Power Use Advice: The main Power Supply Switch(With the Creepage Protection Switch )
should be mounted about 1000 mm away from the steam room during installation in the site
so that the power can be cut off after each use to ensure safety and the service life of computer
control system of the product.
Plumbing
&
Electrical
Pla ne Dimension Draw ing
Three-dimensional Installation Dimension Drawing
3
0
0
400
400
1000
1500
800
200
1100
200
Ground wire
connector
Drainage Hole
Hot water
Cold water
Ground wire
connector
25A Waterproof
Creepage protection
Switch
20A
waterproof
socket
1.Water Supply: One Cold and one Hot pipe. Shut-off Valve with outside Yoke (DN15(G1/2))shall be
mounted on the wall which should be 1000mm above from the ground. 0.15mPa=Pressure=0.4mPa.
2.The steamer power: 4500W. Power supply voltage:AC220V
±
10%. Frequency:50Hz. Single Phase and
Three Wire System with 3X4mm2 rubber-insulated copper wire which is independent loop. The steamer is
mounted with the Creepage Overload Protection device and must have the reliable ground wire. Bathtub
body: 7500W/AC220V/50Hz. Single Phase and Three Wire System. BV=3x2.5mm2. With one 10A Water
Proof Socket. This product must be powered through Electric Creepage protection plug and Overload
Protection Device with less than 30mA electric current. The ground wire of appliance must be permanently
connected to valid and reliable ground wire of Power Supply.
3.Water Drainage: The floor drainage hole should be the same or bigger than DN50, and should be on a
line with the ground.
2
2
1
0
m
m
1620 mm
1620 mm
1620 mm
1620 mm
1
6
2
0 m
m
3
Содержание WG-U6811
Страница 8: ...Installation Steps M6 25Screw 4 M6 25Screw 4 7 ...
Страница 23: ...Aquapeutics Aquapeutics ...