AQUAPHOR RO-31 Скачать руководство пользователя страница 6

6

6. STARTING THE RO

To start the RO, it is necessary to connect the supply tubes and carry out the washing procedure of the 

cartridges 

Step 1 – Connect the delivery tubes according to fig. 2.

Blue tube – from the connection node to the inlet collector block fitting.

Blue tube – from the inlet fitting of the conditioning block to the inlet conditioning cartridge fitting 

(if necessary, shorten the tube).

Red tube – from the saddle to the drain fitting of the collector block.

White tube – from the end of the clean water tip to the outlet fitting of the conditioning cartridge.

How to connect the tubes (fig. 7a)

Remove the locking clip from the plastic sleeve. Insert 

the pre-wetted end of the tube into the nozzle sleeve until 

it stops at a depth of approximately 15 mm (0,6 inches) and 

put the locking clip back .

Check the strength of fixing the tube: with a force of 

8–10 kgf (78,4–98 N) the tube should not be pulled out.

How to disconnect the tubes (fig. 7b)

To disconnect the tubes pull the locking clip out from 

the plastic sleeve by pushing the butt of the plastic sleeve, 

then pull the tube.

Step 2 – Install the filter cartridges.

• 

Remove thermostatic tape and transporting plugs from 

the cartridges.

• 

Make sure, that the inside surfaces of the subunit flange 

cartridges are clean (no coal dust, debris, etc.). If there is 

any dust, flush it under water. 

• 

According to the (fig. 9) “the position of the cartridges In 

the  RO”,  install  the  cartridges  in  the  position  “for 

flushing”. For this insert the cartridge up to the stop to 

the  appropriate  collector  and  turn  it  in  a  clockwise 

direction until you hear a click (fig. 8а).

• 

For cartridge connection press the button and turn the cartridge counterclockwise (fig. 8b).

Step 3 – Flush the RO.

• 

Open the inlet valve;

• 

Insert the tip into the socket of the web clipper (fig. 14а), holding it above 

the sink;

• 

Holding the tip with your hand , put the web clipper in the sink, drain the 

water out from the water purifier for 10 minutes;

• 

Disconnect the tip from the web clipper by pressing the button located on 

the slam end (fig. 14b);

• 

Close the inlet tap;

• 

Place the modules in the “For operation” position (see fig. 9);

• 

Open the inlet tap;

• 

Insert the hand piece into the slot of the storage container lid;

• 

Wait for the water to enter the storage tank and drain the water;

• 

Repeat this procedure 2 times.

Figure 7a 

Figure 7b

Figure 8a 

Figure 8b

Содержание RO-31

Страница 1: ...logies Unique ion fiber Effectively and irreversibly removes heavy metals Carbon block with QUALEN completely removes chlorine organic substances and carcinogens STC Safe To Consume Materials are cert...

Страница 2: ...ers length height width Located under the sink 265 365 100 mm 10 4 14 4 39 4 inches Operational parameters of the storage tank length height width Located on the countertop 280 265 110 mm 11 0 10 4 4...

Страница 3: ...ls pesticides chloroformandheavymetals Membrane cartridge 2 Here water divides into two streams purified water ready for further treatment and drain water which includes unwanted impurities Clean wate...

Страница 4: ...pressure in the water supply Connect the connection node to the plumbing Connect the JG 1 4 tube To do this pull the locking clip off the plastic sleeve install the plastic tube previously wetted with...

Страница 5: ...e end of the threaded tail 1 to the sleeve 6 should be approx 600 mm Collector block installation Fix the block to make the distance under the water purifier with no less than 50 mm of free place It i...

Страница 6: ...hen pull the tube Step 2 Install the filter cartridges Remove thermostatic tape and transporting plugs from the cartridges Make sure that the inside surfaces of the subunit flange cartridges are clean...

Страница 7: ...y disconnected If you want to stop the filling of water into the bowl ahead of schedule just press the button located on the top of the bowl cover Return the nose into the cradle not later than 1 hour...

Страница 8: ...clicks Open the inlet tap and make sure the RO is tight Insert the assembled module into the collector block until it stops and while slightly pressing turn the module clockwise until it clicks Open...

Страница 9: ...into the sink then drain the water from the water purifier for 1 hour Disconnect the tip from the shutoff by pressing the button located on the shutoff end fig 14b Make sure the RO is sealed Condition...

Страница 10: ...nd workmanship under normal use and service Aquaphor RO 31 One Year Warranty Depending on the amount of impurities in the water the service life resource of the water treatment cartridges may vary may...

Страница 11: ...AL DAMAGES OR EXPENSES INCURRED BY THE PURCHASER OR FOR LABOR OR OTHER COSTS DUE TO INSTALLATION OR REMOVAL OR COSTS OF REPAIRS BY OTHERS OR FOR ANY OTHER EXPENSE NOT SPECIFICALLY STATED ABOVE EXCEPT...

Страница 12: ...e engineer Service engineer s signature Client s signature For installation operational and technical maintenance please contact Manufacturer EE Westaqua Invest O division of Aquaphor Corp L Tolstoi 2...

Отзывы: