Step 4. Flushing the reverse osmosis 

membrane unit

•  Remove the service plug from the slot of the 

reverse osmosis membrane unit and replace it 

with the membrane cartridge as shown in Fig. 14.

•  Turn the inlet cock of the connecting assembly 

to its open position. The cartridge life indicator 

lights blink (the light signal is followed by an 

audible signal).

•  Make sure the RO-206S connections are tight.

Attention! If leaks are found, immediately turn 

the inlet cock of the connecting assembly to its 

closed position and check the connections. Turn 

the inlet cock of the connecting assembly to its 

open position again to continue the flushing 

procedure after the leak is repaired.

•  Wait for the water to flow from the tap for treated 

water.

•  Let the water through your RO-206S for 1 hour.*

•  Close the treated water tap.

•  Fill and empty the storage tank 2 more times.

•  Press and hold the PUSH button for at least 

7 seconds. The cartridge life light indication 

changes from the flashing mode to the constant 

one, and the audio signal stops.

•  Make sure the RO-206S connections are tight.

•  Your RO-206S is ready for use once the tank 

is filled.

ATTENTION! The water is not intended for drink-

ing after flushing.

Periodically check your RO-206S for leaks during 

the first week of use. Some noise may occur 

during the first week of operation of your RO-

206S when switching the valve because of air 

released from the internal cavities of the system. 

This is not a malfunction.

7. Replacing Cartridges

Your RO-206S is equipped with a light and sound 

indication of cartridge life.
The RO-206S light and sound indication is 

configured to work with cold drinking water 

from municipal water supply systems that meet 

sanitary standards.
Each of the filtration units has an individual light 

indication (Fig. 15): indicators 1 and 4 correspond 

to cartridges K1 and K2 of the water pre-treatment 

Fig. 12

DC IN

Fig. 13

* The whole flushing procedure of the membrane cartridge takes no more than 24 hours and depends on its storage and trans-

portation conditions.

unit, indicators 2 and 3 correspond to the reverse 

osmosis membrane unit.

The flashing indicators of the filtration units

followed by a periodic sound signal, inform about the 

expired service life of the corresponding cartridge. 

In this case, the cartridge must be replaced with 

a new one.

Fig. 14

Membrane 

Membrane 

cartridge

cartridge

Содержание RO-206S

Страница 1: ...RO 206S REVERSE OSMOSIS SYSTEM Operation manual...

Страница 2: ...so the higher the water salinity the greater water supply pressure is required to keep RO 206S operating RO 206S is made of safe non toxic materials ensuring that no substances hazardous to both human...

Страница 3: ...L 1 3 m red 1 pc 3 2 1 4 JG tube d 6 35 mm L 1 2 m black 1 pc 3 3 1 4 JG tube d 6 35 mm L 1 0 m blue with an inserted metal bushing 1 pc 4 Connecting assembly 7 1 set 5 Drain clamp 8 1 set 6 Service...

Страница 4: ...uantity at any time At the front the RO 206S housing is covered with a decorative panel where an electronics unit and control elements are located 2 K1 and K2 replaceable filter cartridges are part of...

Страница 5: ...be paid to prevent the supply tubes from bending and twisting Fig 3 Your RO 206S must be installed far from or insu lated from heat sources stoves boilers hot water pipes dishwashers washing machines...

Страница 6: ...nlet cock of the connecting assembly and supply water from the cold water supply line to make sure that the connection is tight Connect the corresponding JG tube Fig 5b Fig 4 Fig 5a The inlet cock is...

Страница 7: ...The bolts should be tightened evenly so that the two parts of the clamp are parallel Put the plastic nut on the JG drain tube so that the tube extends from the other side of the nut by at least 20 mm...

Страница 8: ...ion The cartridge life indicator lights blink the light signal is followed by an audible signal On the front panel of your RO 206S Fig 13 flash the PUSH button 3 times to start the flushing mode At th...

Страница 9: ...206S is ready for use once the tank is filled ATTENTION The water is not intended for drink ing after flushing Periodically check your RO 206S for leaks during the first week of use Some noise may occ...

Страница 10: ...rtridge into the corresponding collector until it stops and turn clockwise as shown in Fig 10a until a click Replacement of K1 K2 filter cartridges and the membranes cartridges Modes Sound alarm LED o...

Страница 11: ...f the connecting assembly The cartridge life light indicators turn on the flashing light indicator of the reverse osmosis membrane unit is followed by a sound signal Make sure the RO 206S connections...

Страница 12: ...tems that meet sanitary standards It is recommended to analyse the water source for compliance with national standards for drinking water when installing RO 202S outside municipal water supply systems...

Страница 13: ...prehensive warranties in the industry Aquaphor warrants that the Aquaphor water filtration system shall be free from defects in material and workman ship under normal use and service Aquaphor Reverse...

Страница 14: ...EXCLUSION MAY NOT APPLY TO YOU If you have any issue with the operation of your RO 206S please contact the seller or the manufacturer Service life operating time of replaceable filtering cartridges N...

Страница 15: ...er supply plug is not plugged into the outlet Insert the plug of the power supply into a power outlet The power supply plug is not plugged into the coaxial connector of the RO 206S Insert the power su...

Страница 16: ...r Corp L Tolstoi 2A Sillam e Estonia 40231 www aquaphor com The manufacturer reserves the right to make improvements to the design of the RO 206S without being mentioned in this Manual The date of man...

Отзывы: