![aquatherm AT400 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/aquatherm/at400/at400_installation-manual_2961210017.webp)
#12 HIGH/SPA
#13 COMMON
#14 LOW/POOL
OR
PR
TN
WH
KEY PAD TERMINAL
DEF.
SENSOR
HIGH
PRESS.
WATER
PRESS.
LOW
PRESS.
T.C.O.
JUMPERS
SEE
NOTE #4
DEG. F
T.C.O.
TEST
COMP.
RELAY
240 VAC
FAN
POOL
SENSOR
Attach the other end of
the 3 wire cable to the
AquaSwitch
as follows:
#12 For the HIGH/SPA
#13 For the COMMON
#14 For the LOW/POOL
If you are using a Jandy AquaSwitch or JI2000 control run a 3 wire cable from the control to the
heater. Remove the 6 screws from the heaters front service access panel and open. Look for the
heater’s solid state circuit board located inside the top portion of the electrical compartment
mounted on the rear wall. Locate the 3 terminals labeled POOL SPA SWITCH. Attach the 3 wire
cable as shown below. Do not remove any jumpers.
Next, attach the 3 wire cable to the
HEATER
to the three terminal positions
labeled POOL SPA SWITCH
LEFT POSITION= LOW/POOL
CENTER POSITION= COMMON
RIGHT POSITION= HIGH/SPA
Attach the other end of the
3 wire cable to the
JI2000
as follows:
#10 For the HIGH/SPA
#11 For the LOW/POOL
#12 For the COMMON
Interfacing “Digital Logic” Digital Control Models with:
Aquaswitch or JI2000
Page 17
NOTE:
The control will switch between pool
and spa thermostats.
Most remote control brands that do not
have a thermostat control will hook up simi-
lar to the Jandy™ products.
(Pool/Comm/Spa or Low,Comm,High)
Note: The pool light on the heater’s key pad will flash
when an external device has control of the heater.
*See wiring diagram on page 10.