AQ1B Underwater Metal Detector User Manual

9

CARE AND MAINTENANCE

Proper care of your 

Aquapulse

 will be repaid by a long and trouble free life and

attention should be given to the following points: -

1.

 

After use, and before removing plugs, make sure that the unit is switched off,
wash down with clean fresh water.

2.

 

Dry the detector paying particular attention to the area around the plugs.
Clear any excess water by blowing.

3.

 

Recharge the batteries if the total hours used is approaching 10.

4.

 

Never

 leave your 

Aquapulse

 lying in the hot sun, as this could raise the internal

temperature to the point where it may distort the case and harm the electronics.

5.

 

The electronic unit is sealed and pressure tested in the factory, no attempt should
be made to access the electronics.  If any servicing is required, contact your
supplier who will advise you where to send the unit.

BATTERY CARE & CHECKING BATTERY PERFORMANCE/STATUS

The AQ1B internal battery pack is a 7-cell series pack giving a capacity of
approximately 2500mA/Hrs. This capacity relates to an operational period of between
10 and 12 hours from full charge. Note: self-discharge occurs naturally in a
rechargeable battery. During inactivity this self-discharge causes the battery to slowly
discharge itself over a period of months. Nicad batteries can develop a  “memory”
effect through partial charge/discharge cycles; this effect will reduce the effective
capacity available. To maintain maximum performance it is important to regularly
discharge the battery completely followed immediately by a full re-charge.
Periodically, to ensure adequate operational battery duration, or to confirm the status
of your battery, the following checks and procedure should be carried out.

 

Checking Battery Pack Voltage

To test whether or not your battery pack is charged, you may use the following test,
which requires a DC voltmeter. A digital voltmeter is preferred since these voltages
are low and measurement needs to be made in the tenths of a volt resolution.

1.

With nothing connected to the detector, turn the detector ON.

2.

With the detector placed so the printing on the top label is in normal
orientation, place the positive lead of the voltmeter on the TOP pin of the
Loop connector (See diagram).

3.

Place the negative lead of the voltmeter on the TOP pin of the Phone/Charge
connector (See diagram).

4.

 

You should now be able to read the voltage of your battery pack.

Содержание AQUAPULSE 1B

Страница 1: ...quascan Int Ltd all rights reserved This document must not be replicated in whole or part without the prior express permission of Aquascan International Ltd Issue 7 22nd December 2003 AQUASCAN INTERNA...

Страница 2: ...on 4 Initial Testing 5 Underwater Operation 7 Using Arm Saver Kit with 38cm Loop 9 Care and Maintenance 9 Checking Battery Status Performance 12 Troubleshooting Guide 13 Aquapulse 1B System Parts Acce...

Страница 3: ...the following items 1 Sealed electronic unit 2 Bone conductor earphone or Land headphones with cable and plug 3 Search Loop and shaft or Search probe with cable and plug 4 Mains Battery charger 100 25...

Страница 4: ...uld be fully recharged as soon as possible to avoid irreparable damage to the battery cells N B DO NOT USE ANY OTHER BATTERY CHARGER THAN THE ONE SUPPLIED AS DAMAGE TO THE BATTERY PACK MAY RESULT When...

Страница 5: ...setting is increased the detector will reject signals from silver paper ring pulls and other unwanted non ferrous objects 10 Having performed the above checks switch off The Aquapulse is now ready fo...

Страница 6: ...reshold point keeping the search loop at arms length and up from the seabed this avoids detecting any metallic part of the personal diving equipment or any buried items 5 Search by scanning the loop f...

Страница 7: ...er from the Lower Shaft and place the Washer in the recess on the Swivel Connector at the centre of the Loop as shown below Washer in connector recess Nut Bolt Washer 3 Next slide the end of the Lower...

Страница 8: ...ere are three possible securing positions on the Arm Saver so that you can select the one which is more comfortable for you and most suitable for the job you are carrying out 6 The top of the Arm Save...

Страница 9: ...ll charge Note self discharge occurs naturally in a rechargeable battery During inactivity this self discharge causes the battery to slowly discharge itself over a period of months Nicad batteries can...

Страница 10: ...ery pack Battery Test Points Checking Battery Pack Performance Note For routine maintenance this should be carried out every three months The recommended procedure is as follows 1 0 Connect an AQ1B Lo...

Страница 11: ...1 9 If the performance becomes unacceptable after less than what you the operator determine to be an acceptable minimal operational period then the AQ1B Battery Pack needs to be replaced Note If your...

Страница 12: ...is good policy to firstly check the multi meter s reading with the leads shorted together this provides a measure of what residual reading to take into account See AQ1B Resistance Chart below Item Res...

Страница 13: ...enabling the diver to clearly hear the change in the Detector tone when metal is sensed Comes with extendable flexible cable which allows more freedom of movement with the Bonephone whilst underwater...

Страница 14: ...llows the sense head to be swung over a wide arc for good search coverage Locks into one of three Arm Saver positions to optimise the overall length AQ 4 080 20cm 8 Loop with Stem Fully Waterproof com...

Страница 15: ...AQ1B detector The extended length of cable allows the sensing loop to be slowly towed behind a boat or simply lowered down for drift searching This system of operation allows metallic contact areas t...

Страница 16: ...adjustment for audio detection threshold The primary control is the rotary on off power control which also provides an element of rejection as it is rotated clock wise this is primarily intended for t...

Страница 17: ...or to arrange a repair please use the following contact information Mailing Address Aquascan International Limited Aquascan House Hill Street Newport South Wales NP20 1LZ United Kingdom Tel 44 0 1633...

Страница 18: ...on will lose it s authority Equipment description Marine Metal Detector Model Aquapulse 1B Manufacturer Aquascan International Ltd Aquascan House Hill Street Newport NP20 1LZ S Wales Tel 44 0 1633 841...

Отзывы: