background image

6

 

US (866) 877-6637 | 

 

CAN (866) 766-3426 | aquascapeinc.com

General Maintenance

•  Pump Cage – Do not remove the upper or lower pump 

cage while operating the pump. Failure to operate the 
pump without the filter cage or operating the pump with 
a broken cage will allow large debris to enter the pump 
causing the pump to fail, thus voiding the warranty.

•  Pump Cage Cleaning – We recommend inspecting 

your pump on a regular basis to ensure it is functioning 
properly. If you notice the water flow rate diminish, it 
may be due to the pump’s filter cage becoming clogged 
with debris (Ex. 13). In many cases the filter can simply 
be pulled from the pond and cleaned of any debris on 
the filter cage. Always disconnect the power before 
performing maintenance on the pump.

•  Remove any debris stuck to the pump filter cage and/or 

use a garden hose to spray off any debris stuck to the filter 
cage (Ex. 14).

•  Internal Pump Cleaning – If you have thoroughly cleaned 

the filter cage screens and still have diminished flow rates, 
then you will need to remove the pump from the lower 
cage and inspect the impeller rotor assembly.

•  Pull the cage release clips outward to unlock the upper 

and lower pump cages (Ex. 15).

•  With the cage clips released, the upper filter cage can be 

lifted to expose the pump (Ex. 16).

Ex. 18

Ex. 15

•  Remove the screws securing the pump restraining 

bracket, allowing the pump to be lifted from the lower 
cage (Ex. 17).

•  For easier pump access, pull the power cord free from the 

strain relief (Ex. 18).

•  Remove the four screws that hold the water cover 

chamber and inspect the impeller rotor assembly (Ex. 19).

•  If your rotor assembly impeller and internal pump body 

have excessive scale build-up, clean with a mild acid, 
such as white vinegar or non-abrasive calcium, lime and 
rust remover product. A sponge or soft-bristled brush that 
won’t scratch the stainless steel can be used at this time 

Ex. 13

Ex. 14

Ex. 16

Ex. 17

Ex. 19

Содержание 91011

Страница 1: ...HANDLING POND PUMP AquaForce 1000 Solids Handling Pond Pump Item 91011 AquaForce 1800 Solids Handling Pond Pump Item 91112 AquaForce 2700 Solids Handling Pond Pump Item 91012 AquaForce 3600 Solids Ha...

Страница 2: ...ase of maintenance makes this pump the ideal choice for discriminating pond owners The AquaForce protective pre filter cage allows the pump to be placed directly into the pond AquaForce pumps are able...

Страница 3: ...all a properly grounded receptacle outlet acceptable for outdoor use and protected from snow and rain B Inspect cord before using C Do not use extension cords D Any wiring of pumps should be performed...

Страница 4: ...ected This pump has been evaluated for use with water only Input amps wattage see chart below Model Number 1000 1800 2700 3600 5200 Maximum Flow Rate GPH 1 070 2 149 2 695 3 868 5 284 Maximum Head Hei...

Страница 5: ...by a ground fault interrupter Ex 10 Once the pump is running and water is circulating check for any leaks where the external connections are made Using the AquaForce as a Winter Bubbler The AquaForce...

Страница 6: ...s stuck to the filter cage Ex 14 Internal Pump Cleaning If you have thoroughly cleaned the filter cage screens and still have diminished flow rates then you will need to remove the pump from the lower...

Страница 7: ...receiving the correct voltage Pump not working The ground fault circuit interrupter GFCI may have tripped The pump is not receiving the correct voltage Troubleshooting Ex 20 Removing scale build up wi...

Страница 8: ...and winterized otherwise warranty is null and void No liability for loss or damage of any nature or kind whether arising out of or from the use of the product whether defective or not defective is ass...

Страница 9: ...N AquaForceMD 1000 Solids Handling Pond Pump R f rence 91011 AquaForceMD 1800 Solids Handling Pond Pump R f rence 91112 AquaForceMD 2700 Solids Handling Pond Pump R f rence 91012 AquaForceMD 3600 Sol...

Страница 10: ...aquascape4 pinterest com aquascapeinc instagram com aquascape_inc Rejoignez nous sur Les pompes pour filtration et cascades AquaForce asynchrones et r sistantes au colmatage effectuent ce que la plupa...

Страница 11: ...de la s curit de l utilisateur E D branchez la pompe de la prise de courant lorsque vous ne vous en servez pas ou avant de la sortir du plan d eau F Pour r duire le risque de d charge lectrique tout...

Страница 12: ...la pompe de bassin de traitement des solides AquaForceMD Tension d entr e 120 V c a Fr quence d entr e 60 Hz Pompe submersible Pour utilisation ext rieure ou int rieure Protection thermique Pompe valu...

Страница 13: ...ascades ou un filtre pressuris Ex 9 Branchez la pompe un disjoncteur de fuite la terre Ex 10 Lorsque la pompe fonctionne et que l eau circule par le s filtre s ou les cascades v rifiez toute possibili...

Страница 14: ...ant les d bris de la cage de filtration Retirez les d bris log s dans la cage de filtration de la pompe et ou utilisez un tuyau d arrosage pour nettoyer les d bris coll s sur la cage de filtration Ex...

Страница 15: ...ension D pannage Si l assemblage de la turbine du rotor et la partie interne de la pompe contiennent des d p ts calcaires excessifs nettoyez avec un acide doux comme du vinaigre blanc ou du CLR et une...

Страница 16: ...a garantie exclut les co ts de main d uvre de retrait du produit d exp dition et les d penses li es l installation et la r installation du produit Tous les produits qui incluent la plomberie tubes pom...

Отзывы: