Maintenance

Machine maintenance 

Some components of your system have a 
limited life span and will need to be replaced. 
The precise duration will depend on the 
quality of the local water, the total amount 
of water consumed, the pattern of usage, 
and specific characteristics of the water 
to be treated such as high chlorination or 
excess hardness, etc. The below maintenance 
guidelines are indicative. Please consult the 
local dealer for further information.

Observe:

 Before performing work on 

electrical components or opening 
the housing, it is mandatory that the 
mains plug be pulled and both the 
water infeed and the permeate line 
be closed off in order to guarantee 
that the system is voltage-free.

Whenever maintenance is performed, 
the connection lines and the device 
must be checked for damage.

Recommended maintenance

 

-

Replace filter 1 and 2 at least every  
12 months.

 

-

Replace filter 3 approximately every  
2 years.

 

-

Sanitize the unit upon commissioning and 
at least every 12 months depending on 
use. Also, sanitize each time components 
in contact with water are accessed, or if 
no water has been consumed for more 
than a month.

 

-

You can clean your system using a moist 
cloth and a mild cleaning agent. To protect 
the surfaces of the unit, do not use any 
bleach, solvent, or alcohols.

 

-

Maintenance must be carried out by 
trained personnel, who must handle the 
equipment properly, as well as use original 
spare parts to maintain the characteristics, 
warranty, certifications, and performance 
of the equipment and thus ensure the 
quality of the water dispensed.

 

-

All filter replacements are supplied 
in individual packaging designed 
to guarantee hygienic storage and 
transportation conditions. Exercise 
precautions to maintain hygiene after 
removing the filters from their packaging 
and when handling the various connectors 
and equipment components.

 

-

Ensure that all joints are kept tightened 
and that the original hydraulic 
configuration of the system is kept as 
recommended.

 

-

If you have any other questions, please 
consult the local dealer.

Disposal

Procedure: The The A2O Pure, 
UTS-800 device consists of 
various materials which need to 
be disposed of properly.
Please contact your contract 
partner for an expert and 
environmentally friendly disposal.

Any electronic parts should be 
disposed of only at authorized 
recycling centers (2012/19/EU). 
Observe the applicable national 
regulations on disposal of electric 
devices.

Содержание A2O Pure

Страница 1: ......

Страница 2: ...A2O Pure UTS 800 Use and installation manual 2 ...

Страница 3: ...Aquaporin com installation or contact the store where you bought your machine A2O Pure Use and installation manual Control via app 4 About A2O Pure 5 Dimensions and weight 9 List of included components 10 Installation scheme 11 How to install 12 Operating instructions 21 Replacement of cartridges 24 Maintenance 27 ...

Страница 4: ...es Receive recommendations to ease the use of your A2O purifier and get a reminder when it s time to change filters Track usage Creates transparency between you and your A2O purifier by allowing tracking of your water usage Monitor filter lifetime next maintenance and the effectiveness of the purification of the purifier Access information Access manuals installation guides and useful information ...

Страница 5: ...ry membrane technology to remove PFAS heavy metals microplastics bacteria viruses hormones nitrates limescale and other harmful substances Input water limitations Feedwater temperature min max 5 25 C Inlet pressure min max 1 6 bar Feedwater Quality Municipal tap water System technical details A2O Pure Model Name UTS 800 Product Category Under the sink Filter cartridges Number Name Material Lifetim...

Страница 6: ...shing auto cleaning Yes Feedwater permeate and wastewater connections 3 8 1 4 1 4 inch Dimensions W D H 315 203 427 mm Weight 8 57 kg Compliance CE EUFCM 1 The flow rate is tested at 25 C lower water temperatures will reduce the flow rate 2 The system is influenced by feedwater conditions such as pressure temperature TDS levels and hardness The better these incoming conditions the better performan...

Страница 7: ...id personal injury or extensive damage to property Observe Underlines useful recommendations and information for an efficient operation free of any interruptions Warranty and disclaimer Observe The information and instructions contained in the manual were compiled based on current standards and regulations the state of the technology our experiences and observations The warranty is void in any of ...

Страница 8: ...ce Observe Improper installation of the system may cause damage to it Observe any country specific installation regulations such as DIN 1988 EN 1717 general hygienic conditions and technical data for protecting the drinking water Unauthorized modifications to the system and technical alterations are not permitted Avoid mechanical damage to the system Otherwise the warranty is void Install a stop v...

Страница 9: ...A2O Pure UTS 800 Use and installation manual 9 Dimensions and weight Net weight 8 57 kg 427 mm 315 mm 315 mm 203 mm 203 mm ...

Страница 10: ...ns may occur please check with your local dealer 1 DRAIN CLAMP KIT Drain clamps 1 Screw nut 2 Gasket 1 Pressure reducer incl check valve 1 Tools required for installation 11 mm key or flexible spanner Flat and Phillips screwdriver Pincer Electrical drilling machine 6 mm and 12 mm drill Faucet 1 Spacer 1 Upper white gasket 1 Lower black gasket 1 Plastic nut 1 2C 7 6 2B 5 2A 4 1 3 8A 8B 8D 8C 8E ...

