AQUAPHOR RO-206S Скачать руководство пользователя страница 7

7

Installation of the drain clamp* (Fig. 7)

* The manufacturer reserves the right to use connecting assemblies and taps of a similar design. If you have any questions, 

please, contact the service department.

Fig. 7a

Installation of the treated water tap (Fig. 6)

Fig. 7b

Fig. 6

3

2

1

•  It is recommended to install the clamp on the 

sink drain upstream of the S-trap (the drain 

clamp fits most drain pipes which are about 

40 mm in diameter).

•  Attach the part of the clamp with the fitting to 

the pipe and find the optimal position of the 

clamp and a hole for the tube.

•  Drill a 7 mm hole in the pipe wall in the intended 

place.

•  Remove the cut round part from the gasket (1).

•  Remove the protective film (2) from the gasket 

(1). Attach the gasket (1) on the inside of the 

clamp so that the hole in the gasket aligns with 

the hole in the clamp fitting.

•  Install the clamp on the pipe, aligning the hole 

in the fitting with the drilled hole in the pipe, 

and then tighten the bolts (3). The bolts should 

be tightened evenly so that the two parts of 

the clamp are parallel.

•  Put the plastic nut on the JG drain tube so that 

the tube extends from the other side of the nut 

by at least 20 mm (Fig. 7b).

•  Insert the tube into the drain clamp and screw 

the nut onto the fitting.

Note. Push the JG tube deeper into the pipe if 
you are disturbed by the sound of water coming 
from the drain clamp.

•  Drill a 12 mm hole in the sink (benchtop).

•  Place the rubber gasket (2), the decorative plate 

(3), the rubber gasket (4) on the threaded shank 

of the tap (1) and insert the tap into the sink hole.

•  Put the plastic (5) and the metal (6) lock washers 

on the threaded shank from the bottom of the 

benchtop and screw the fixing nut (7) until tight 

(you can use a 14 mm pipe wrench).

•  Insert the metal sleeve (8) into the blue tube (10), 

and the tube into the threaded shank of the tap 

(1) and tighten the clamping nut (9) until tight.

•  Check that the tube (10) is tight. The tube should 

not be pulled out using a force of 80-100 N.

ATTENTION! It is recommended to use the stand-
ard RO-206S tap for treated water. Using other 
taps may result in humming and other unusual 
sounds.

2

1

3

8

9

10

7

5
6

4

Содержание RO-206S

Страница 1: ...RO 206S REVERSE OSMOSIS SYSTEM Operation manual...

Страница 2: ...so the higher the water salinity the greater water supply pressure is required to keep RO 206S operating RO 206S is made of safe non toxic materials ensuring that no substances hazardous to both human...

Страница 3: ...L 1 3 m red 1 pc 3 2 1 4 JG tube d 6 35 mm L 1 2 m black 1 pc 3 3 1 4 JG tube d 6 35 mm L 1 0 m blue with an inserted metal bushing 1 pc 4 Connecting assembly 7 1 set 5 Drain clamp 8 1 set 6 Service...

Страница 4: ...uantity at any time At the front the RO 206S housing is covered with a decorative panel where an electronics unit and control elements are located 2 K1 and K2 replaceable filter cartridges are part of...

Страница 5: ...be paid to prevent the supply tubes from bending and twisting Fig 3 Your RO 206S must be installed far from or insu lated from heat sources stoves boilers hot water pipes dishwashers washing machines...

Страница 6: ...nlet cock of the connecting assembly and supply water from the cold water supply line to make sure that the connection is tight Connect the corresponding JG tube Fig 5b Fig 4 Fig 5a The inlet cock is...

Страница 7: ...The bolts should be tightened evenly so that the two parts of the clamp are parallel Put the plastic nut on the JG drain tube so that the tube extends from the other side of the nut by at least 20 mm...

Страница 8: ...ion The cartridge life indicator lights blink the light signal is followed by an audible signal On the front panel of your RO 206S Fig 13 flash the PUSH button 3 times to start the flushing mode At th...

Страница 9: ...206S is ready for use once the tank is filled ATTENTION The water is not intended for drink ing after flushing Periodically check your RO 206S for leaks during the first week of use Some noise may occ...

Страница 10: ...rtridge into the corresponding collector until it stops and turn clockwise as shown in Fig 10a until a click Replacement of K1 K2 filter cartridges and the membranes cartridges Modes Sound alarm LED o...

Страница 11: ...f the connecting assembly The cartridge life light indicators turn on the flashing light indicator of the reverse osmosis membrane unit is followed by a sound signal Make sure the RO 206S connections...

Страница 12: ...tems that meet sanitary standards It is recommended to analyse the water source for compliance with national standards for drinking water when installing RO 202S outside municipal water supply systems...

Страница 13: ...prehensive warranties in the industry Aquaphor warrants that the Aquaphor water filtration system shall be free from defects in material and workman ship under normal use and service Aquaphor Reverse...

Страница 14: ...EXCLUSION MAY NOT APPLY TO YOU If you have any issue with the operation of your RO 206S please contact the seller or the manufacturer Service life operating time of replaceable filtering cartridges N...

Страница 15: ...er supply plug is not plugged into the outlet Insert the plug of the power supply into a power outlet The power supply plug is not plugged into the coaxial connector of the RO 206S Insert the power su...

Страница 16: ...r Corp L Tolstoi 2A Sillam e Estonia 40231 www aquaphor com The manufacturer reserves the right to make improvements to the design of the RO 206S without being mentioned in this Manual The date of man...

Отзывы: