background image

Organic chemicals included by surrogate testing

VOCs (by surrogate testing  
using chloroform)  

Drinking water regulatory level 
(MCL/MAC) mg/L

Influent/
Unfiltered

Effluent/
Filtered

Percent 
Reduction

alachlor 

0.002

0.050

0.001

>98%

atrazine

0.003

0.100 

0.003

>97%

benzene

0.005

0.081 

0.001

>99%

carbofuran

0.04

0.190 

0.001

>99%

carbon tetrachloride

0.005

0.078

0.0018

98%

chlorobenzene

0.1

0.077 

0.001

>99%

chloropicrin

0.015

0.0002

99%

2,4-D

0.07

0.110

0.0017

98%

dibromochloropropane (DBCP) 

0.0002

0.052 

0.00002

>99%

o-dichlorobenzene

0.6

0.080 

0.001

>99%

p-dichlorobenzene

0.075

0.040 

0.001

>98%

1,2-dichloroethane

0.005

0.088

0.0048

95%

1,1-dichloroethylene

0.007

0.083 

0.001

>99%

cis-1,2-dichloroethylene

0.07

0.170   

0.0005

>99%

trans-1,2-dichloroethylene

0.1

0.086 

0.001

>99%

1,2-dichloropropane

0.005

0.080 

 0.001

>99%

cis-1,3-dichloropropylene

— 

0.079 

0.001

>99%

dinoseb

0.007

0.170

0.0002

99%

endrin

0.002

0.053

0.00059

99%

ethylbenzene

0.7

0.088 

0.001

>99%

ethylene dibromide (EDB) 

0.00005

0.044 

0.00002

>99%

haloacetonitriles (HAN)
bromochloroacetontrile

0.022

0.0005

98%

dibromoacetontrile

0.024

0.0006

98%

dichloroacetontrile

0.0096

0.0002

98%

trichloroacetontrile

0.015

0.0003

98%

haloketones (HK)
1,1-dichloro-2-propanone

0.0072

0.0001

99%

1,1,1-trichloro-2-propanone

0.0082

0.0003

 96%

heptachlor (H-34, Heptox)

0.0004

0.025 

0.00001

>99%

heptachlor epoxide

0.0002

0.0107

0.0002

98%

hexachlorobutadiene

0.044 

0.001

>98%

hexachlorocyclopentadiene

0.05

0.060 

0.000002

>99%

lindane

0.0002

0.055 

0.00001

>99%

methoxychlor

0.04

0.050 

0.0001

>99%

pentachlorophenol

0.001

0.096 

0.001

>99%

simazine

0.004

0.120 

0.004

>97%

styrene 

0.1

0.150 

0.0005

>99%

1,1,2,2-tetrachloroethane 

0.081 

0.001

>99%

tetrachloroethylene

0.005

0.081 

0.001

>99%

toluene

1

0.078 

0.001

>99%

2,4,5-TP (silvex) 

0.05

0.270

0.0016

99%

tribromoacetic acid

0.042 

0.001

>98%

1,2,4-trichlorobenzene

0.07

0.160 

0.0005

>99%

1,1,1-trichloroethane

0.2

0.084

0.0046

95%

1,1,2-trichloroethane

0.005

0.150 

0.0005

>99%

trichloroethylene

0.005

0.180 

0.0010

>99%

trihalomethanes (THMs)

Influent/
Unfiltered

Effluent/
Filtered

Percent 
Reduction

bromodichloromethane (THM)

0.080

0.300

0.015

95%

bromoform (THM)
chloroform (THM)
chlorodibromomethane (THM)
xylenes (total)

10

0.070 

0.001

>99%

Filter is only to be used  

with cold water. 

Filter usage must comply  

with all state and local laws.

Testing was performed under standard laboratory 

conditions, actual performance may vary. 

Systems certified for cyst reduction may be used on 

disinfected waters that may contain filterable cysts. 

See owner’s manual for general installation conditions and 

needs plus manufacturer’s limited warranty.

Do not use with water that is microbiologically  

unsafe or of unknown water quality without adequate 

disinfection before or after the system.

This system has been tested according to NSF/ANSI 42, 53 & 401 for reduction of the substances listed below. The 
concentration of the indicated substances in water entering the system was reduced to a concentration less than or 
equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53 & 401. 

NSF/ANSI 42

Minimum 
Reduction

Overall % 
Reduction

Results

Chlorine Reduction,  
Free Available

<0.5 mg/l 96.06%

Pass

Chloramine Reduction,  
Free Available

<0.5 mg/l 96.06%

Pass

Particulate Reduction

85%

99.9%

Pass

NSF/ANSI 53

Minimum 
Reduction

Overall % 
Reduction

Results

Cyst Live Cryptosporidium & Giardia 99.95%

>99.95%

Pass

Mercury Reduction pH 8.5

<2 ug/L

>96.7%

Pass

Mercury Reduction pH 6.5

<2 ug/L

>96.6%

Pass

Lead Reduction pH 6.5

<10 ug/L

>99.3%

Pass

Lead Reduction pH 8.5

<10 ug/L

>99.4%

Pass

MTBE Reduction 

<5 ug/L

91.2%

Pass

Turbidity

<0.5 NTU

99.1%

Pass

VOC Surrogate Test 

95%

95%

Pass

Asbestos Reduction 

99%

>99%

Pass

NSF/ANSI 
401

Maximum 
Concentration 

Minimum 
Reduction 

Overall % 
Reduction

Results

Phenytoin

30 ng/L

95.50%

95.6%

Pass

Ibuprofen

60 ng/L

95.3%

95.4%

Pass

Naproxen

20 ng/L

96.3%

96.4%

Pass

Estrone

20 ng/L

96.30%

96.5%

Pass

Bisphenol A

300 ng/L

98.80%

98.9%

Pass

Nonyl phenol

200 ng/L

97.50%

97.5%

Pass

• All contaminants reduced by this filter are listed. 
• Not all contaminants listed may be present in your water. 
• Does not remove all contaminants that may be present in tap water.

Performance Data Sheet for the Aquasana Clean Water Machine

Models

Replacement

Rated capacity

Operating  
pressure range

Operating  
temp. range

Rated 
flow

AQ-CWM-RB1, AQ-CWM-RB2, AQ-CWM-RB1W, AQ-CWM-P-W, AQ-

CWM-P-B, AQ-CWM-D-W, AQ-CWM-D-B, AQ-PCBK-GC, AQ-PC-GC

AQ-CWM-R-D, 
AQ-CWM-R-R

320 gallons 
1200 liters

20-70 psi 
137-482 kPa

40-90° F   
4.44-32.2° C

0.5 gpm 
1.8 lpm

Manufactured by: Aquasana, Inc.

 6310 Midway Road · Haltom City, Texas 76117 · 866.662.6885

System tested and certified by NSF International against 

NSF/ANSI Standard 42, 53 and 401 for the reduction of 

the claims specified on the Performance Data Sheet and 

at www.nsf.org.

Aquasana offers an extensive assortment of water filters and vessels to complement a healthy lifestyle.

aquasana.com

Filter Bottles

Premium Glass Bottles

Whole Home Filters and Salt-Free Softeners

Shower Filtration

Содержание AQ-CWM-D-B

Страница 1: ...THE CLEAN WATER MACHINE Set Up Instructions Get Help 866 662 6885 support aquasana com Quick Start Insert filter before using Flush one cycle before drinking ...

Страница 2: ...or the Water for Life auto ship program Replacement filters come with FREE shipping A 15 discount A System warranty as long as you re enrolled It s free to join and you can unsubscribe at any time 1 866 662 6885 aquasana com water4life SAVE TIME AND MONEY Slide lid right to lift off Filter Insert the filter Replace lid by sliding left Plug into outlet Release button early to avoid spills Place firml...

Страница 3: ...led Use only with cold water Children should not operate without supervision Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts Operating Specs Temp range 40 90 F 4 44 32 2 C Rated flow rate 0 5 gpm 1 8 lpm Capac...

Страница 4: ...h cold water through drop shaped opening Place pitcher on filtration dock until locked in It will automatically filter and run until center reservoir is empty Wait for blue light to turn off Remove pitcher and discard water Flushing is complete WATER DISPENSE BUTTON Please note Water may leak from circular valve when placing dispenser onto dock It may take 2 4 MINUTES or more for water to begin fl...

Страница 5: ...lter is Healthy BLINKING RED Filter 80 Capacity ORDER NOW SOLID RED Filter 100 Capacity REPLACE TALK TO A WATER EXPERT 1 Year Limited Warranty What is Covered This Warranty covers defects in materials or workmanship in manufacturing of your Aquasana drinking or shower water filter systems except as provided below For How Long This warranty runs for 365 days from the date of purchase by a consumer ...

Страница 6: ...fied for cyst reduction may be used on disinfected waters that may contain filterable cysts See owner s manual for general installation conditions and needs plus manufacturer s limited warranty Do not use with water that is microbiologically unsafe or of unknown water quality without adequate disinfection before or after the system This system has been tested according to NSF ANSI 42 53 401 for re...

Страница 7: ...6 662 6885 USA 877 332 7873 Canada www aquasana com System tested and certified by NSF International against NSF ANSI Standard 42 53 and 401 for the reduction of the claims specified on the Performance Data Sheet and at www nsf org cwm noBT_install_20160711 ...

Отзывы: