![AQUATECH ECO 11000 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/aquatech/eco-11000/eco-11000_user-instructions_2961176004.webp)
1
2
3
4
5
6
7
8
9
Illustration A
The impeller:
Not only to avoid interruptions, but also to ensure a large water capacity, it is important
to clean the impeller regularly. Proceed as follows (see Illustration A):
Switch off the power supply and remove the pump from the pond.
Remove the pump from the housing (pre-filter house) (see illustration B).
Loosen the 4 screws (6).
Remove the impeller housing (9) from the motor housing (1).
Remove the impeller (7) carefully from the motor housing (9).
Clean the impeller under running water with a soft brush.
Clean the impeller housing under running water with a soft brush.
Clean the pump housing carefully under running water with a soft brush.
Assemble all parts in reverse order. Ensure that the impeller is running smoothly in
the motor housing and that the gasket is mounted correctly before you fasten the 4
screws again.
Put the pump back to the pump housing and ensure that all parts and the power
cable are mounted correct. Now the 5 clips can be closed easily.
1
2
3
4
5
6
7
8
9
Illustration A
Spare parts and accessories
No Description
Article No
No Description
Article No
1
Electromotor & housing
AT001280
7
Impeller ECO 11000
AT001267
2
Nuts 4 pcs
AT001282
7
Impeller ECO 14000
AT001269
3
Ceramic bearing
AT001284
7
Impeller ECO 18000
AT001271
4
Gasket
AT001286
7
Impeller ECO 22000
AT001273
5
Motor support
AT001288
7
Impeller ECO 25000
AT001275
6
Bolts / screws 4 pcs
AT001290
8
Gasket
AT001292
7
Impeller ECO 3600
AT001261
9
Impeller housing 3600-11000
AT001294
7
Impeller ECO 4800
AT001263
9
Impeller housing 14000-25000
AT001296
7
Impeller ECO 7200
AT001265
Modeltype
on the pump
housing