11
©
2007-2009
Aquathin Corporation. All rights reserved. Rev 20091029
3. Planning the Installation
Review the following instructions completely before pro-
ceeding.
(See installation diagrams in Appendix B)
1) Warm the valve to room temperature during cold
weather
During cold weather it is recommended that the installer
warm the main control valve to room temperature before
operating.
2) Select and prepare the location
We encourage you to establish the desired location of
each of the components before proceeding. It is recom-
mended that you install the unit near a clean and working
drain.
Be sure that the area where the water filtration system
will be installed is swept clean before the unit is posi-
tioned for installing to avoid puncture of the storage tank.
If installed outdoors, put down plywood or a concrete
stone in order to provide a flat, even surface for the
MEGACHAR System to be placed upon. (CAUTION:
this unit will crack if allowed to freeze).
4. Connecting the Control Valve to the Media
Tank
1) Lubricate the
distributor o-ring
located by the
control valve
throat as shown
in
figure 2
.
Fig. 2. Lubricate distributor o-ring
with silicone lubricant.