background image

W A T E R G A R D E N I N G   T O   T H E   M A X

A Q U A T E C E Q U I P M E N T. C O M

SUBMERSIBLE 

FILTRATION & WATERFALL PUMPS

1.  Clean the housing and pump with a suitable brush, taking care to clean off sludge, algae and debris.

2.  To maintain the impellor of the pump, turn the Impellor Cover in an anti-clockwise direction as indicated by the 

arrow, to the stop position. Then separate the impellor cover from the pump motor body.

3.  Lift out the impellor assembly. (Take care not to break ceramic shaft.) The black disc behind the blades is part of 

the entire impellor assembly. Clean the impellor with clean water and a suitable brush taking note to remove fine 
sediment on and around the back end of the impellor including the small hole through the ceramic shaft if it has one. 
Replace the impellor if necessary.

4.  On some models, in the centre of the impellor, you may notice a small whole opening that protrudes through the 

ceramic shaft from front to back. It is paramount that this portal is kept unblocked at all times. This is a cooling 
channel for the motor.

5.  Ensure to replace the O-Ring in the correct place shown in the picture when reassembling the unit.

IMPORTANT NOTES:

It is important to ensure that this is carried out regularly as the cooling path inside the motor will become clogged. If 
the impellor assembly becomes worn or damaged it should be replaced (available from your dealer or special orders). 
Failure to do so may cause serious damage to pump. Inspect for signs for wear and tear. The impellor set is a wearing 
consumable part.

Once the cleaning and inspection process is completed, reassemble in the reverses manner. Reinstall the impellor into 
the motor body. To place the Impellor O-Ring around the black disc successfully, firmly hold the disc with one hand, and 
using the other hand stretch the O-Ring over the disc, positioning it carefully into the groove. Pay attention not to allow 
the O-Ring 

(4)

 to roll forward, in-between the black disc and the motor body. With the impellor in the correct position, 

carefully place the impellor cover back on, and then rotate clockwise back into position.

For instructions for cleaning of optional Bio-filters check the website for further information. You can help boost the 
biological function of your filtration with a bacterial additive, available from your local PondMAX Dealer.

PMAX PU Pumps Instructions.indd   5

26/7/17   1:03 pm

Содержание PONDMAX PU3500

Страница 1: ...SUBMERSIBLE FILTRATION WATERFALL PUMP INSTRUCTION MANUAL HOTLINE 1300 AQUATEC DATE JULY 2017 v1 0 MODEL PU3500 PU5500 PU7500 PU10500 PU12500 PMAX PU Pumps Instructions indd 1 26 7 17 1 03 pm...

Страница 2: ...gh water flow conversion Eco Friendly Exceptional low dB noise rating with low mechanical vibration Tool less Assembly Easy maintenance No special tools required Soft Start Rotor starts at low speed a...

Страница 3: ...rom the power supply when not in use Never pull the cable to disconnect the plug from the power supply Grasp the plug and pull to disconnect If required have a qualified electrician install a weatherp...

Страница 4: ...your convenence when used under water Select the hosetail Locate the O Ring washer and the locking nut of the hosetail Slide the O Ring then the locking nut over the hosetail connect the threaded loc...

Страница 5: ...wn in the picture when reassembling the unit IMPORTANT NOTES It is important to ensure that this is carried out regularly as the cooling path inside the motor will become clogged If the impellor assem...

Страница 6: ...asket 16 Connection Nut 17 Ball joint Nut 18 Outlet 19 Outlet Nut 20 Motor bracket 21 Baffle 22 Lower filter basket EXPLODED VIEW IMPORTANT These accessories and attachments are recommended for use wi...

Страница 7: ...ll if necessary Blocked Impellor chamber or ceramic shaft is broken Clean the Impellor Check for ware Replace if necessary Water Pump is noisy Blockage in pump Clear the blockage Impellor Shaft worn o...