Calculation of pressure drops
The values of total static pressure drop can be calculated by adding up the losses
from individual elements built into the air pipeline system and the internal static
pressure. The values of static pressure drops of individual elements (static pressure
drops of elements relate to the internal diameter ø125mm or
□
150x70mm) are shown
in
Table no. 2
.
Table no. 2:
Types of elements and corresponding pressure loss values
Flexible pipe according to DN 125
Spiral ribbed pipe DN 125
Diagram 2:
Value of the static pressure drop for selected pipes
Type of element
Value of static pressure loss
a.) Spiral ribbed pipe
Diagram 2
b.) Rectangular pipe □150x70 mm
Diagram 2
(according to DN 125)
c.) Rectangular elbow
-
horizontal 90°
5 Pa
d.) Elbow 90°
4 Pa
e.) Angular reducer ø125 to □150x70
5 Pa
f.) Rectangular elbow
-
vertical 90°
5 Pa
g.) Elbow 45°
3 Pa
h.) Reducer ø125 to □150x70
3 Pa
i.) Flexible tube
Diagram 2
j.) Air intake grid
25 Pa
P
re
ss
u
re
d
ro
p
[
P
a/m
]
Volumetric air flow [m³/h]
Содержание PAW-DHWM 80-120 ZNT
Страница 1: ...PAW DHWM 80 120 ZNT ...
Страница 24: ...24 EN ...
Страница 48: ...48 DE reparieren sondern nehmen Sie mit dem nächsten autorisierten Kundendienst Kontakt auf ...
Страница 120: ...120 DA ...
Страница 144: ...144 NO ...
Страница 168: ...168 SV ...
Страница 192: ...192 HR BIH ...
Страница 216: ...216 CS ...
Страница 240: ...240 HU ...
Страница 264: ...264 PL ...
Страница 267: ...267 ...
Страница 268: ...09 2014 479748 ...