Страница 11: ...allation manual 11 Wastewater Inlet water Pure water Pure water Water source Inlet water tap water The pressure reducer including check valve for backflow prevention must be applied Faucet Drain pipe Wastewater Installation scheme ...

Страница 12: ... used for multiple connections so use only what you need for each connection and save the remaining for later installation steps When you cut the PE pipes be aware that the pipe is not compressed when you insert it into connections Before installation remove the white IN and OUT plugs as well as the DRAIN plug Keep the plugs as they will be reused if the device is relocated How to remove the plugs...

Страница 13: ...ain installation Drill ø 6 mm 2A 2B 2C Add the gasket between the drain clamps and the drain pipe Gasket 2 5 4 3 5 4 5 Insert the 1 4 PE pipe so that approximately 2 cm will be going into your drain pipe Tighten the clamp with the Phillips screwdriver 2 cm ...

Страница 14: ...A2O Pure UTS 800 Use and installation manual 14 Wastewater 5 5 Cut the 1 4 PE pipe to fit the installation and insert it into the wastewater connection on the machine 4 ...

Страница 15: ...manual 15 Inlet installation 1 6 2 6 3 6 Unscrew the nut from the ball valve Insert the 3 8 pipe onto the ball valve Tighten the nut with a flexible spanner 5 4 6 Cold water pipe Connect the T piece with ball valve on your cold water pipe 7 ...

Страница 16: ... new 5 cm piece of 3 8 PE pipe at the other end of the pressure reducer Note that the direction of the pressure reducer The arrow should be pointing towards the A2O away from the inlet water ball valve Blue Yellow 5 3 6 6 Cut the length of the 3 8 PE pipe to fit your installation Insert the 3 8 mm PE pipe to inlet water on A2O Inlet water 5 ...

Страница 17: ... Use and installation manual 17 Faucet installation 1 3 Drill ø 12 mm Drill a hole adjacent to your regular faucet 2 3 3 3 Assemble and tighten with your hands no use of tools Remove the rubber cover from the faucet 8C 8D 8E 8A 8B ...

Страница 18: ...h the push in fitting onto the bottom end of the faucet Insert a new piece of the 1 4 PE pipe in the other end of the push in fitting Cut the length of the 1 4 PE pipe to fit your installation and insert it into the pure water connection on the machine 1 2 2 2 6 8 4 Pure water ...

Страница 19: ...A2O Pure UTS 800 Use and installation manual 19 Connect A2O Pure to your power supply Connect power 2 2 Turn on the water WARNING Check for leakages before proceeding TURN ON 1 2 ...

Страница 20: ...n the top panel stop blinking open your faucet and check for leakages After installing your A2O Pure or replacing the cartridges the system must be flushed before consuming the water note that the first water coming out will be black As our DWRO membranes are constantly improving in quality and technology we advise you to find the updated flushing times at www aquaporin com or contact your local d...

Страница 21: ...llation manual 21 Operating instructions Water making indicator light Pre filter life indicator Select reset Post filter life indicator DWRO membrane life indicator Fault indicator WIFI indicator User interface overview Rinse button ...

Страница 22: ... In any rinsing state if the user needs to make water the water must be made first and the remaining rinsing actions to be continued after the water has been prepared Select button Filter selection mode Press and hold the select button for 5 seconds a short buzzer will sound in the filter selection mode By default the first level filter Again after a short click on the select button the next choic...

Страница 23: ...ater pump continuous work reminder continuous water production for 30 minutes the buzzer beeps 15 times and the machine enters the long term water production protection mode It can not make water Unplug the power cord and plug it in again to restore WiFi description Press and hold the Clean button until the WiFi icon light flashes Select your A2O Pure in your app then click connect Once the light ...

Страница 24: ...r and contaminants and polishes the taste of the final purified water The three filters remove particles such as sand dirt and other sediments down to 5 microns and it reduces most drinking water contaminants to a high degree including PFASs heavy metals microplastics bacteria viruses dissolved salts and hardness The cartridge replacement intervals are indicative only when the condition is affecte...

Страница 25: ... Remove the cover and identify the cartridge that needs to be replaced Pre filter Post filter DWRO membrane TURN OFF UNPLUG Close the ball valve 1 7 3 7 2 7 1 2 3 Take out the cartridge that you are replacing Insert the new cartridge and tighten to the mark position CLICK ...

Страница 26: ...lected filter element will blink 3 times and turn blue Exit mode press Clean or wait for 10 seconds TURN ON Remember to flush before consuming the water After replacing the pre or post filter open your faucet and let the water flow for 15 minutes Note that the first coming out will be black This is totally normal as some of the activated carbon is washed out After replacing the DWRO membrane the s...

Страница 27: ...o water has been consumed for more than a month You can clean your system using a moist cloth and a mild cleaning agent To protect the surfaces of the unit do not use any bleach solvent or alcohols Maintenance must be carried out by trained personnel who must handle the equipment properly as well as use original spare parts to maintain the characteristics warranty certifications and performance of...

Страница 28: ...A2O Pure UTS 800 installation manual EN Version 1 0 Revised 14 October 2022 Aquaporin A S Nymøllevej 78 2800 Kongens Lyngby Denmark VAT No DK28315694 Tel 45 82 30 30 82 sales aquaporin com aquaporin com ...

Отзывы: