background image

AQ1B Compact Underwater Metal Detector 

User Manual 

N.B. THE CHARGERS SUPPLIED WITH THE AQ1B-Compact ARE FULLY 

AUTOMATIC, AND HAVE A COLOURED INDICATOR THAT SHOWS 
THE STATUS OF THE CHARGER. AFTER CONNECTING, IT TAKES A 
FEW SECONDS TO ANALYZE AND START CHARGING. 

 

 

COLOUR

 

 

 

 

MODE

 

 

YELLOW    BATTERY 

NOT 

CONNECTED 

 

YELLOW    INITIALISATION 

AND 

ANALYSIS 

 

ORANGE    FAST 

CHARGE 

 

GREEN WITH INT. YELLOW 

TOP-OFF CHARGE 

 

GREEN 

    TRICKLE 

CHARGE 

 ALT. 

ORANGE/GREEN    ERROR 

 
 

The batteries will not be damaged by being left on charge for a longer period 
than necessary due to the controlled charge current (14hr rate followed by a 
trickle charge).  If the batteries become fully discharged - due to natural usage 
for the maximum operating period or through the unit accidentally being left in 
the on state – the unit should be fully recharged as soon as possible to avoid 
irreparable damage to the battery cells (see above for charging from a 
discharged state). 

 

N.B. DO NOT USE ANY OTHER BATTERY CHARGER THAN THE ONE 

SUPPLIED AS DAMAGE TO THE BATTERY PACK MAY RESULT.

 

 
2.  When the charge period has elapsed, disconnect the AC supply to the charger 

first

, and then unplug the connector from the socket on the detector. 

 
3.  Plug in the connector on the search loop into the LOOP socket and screw down 

the retaining collar.  This should be good finger tightness only.

  

NOTE:  over-

tightening or connecting the Ikelite connector without the rubber seal can 
damage either the plug or the socket.

 

 

Note:  This plug can only be inserted one way round due to the polarising pin

 
4.  Plug the connector on the Bonephone (or headphone) lead into the PHONE & 

CHARGE socket and screw down the collar as above. NB. For testing on land the 
headphones – if available - are much easier to work with.  

 
5.

 

Hold the search loop well away from any metal and switch the unit on by rotating 
the REJECT control to the MIN position (first position clockwise from OFF).  If a 
continuous sound is heard immediately, the SET AUDIO control should be rotated 
anticlockwise until the audio threshold is reached; this is indicated by a low 
frequency ticking sound. Alternatively, if the unit is initially silent, the SET 
AUDIO control should be turned clockwise to reach the audio threshold.  The 
audio can be set so that a normal slow ticking sound is heard, or alternatively set 
slightly below the threshold so that operation is initially silent.   

Содержание AQ1B

Страница 1: ...44 1633 841117 Fax 44 1633 254829 Email info aquascan co uk Website www aquascan co uk AQUAPULSE 1B Compact UNDERWATER METAL DETECTOR Operating Instructions This manual is copyright 2011 Aquascan Int...

Страница 2: ...g 6 Underwater Operation 8 Detection Interpretation Using Arm Saver Kit with 38cm Loop 11 Care and Maintenance 12 Checking Battery Status Performance 15 Troubleshooting Guide 16 Aquapulse 1B Compact S...

Страница 3: ...009 the new MINI version of the AQ1B was introduced this replaced the previous AQ1B version The AQ1B Compact is the same detector technology as in the past but with some improvements New smaller light...

Страница 4: ...pact Detector 1 Charging the batteries The AQ1B Compact is supplied only partially charged and will require a full 14 hours charging duration to bring the unit to a fully charged status Make sure the...

Страница 5: ...the AC supply to the charger first and then unplug the connector from the socket on the detector 3 Plug in the connector on the search loop into the LOOP socket and screw down the retaining collar Th...

Страница 6: ...the OFF position will give maximum sensitivity to small gold rings and thin section foils As the setting is increased by turning the control clockwise from settings 2 through 6 the detector will rejec...

Страница 7: ...if no hood is worn it can be placed under the strap of the facemask or under a suitable neoprene headband Position the Bonephone so that it is on a bony part of the head close to the ear NOTE NEVER P...

Страница 8: ...eing obtained when the head is centred over the object The shallower the object the more pronounced the peak response will be whereas deeper objects tend to give a more gradual change in response as t...

Страница 9: ...Washer from the Lower Shaft and place the friction Washer in the recess on the Swivel Connector at the centre of the Loop as shown Washer in connector recess Nut Bolt Washer 3 Next slide the end of t...

Страница 10: ...e carrying out 6 The top of the Arm Saver is designed to secure the operators arm and the AQ1B Module with the Velcro straps supplied The module is placed so that the Velcro on the body mates with the...

Страница 11: ...t Care and Maintenance Proper care of your Aquapulse will be repaid by a long and trouble free life and attention should be given to the following points 1 After use and before removing plugs make sur...

Страница 12: ...ill advise you where to send the unit If you ever notice any of the screws becoming loose on the control unit they should be tightened immediately Battery Care Checking Battery Performance Status The...

Страница 13: ...t for a14 hour period The mains re charger supplied has an intelligent sensing device that senses the battery state and will revert to a low current charge once the battery state is sensed as fully ch...

Страница 14: ...h a new battery pack the operation time from a fully charged state should be in the range of 8 to 10 hours If the performance becomes unacceptable after less than what you the operator determine to be...

Страница 15: ...stly check the multi meter s reading with the leads shorted together this provides a measure of what residual reading to take into account See Aquapulse Resistance Chart below Item Approx Resistance o...

Страница 16: ...d 25cm 10 Kit Consists of Control Module Quick Release Harness Bonephone Battery Charger 20cm 8 Loop with Extendable Handle This version has a slightly more powerful sensing loop than the 20cm kit and...

Страница 17: ...ilst underwater enabling the diver to clearly hear the change in the Detector tone when metal is sensed The AQ 4 062 is supplied with an extendable flexible cable which allows more freedom of movement...

Страница 18: ...lows the sense head to be swung over a wide arc for good search coverage Locks into one of three Arm Saver positions to optimise the overall length AQ 4 080 20cm 8 Loop with Stem Fully Waterproof comp...

Страница 19: ...e 65ft length of re enforced cable and standard Ikelite connector for direct compatibility with a standard AQ1B detector The extended length of cable allows the sensing loop to be slowly towed behind...

Страница 20: ...r switch which also provides an element of rejection as it is rotated clock wise this is primarily intended for the rejection of ring pulls during beach search applications or to accommodate excessive...

Страница 21: ...equipment or to arrange a repair please use the following contact information Mailing Address Aquascan International Limited Aquascan House Hill Street Newport South Wales NP20 1LZ United Kingdom Tel...

Страница 22: ...ration will lose its authority Equipment description Marine Metal Detector Model Aquapulse 1B Compact Manufacturer Aquascan International Ltd Aquascan House Hill Street Newport NP20 1LZ S Wales Tel 44...

Отзывы: