AquaPRO 62041 Скачать руководство пользователя страница 2

 

PERFORMANCE 

 

Model 

HP 

GPM of Water @ Total  

Discharge Pressure of 30 psi 

Max. Pressure  

0 ft. 

5 ft. 

10 ft. 

15 ft. 

20 ft. 

25 ft. 

62041 

3/4 

10 

9.4 

8.8 

8.0 

6.8 

5.4 

66PSI 

 

SAFETY INSTRUCTIONS 

1.Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence of 

flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion or fire, resulting in 

property damage, serious personal injury, and/or death. 

2.ALWAYS disconnect the power to the pump before servicing. 

3.Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not 

disassemble the motor housing. 

4.Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water before 

disconnect the power. 

5.Release all pressure and drain all water from the system before servicing any component. 

6.Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal 

injury, and/or property damage. 

7.Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening safety 

hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension cord to power this 

pump is not permitted. 

8.Wear safety goggles at all times when working with pumps. 

9.This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved 3-conductor cord 

and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The 3-prong plug must be directly 

inserted into a properly installed and grounded 3-prong, grounding-type receptacle. Do not use this pump with a 2-prong 

wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI outlet) installed in accordance 

with the National Electrical Code and local codes and ordinances. All wiring should be performed by a qualified electrician. 

10.Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use 

damaged or worn cords. 

11.Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO USE 

ADAMAGED PUMP can result in property damage, serious personal injury, and/or death. 

12.Ensure that the electrical circuit to the pump is protected by a 20 Amp fuse or circuit breaker. 

13.Do not lift the pump by the power cord. 

14.Know the pump and its applications, limitations, and potential hazards. 

15.Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping the 

pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature failure. 

16.Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand, and 

debris. Disconnect the pump from the power supply before inspecting. 

17.Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all Occupational 

Safety and Health Administration (OSHA) guidelines must be followed. 

18.The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset itself 

once the motor cools down and an acceptable temperature has been reached. The pump may start unexpectedly if it is 

plugged in. 

19.Ensure the electrical power source is adequate for the requirements of the pump. 

Содержание 62041

Страница 1: ...UAL Automatic Booster Pump Questions problems missing parts Before returning to the store call AQUAPRO Customer Service 8 a m 6 p m EST Monday Friday 1 844 242 2475 2015 Copyright GP Enterprises Co Ltd Model 62041 ...

Страница 2: ...talled and grounded 3 prong grounding type receptacle Do not use this pump with a 2 prong wall outlet Replace the 2 prong outlet with a properly grounded 3 prong receptacle a GFCI outlet installed in accordance with the National Electrical Code and local codes and ordinances All wiring should be performed by a qualified electrician 10 Protect the electrical cord from sharp objects hot surfaces oil...

Страница 3: ...through cavitation Make sure that there are no air leaks or air pockets in the suction pipe An air leak in the suction pipe may draw air in although no water leaks out Air leaks and air pockets will prevent the pump from priming properly and can substantially reduce its performance The pump mount should be level solid as near as possible to the water source and protected against excess moisture an...

Страница 4: ...ower cord must reach a power outlet the controller s LED lights must be visible ease of plumbing space saving NOTE Installation of a low pressure safety cutoff switch on the pump discharge is recommended and may be required by your local code to shut off the power in case of low discharge pressure caused by broken pipe etc 2 Mount the pump on a solid base in the location you have decided on 3 Choo...

Страница 5: ...on the main water supply line between the two tees Point them toward the pump CAUTION Risk of burst hose and flooding Do not install with flexible hoses Use only rigid piping that meets code 9 Install piping from tees to pump including a union and ball valve in each line an elbow in the discharge line and a check valve in the pump suction line The arrow on the check valve must point to the pump su...

Страница 6: ...let and inlet ELECTRICAL CONNECTION WARNING Hazardous voltage Risk of dangerous or fatal electric shock Plug the pump into a 115 Volt 60 Cycle Ground Fault Circuit Interrupter GFCI protected grounded outlet only The pump is equipped with a 3 wire grounded cord and plug Do not modify or remove the plug Make sure the outlet meets the National Electric Code or the Canadian Electrical Code as applicab...

Страница 7: ...ycling when water faucets are being turned on and off quickly for example when brushing teeth etc Pressure Drop No Flow Normally when the pump starts it will very quickly generate pressure and sense flow If there is no flow and the pressure does not rise it senses a no water condition It can also sense this during operation if the water supply to the pump fails To protect the pump from running dry...

Страница 8: ...rough system 1 Improper priming 2 Clogged water filter 3 Discharge valve closed 4 Pipe size too small 5 Impeller is plugged 6 Pipes are frozen 1 Re prime according to instructions 2 Stop pump shut off water and change filter cartridge Filter should be installed on discharge side of pump 3 Open valve 4 Re pipe using pipe of the same size as suction and discharge ports on pump 5 Clean impeller 6 Tha...

Страница 9: ... cost of shipping will be paid one way This warranty does not apply to products purchased outside of the United States including its territories and possessions outside of U S Military Exchange and outside of Canada This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of AQUAPRO products OTHER IMPORTANT TERMS This warranty is not tra...

Страница 10: ...10 Questions problems missing parts Before returning to the store call AQUAPRO Customer Service 8 a m 5 p m EST Monday Friday 1 844 242 2475 ...