5kw Heater TEST RESET LuxeAir Series component breakdown No Chromatherapy TEST RESET Pump Controller Blower Controller Blower Pump Topside Controller Water Sensors ...

Страница 14: ...gure 8 GECKO INPUT OUTPUT GECKO INPUT OUTPUT TEST RESET HEAT MASTER 1 5kw Heater TEST RESET LuxeAir Series component breakdown With Chromatherapy TEST RESET Pump Controller Blower Controller Blower Pump Topside Controller Water Sensors On Off Pump Button LED Light ...

Страница 15: ...Full Size Pressure Flo Hydrotherapy jet is fully adjustable for direction of water flow and intensity of pressure StressEaz Neck and Shoulder Massage Jet Aquatic StressEaz Jets feature two side by side oval ports through which water moves simultaneously in opposite directions to create a constant circular motion This unique design effectively creates a consistent even massage for the user s neck a...

Страница 16: ...TOR LIGHT The light turns on when the heater is operating PRESSURE VACUUM SWITCH The heater is equipped with a preset pressure or vacuum switch The pump must be run ning with water flowing to the whirlpool to allow the heater to turn on WARNING Prolonged Immersions in Hotter Water May Induce Hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees ...

Страница 17: ... blower down using the minus button to a lower setting to reduce the amount of water being dispersed from the tub Air Bath Purge Cycle Twenty minutes after the pump or blower is turned off either manually or by the timer the blower will turn on at full power for 3 minutes to purge the air channels of water During this 20 minute waiting period depressing the on off button will cancel the purge cycl...

Страница 18: ... To Turn Chromatherapy Light On Press the light button once to turn the Chromatherapy Light on in color wash mode A second press of the button will turn the lighting system off Subsequent presses will move the lighting system through the seven constant color modes CAUTION Due to the varied size weight and shape of a person s body water may splash out of the tub when the air blower is on high speed...

Страница 19: ...rate A different blinking rate was picked in order to make it easier for the user to differentiate it from the standby of the regular purge cycle The purge will be done every day at the same time the user activated it pressed the button By pressing the button again the 24 hour purge will be deactivated and the light indicator on the on off button will stop blinking and turn off On Off Control for ...

Страница 20: ... not attempt to remove the lens without the provided tool 4 Replace your LED light replacement LED lights can be obtained from Aquatic 5 Verify O ring is not damaged and is properly positioned in the groove when replacing the lens If there is damage or lens does not seal properly do not refill bathtub NOTE Do not twist LED light into socket Use gentle pressure and push LED light into place Lens In...

Страница 21: ...ow sudsing automatic dishwashing detergent and no more than 4 ounces of bleach to the water DO NOT use bleach or other chlorinated cleansers on metal trim surrounding control panels Turn blower on for approximately two minutes to mix cleaner with water Shut blower down and allow cleaner to soak in the bath for approximately two hours Turn ON air bath and run for approximately five minutes Turn air...

Страница 22: ...read and observe all instructions and or warnings on containers containing substances you contemplate applying to your whirlpool Any failure to comply may void your warranty WATER QUALITY ISSUES Owners of fill and drain whirlpool bathtubs need to know basic information concerning water quality how it affects performance and enjoyment of the operation of their tubs and steps that can be taken by th...

Страница 23: ...leaning action of soaps and detergents causing expense in the form of extra work and cleaning agents When hard water is heated it will deposit a hard scale With regard to whirlpool bathtubs high calcium and or magnesium levels may result in the formation of white stains and scale formation on the in side of the tubs especially noticeable with colored tubs If this occurs you need to contact the wat...

Страница 24: ...aning may be necessary if these products are used in the whirlpool tub If excess accumulations persist you should discontinue use of these products If you have followed the monthly purging instructions and still have an excess accumulation of bath residue and desire an alternative cleaning mechanism we recommend SUPER SYSTEMS CLEAN PLUS manufactured by Stearns Packaging Corporation to rectify this...

Страница 25: ...FCC rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference which can be determined by turning the equipment on and off the user is encouraged to try to correct the interference by one or more of the followin...

Страница 26: ...ic 2 Refer to installer dealer 3 Clean and unplug 4 Contact Aquatic If you have a remote pump refer to installer dealer Leakage of water at shaft 1 Shaft seal requires replacement 1 Contact Aquatic Leaking unions 1 O ring missing or damaged 2 Plumbing in a bind 3 Loose unions 1 Contact Aquatic 2 Contact Aquatic 3 Tighten unions Vibration noise 1 Tub or tub plumbing is touching tile wall 2 Pump is ...

Страница 27: ...ic for parts pricing and shipping charges IMPORTANT The following information MUST accompany your order Serial Number Model Number Name Purchase Date and Color BILL TO Name Company Address City State Zip Phone Fax PLEASE FILL OUT COMPLETELY Serial ________________________________ Model Name__________________________________ Model _____________________ Color___________________ Purchase Date _______...

Страница 28: ...matherapy option 3c 3a 1104PAD Pump Blower Control NO Chromatherapy option 3b 100667 Pump control WITH Chromatherapy option 3c 1110PADCL Airbath control WITH Chromatherapy option 2b 2a 2c 1a 8186ASSYxx Full size directional jet 1b 8186VJTB V jet body 8186BDY 90 degree jet body 8186WFTG Wall fitting 2a 8184ROTxx StressEaz jet 2b 8184JTB StressEaz jet body 2c 8180NUT StressEaz nut 1 2 3 1b 1a ...

Страница 29: ...erapy option 8000BLW Blower WITH Chromatherapy option 1104BLOWER Blower NO Chromatherapy option 8441FTG 5982MANIFOLD 1 Air check valve assembly 7a 1126xx Suction cover 7b Suction wall fitting 7c Suction elbow 1102 Blower control box NO Chromatherapy option 8075BOX Blower control box WITH Chromatherapy option Option Cable Drive Waste Overflow 8095HEATER Inline Maintenance heater 10 8150UNION 1 5 Pu...

Страница 30: ...Aquatic 1521 No Cooper Ste 500 Arlington TX 76011 3 The Whirlpools Air Baths and Tubs must have been installed and maintained in accordance with good industry practice and the specific Aquatic directions contained in the Owner s Manual and Installation Guide EXCLUSIONS These warranties do not extend to or do not cover defects caused by 1 Shipping damage by carriers or installation errors 2 Acciden...

Страница 31: ......

Страница 32: ...LAOM6 12 12 AQUATIC Fax On Demand System Toll Free 877 618 7024 8101 E Kaiser Blvd Anaheim CA 92808 800 945 2726 Fax 866 544 5353 www aquaticbath com 8MANLUX ...

Отзывы: