AquaScape 45009 Скачать руководство пользователя страница 2

2

 

US (866) 877-6637 | 

 

CAN (866) 766-3426 | aquascapeinc.com

Thank you for choosing the AquaSurge

®

 

Adjustable Flow Pond Pump. 

At Aquascape 

our goal is to supply our customers with the best 
valued products in water gardening. We hope 
you enjoy your purchase. Thank you for choosing 
Aquascape. 

Your Paradise. Our Passion.

®

TABLE OF CONTENTS

Introduction ………………………………… 2
Contents  …………………………………… 3
Safety Information …………………………… 3
Specifications Chart ………………………… 4
Installation …………………………………… 4
General Maintenance ……………………… 6
Winter Application …………………………… 8
Troubleshooting ……………………………… 8
Replacement Parts   ………………………… 9
Warranty Information  …………………… 10

AquaSurge

®

 Adjustable Flow Pond Pumps are submersible 

pumps made for continuous use in ponds, Pondless

®

 

Waterfalls, and other water feature applications. 
Asynchronous motor technology provides superior 
reliability and energy efficiency for year after year of reliable 
performance. The included Smart Pump Receiver includes 
an integrated control panel and makes it easy to control 
your pump with the Aquascape Smart Control App. This 
instruction manual will guide you through the proper setup 
and recommended maintenance procedures to ensure 
long-term effectiveness.

AquaSurge

®

 

Adjustable Flow 

Pond Pump

 Contact Us

For more information about our company or products,  
please visit our website at aquascapeinc.com or  
call US (866) 877-6637 CAN (866) 766-3426.

facebook.com/aquascapeinc
youtube.com/aquascape4
pinterest.com/aquascapeinc

Find us on:

Содержание 45009

Страница 1: ... T I O N S M A I N T E N A N C E aquascapeinc com P R O F E S S I O N A L G R A D E 3 Y E AR WARRA N T Y G A R A N TIE DE TRO I S A N S 3 AquaSurge 2000 4000 Adjustable Flow Pond Pump Item 45009 AquaSurge 4000 8000 Adjustable Flow Pond Pump Item 45010 ...

Страница 2: ...s made for continuous use in ponds Pondless Waterfalls and other water feature applications Asynchronous motor technology provides superior reliability and energy efficiency for year after year of reliable performance The included Smart Pump Receiver includes an integrated control panel and makes it easy to control your pump with the Aquascape Smart Control App This instruction manual will guide y...

Страница 3: ...eptacle outlet when not in use or before removal from pond F To reduce risk of electrical shock all wiring and junction connections should be made per local codes Requirements may vary depending on usage and location G The power cable should be protected at all times to avoid punctures cuts bruises and abrasions H Never handle power cords with wet hands I Do not remove cord and strain relief Do no...

Страница 4: ... abuse of pumps or equipment AquaSurge Pond Pump Specifications Input Voltage 120V AC Input Frequency 60 Hz Submersible pump For outdoor or indoor use Thermally protected This pump has been evaluated for use with water only Input Amps Wattage Do not submerge AquaSurge Adjustable Flow Pond Pump directly into the pond The AquaSurge Adjustable Flow Pond Pump is designed to be placed inside a skimmer ...

Страница 5: ...m off the smaller sections to avoid flow restriction Ex 6 Ex 3 Ex 4 Ex 5 1 1 1 Hosetail ready for 1 tubing 1 1 CUT HERE remove Hosetail ready for 1 tubing 1 CUT HERE remove Hosetail ready for 1 tubing stainless steel hose clamp 1 KINK FREE TUBING Installation of stainless steel hose clamp Ex 6 In some instances the tubing may be tight or difficult to connect to the fitting If this is the case we r...

Страница 6: ... for the network to which the unit will connect Ex 12 General Maintenance It is recommended to inspect your pump on a regular basis to make sure it is functioning properly NOTE Always disconnect the power before performing maintenance on the pump Ex 9 Ex 10 Ex 11 Ex 12 NOTE Adequate Wi Fi coverage is required 2 4g networks supported Continue to follow on screen instructions to complete the pairing...

Страница 7: ...he screens before operating the pump as failure to do so may cause the pump to fail voiding the warranty Impeller Rotor Cleaning Remove the four screws to disconnect the water chamber cover Ex 17 Ex 17 Ex 18 Ex 15 Ex 16 Ex 19 Ex 20 Remove the impeller by pulling gently Ex 18 Clean the impeller and internal pump body with Aquascape Pump Cleaner Maintenance Solution 91143 using a sponge or soft bris...

Страница 8: ...lution 91143 to remove excessive buildup Troubleshooting Reduced water flow Check the outer and inner filter screens Pump hums but doesn t push water The pump or plumbing may be clogged Make sure nothing is blocking the intake Clean the inner and outer screens Clean the impeller rotor assembly and internal pump body Make sure the pump is receiving the correct voltage Make sure the impeller blades ...

Страница 9: ... Adjustable Flow Pump Handle Feet Kit 5 45038 Smart Control Receiver 6 45017 AquaSurge 4000 8000 Adjustable Flow Replacement Impeller Kit AquaSurge 4000 8000 Adjustable Flow Pond Pump Replacement Parts 1 1 1 6 3 5 6 3 5 2 4 6 3 5 1 2 4 6 3 5 2 3 6 4 5 NOTE TITLE BLOCK TOLERANCE NOT APPLICABLE A A B B 2 2 1 1 56000 PP 2 SHEET 1 OF 1 UNLESS OTHERWISE SPECIFIED SCALE 1 4 DWG NO A SIZE TITLE CREATED B...

Страница 10: ...ge resulting from negligent handling misuse or lack of reasonable maintenance for care This pump is designed for use in freshwater non chlorinated applications only Warranty is valid against defect due to material and the company s workmanship only The sole obligation shall be to replace the defective unit with a suitable replacement unit Units should be checked for proper operation prior to retur...

Страница 11: ... 4000 Pompe de bassin à débit réglable Référence 45009 AquaSurgeMD 4000 8000 Pompe de bassin à débit réglable Référence 45010 AQUASURGEMD DÉBIT RÉGLABLE POMPE DE POND aquascapeinc com C L A S S E P R O F E S S I O N N E L L E I N S T R U C T I O N S E T E N T R E T I E N ...

Страница 12: ...isation continue dans les étangs les cascades PondlessMD et autres applications de fonctions aquatiques La technologie de moteur asynchrone offre une fiabilité et une efficacité énergétique supérieures pour des performances fiables année après année Le récepteur de pompe intelligent inclus comprend un panneau de commande intégré et facilite le contrôle de votre pompe avec l application Aquascape S...

Страница 13: ...t lorsque vous ne vous en servez pas ou avant de la sortir du plan d eau F Pour réduire le risque de décharge électrique tout le câblage et les raccordements de jonction devraient être exécutés selon les normes locales Les exigences peuvent varier en fonction de l utilisation et de l emplacement G Le câble électrique devrait être protégé en tout temps pour éviter les perforations les coupures les ...

Страница 14: ... d une mauvaise utilisation ou d une utilisation abusive de la pompe ou de l équipement Spécifications de la pompe de bassin AquaSurge Tension d entrée 120 V c a Fréquence d entrée 60 Hz Pompe submersible Pour utilisation extérieure ou intérieure Protection thermique Pompe évaluée en utilisation avec de l eau seulement Intensité de courant d entrée et puissance en watts Spécifications de la pompe ...

Страница 15: ...estriction de débit Ex 6 Ex 3 Ex 4 Ex 5 Dans certains cas le tube peut être serré ou difficile à connecter au raccord Dans ce cas nous vous recommandons de chauffer le tuyau avec un sèche cheveux ou de le plonger quelques secondes dans de l eau très chaude La lubrification peut également être utilisée nous recommandons la graisse de silicone ou l huile d olive Placez le raccord sur la pompe avant ...

Страница 16: ...rez le réseau Wi Fi et le mot de passe du réseau auquel l unité sera connectée Ex 12 Ex 9 Ex 10 Ex 11 Ex 12 REMARQUE Une couverture Wi Fi adéquate est requise 2 4 g réseaux pris en charge Continuez à suivre les instructions à l écran pour terminer le processus de jumelage Pour rétablir les paramètres d usine par défaut éteignez d abord l appareil en appuyant sur le bouton d alimentation puis maint...

Страница 17: ...Nettoyer la turbine et le corps de pompe interne avec la solution d entretien pour nettoyant de pompe Aquascape n 91143 à l aide d une éponge ou d une brosse à soies souples Ex 19 Réinstallez la roue en vous assurant que le joint est en place et que la clé surélevée de la bride de la roue est alignée sur l encoche correspondante sur la face de la bride de la pompe Ex 20 REMARQUE Ne retirez pas les...

Страница 18: ...ions excessives Dépannage Débit d eau réduit Vérifiez les filtres extérieurs et intérieurs La pompe bourdonne mais ne pousse pas l eau La pompe ou la plomberie est peut être bouchée Assurez vous que rien ne bloque l apport Nettoyer les écrans intérieurs et extérieurs Nettoyer le rotor et le corps de pompe interne Assurez vous que la pompe reçoit la tension correcte Assurez vous que les pales de la...

Страница 19: ... à débit réglable 4000 8000 AquaSurge 4 45012 Poignée et pieds prêts à monter pour pompes à débit réglable 4000 8000 AquaSurge 5 45038 Récepteur Smart Control 6 45017 Turbine de rechange prête à monter pour pompes à débit réglable 4000 8000 AquaSurge Pièces de rechange pour pompe de bassin AquaSurge 4000 8000 à débit réglable 1 1 1 6 3 5 6 3 5 2 4 6 3 5 1 2 4 6 3 5 2 3 6 4 5 NOTE TITLE BLOCK TOLER...

Страница 20: ...ce de manutention d une mauvaise utilisation ou de l entretien ou de soins défaillants Cette pompe est conçue pour une utilisation dans les applications d eau douce non chlorées La garantie est valable contre les défauts dans les matériaux et les défauts de fabrication seulement Le remplacement de l unité défectueuse par une unité de rechange appropriée sera la seule obligation Les unités devront ...

Отзывы: