Installation guide page 3
Fresh water flushing system
Mount the filter housing for the charcoal filter at an easily accessible place between
the fresh water pressure system and the prefilter housing. Install the hose
connections corresponding to the flow diagram.
Preservation and cleaning of the plant by the use of the flushing tank
Mount the included flushing tank in a way that there is a slope to the feed pump and
to the high-pressure pump.
Control panel
.
Mount the control panel with vertical gauge
at an easily accessible place.
It always should be possible to control the hose connections.
High-pressure pump unit
Mount the pump unit horizontally in a cool, even, vibration-free place. A twist of the
base plate must be avoided.
After mounting,
exchange the upper red plastic-srew in
the crankcase for the
dipstick with ventilation
Membrane housing (pressure vessel)
For the installation of the membrane housings athwart ships, inclined or vertical, the
housings have to be secured in the retainers so that they don’t get out of place.
Standard installation is horizontal, but any other angle is possible. For a inclined or
vertical installation, the product water outlet and brine outlet has to be at the top. For
horizontal installation, the fresh water outlet can be mounted at any side of the
membrane housing.
If, for your installation, the delivered fresh water connection on the side of the
seawater outlet does not correspond to the conditions, you can correct that easily by
changing the end caps (Screw tightening torque for the holding clips 3 Nm).
Hose connections pressure vessel
The pressure pipe is sealed with plastic-caps on the high-pressure connections. Der
Produktwasseranschluss ist mit einem Kunststoff-Stopfen verschlossen,
der nach
dem Anschluss der Hochdruckschläuche gegen den mitgelieferten John Guest
Anschluss ausgetauscht wird
. This prevents a drying-out of the membrane which
is impregnated with preservative liquid. The plastic- caps and the plug have not to be
removed until immediately before commissioning to connect the high-pressure hoses
and the product water hose.
Hint:
The membrane can be stored in the sealed pressure pipe for 6 weeks,
preferably cool, but not above 20°C ambient temperature. However, we recommend
to install the watermaker as soon as possible and to put it into operation.
Содержание DC 500
Страница 1: ...User Manual Version 2013 01 Aquatec watermaker DC 500 Modular 12 or 24 Volt DC ...
Страница 5: ...5 Flow diagramm fresh water production Working pressure 55 60 bar ...
Страница 7: ...7 Flow diagram fresh water flushing Working pressure 0 bar ...
Страница 9: ...9 Flow diagram long term preservation mothballing and cleaning Working pressure 0 bar ...