Aquatic 35
Serenity Owner's Manual & Installation Guide
TROUBLESHOOTING GUIDE
WARNING:
Always turn off power at the main electrical service panel when servicing your air bath.
SYMPTOMS
POSSIBLE PROBLEMS
SUGGESTED SOLUTIONS
Air bath system does not operate:
1) No power to Air Bath unit.
2) Blower Control is not plugged in.
3) Control Panel connector to controller box is
disconnected.
1) Reset circuit breakers and GFCI if tripped. Check
fuses and replace if bad.
2) Make sure plug is fully inserted into the outlet.
3) Check and reconnect if needed
.
Blower turns off by itself or before
time elapses:
1) Blower motor overheated and thermal protection
device has deactivated motor (possibly low
voltage).
2) GFCI tripped.
1) Check that the blower has sufficient ventilation and
that the intake to the blower is not blocked. Clear
and allow motor to cool down. (check service and
wire size.)
2) Refer to installer/dealer/electrician.
Circuit breaker trips repeatedly:
1) Defective breaker.
2) Short circuit between bath and breaker box.
3) Other items are connected to the same circuit.
1) Contact electrician.
2) Contact electrician.
3) Contact electrician.
Blower does not manually shut off:
1) Defective control panel.
2) Defective blower.
1) Refer to installer/dealer.
Replace control panel.
2)
Refer to installer/dealer. Replace control box.
Air Bath does not function properly
while in the pulse or wave modes.
1) Speed of air setting is set too low.
1) Change the air speed setting to a mid-range setting
before switching to wave or pulse modes.
REPLACEMENT PARTS LIST
ILLUSTRATION NO. PART #
DESCRIPTION
1A.
8162CONTROL
REMOTE CONTROL SERENITY AIR (NON-FREESTANDING)
8161CONTROL
REMOTE CONTROL SERENITY AIR (FREESTANDING)
1B.
(PACKAGED WITH 1A)
REMOTE RECEIVER MODULE CABLE
1C.
REMOTE RECEIVER MODULE
1D.
REMOTE CONTROL MAGNETS
2A.
8162KEYPAD
KEYPAD;BDK;SER AIR/LIGHT;RECT (NON-FREESTANDING)
2B.
8164KEYPAD
KEYPAD;BDK;SER AIR/LIGHT;OVAL (NON-FREESTANDING)
2C.
8161KEYPAD
KEYPAD;BDL;RECT (FREESTANDING)
2D.
8163KEYPAD
KEYPAD;BDL;OVAL (FREESTANDING)
3A.
8130BOX
CHROMATHERAPY CONTROL BOX (SERENITY)
3B.
8020LIGHTS
CHROMATHERAPY;20LEDS BULB;RND CLR
3C.
8LIGHTTOOL
LENS REMOVAL TOOL
3D.
8020LIGHTS
20LEDS CHROMATHERAPY BULB
4A.
8750BLW
BLOWER;750W;VARIABLE;120V;HEATER
4B.
1137
6’ KEYPAD CABLE
5A.
8427FTG
1.5” CHECK VALVE
6A.
1138
WATER DETECTOR CABLE 6FT
6B.
8112SENSOR
WATER DETECTOR PROBE
1136
SENSOR KEYPAD CABLE 25FT
1135
WATER DETECTOR CABLE 25FT
1118
25FT CHROMATHERAPY CABLE EXT.
To indicate color, replace XX with “WH” for White, “BI” for Biscuit , “BO” for Bone