IonGen

Electronic Clarifier for Ponds  

and Pondless

®

 Waterfall Systems

The Aquascape IonGen

 is a 

water clarifier solution for ponds, 

Pondless

®

 Waterfalls, and other 

decorative water features.  The 

IonGen

 drastically reduces pond 

maintenance and provides crystal 

clear water without the use of 

chemicals. A microprocessor inside 

the IonGen

 Control Panel causes 

the outermost atoms of copper, 

silver, and zinc to lose an electron, 

creating a positive ion. The positive 

ion attempts to flow from one of 

the Probe’s bars to the other and 

is swept away by the flow of water 

where the ion can begin to treat the 

water. The IonGen

 Probe is self 

cleaning, using reverse polarity to 

prevent scale and debris build-up 

on the Probe’s bars. The metal 

alloys in the Probe are scientifically 

blended and tested to produce 

maximum results. The IonGen

when used according to the 

manufacturer’s guidelines, is  

safe for fish and plants and is  

not toxic to any animals that  

may drink from the pond.

Congratulations on your purchase of the Aquascape IonGen

.

Installation Instructions & Maintenance Owner’s Manual

A) IonGen

 Control Panel  

(replacement #98943)

B) 2" PVC Flow Chamber  

(replacement #30120)

C) Replaceable IonGen

 Probe 

(replacement #98881)

D) Plug-in Transformer  

(replacement #98375)

 Copper Test Kit –  

not pictured (#98952)

 Ph/Total Alkalinity Test Kit – 

not included, sold separately 

(#98953)

A

B

C

D

Download a QR scanner app for your smartphone,  

then scan this Quick-Response code.

Want to know more about our products  

and the water gardening lifestyle?

Содержание IonGen

Страница 1: ...n Installation Instructions Maintenance Owner s Manual Made in U S A Aquascape Inc St Charles IL 60174 Brampton ON L6T 5V7 www aquascapeinc com Electronic Clarifier for Ponds and Pondless Waterfall Sy...

Страница 2: ...polarity to prevent scale and debris build up on the Probe s bars The metal alloys in the Probe are scientifically blended and tested to produce maximum results The IonGen when used according to the...

Страница 3: ...g the replaceable Probe and overwintering the fitting It is recommended to use a pre filter such as a skimmer prior to the Flow Chamber in order to remove solids and debris that may interfere with the...

Страница 4: ...s output The ionizing light will flash RED when the Probe is exhausted or the Control Panel indicates a problem See Troubleshooting Table for more information on the RED Ionizing light The Replaceable...

Страница 5: ...Flow Chamber Increase pump run time or move Flow Chamber to higher flow location Debris stuck on Probe Remove Probe and clean debris and any scale build up off bars Outside of targeted water parameter...

Страница 6: ...y Serial Number or S N is located on white label on cord Manufacture setting in Control Panel needs to be adjusted Remove back panel of Control Panel and turn the blue potentiometer screw clockwise un...

Страница 7: ...e passion 7 Guide d installation et manuel d utilisation Fabriqu aux tats Unis Aquascape Inc St Charles IL 60174 Brampton ON L6T 5V7 www aquascapeinc com Clarificateur lectronique pour bassins et casc...

Страница 8: ...ent l entartrage et l accumulation de d bris sur les lectrodes L alliage m tallique des lectrodes est scientifiquement dos et test pour donner des r sultats optimaux Le clarificateur IonGenMC lorsqu u...

Страница 9: ...o il y a un bon d bit d eau comme dans le bo tier de l cumoire ou le bord d une cascade Assurez vous que le connecteur des lectrodes atteigne la chambre d ionisation Suivez le guide tape par tape pou...

Страница 10: ...que les taux de cuivre demeurent sous 0 25 ppm Si la concentration de cuivre d passe 0 25 ppm r duisez le clarificateur IonGenMC une barre sur le voyant d ionisation ou d branchez le jusqu ce que les...

Страница 11: ...Remplacez une partie de l eau par de l eau fra che pour faire baisser plus rapidement la concentration de cuivre 7 L eau est trouble importante quantit de d bris D bit d eau insuffisant dans la chambr...

Страница 12: ...trois saisons selon l usage qui en est fait la quantit d eau traiter et les param tres de l am nagement aquatique Le voyant d ionisation qui est normalement au VERT se met clignoter en rouge lorsqu i...

Отзывы: