Water supply: 

Hot and cold water supply lines are half inch NPT pipe thread 

 

Power supply

A 220Volt

13 amp service with GFI is necessary to energize the steam room-spa and a 

110 volt 11.8 amp circuit with GFI is needed for the whirlpool bath. Please note: If you have purchased a 
Tub with the additional heater option it is very important to understand that the electrical requirements 
for your unit have changed. The heater requires a second separate electrical circuit that can supply 13 
amps at 110 volts with GFI in addition to what your tub had originally needed.   

B

The  size  of  breakers  and  wire  gages  needed  is  determined  by  local,  state  and  national  codes  as 

interpreted  by  the  installing  electrician.  The  length  of  the  wire  going  to  the  steam  generator  from  the 

wall should be 5 feet, while the length of the telephone line needed is 7 feet. This allows the unit to be 

pulled out from the side walls if maintenance is ever needed.   

C

Drainage: The diameter of the drain pipe needs to be at least 2 inches. The position of the drain hole 

can  be  within  6  inches  from  the  hole  shown  in  the  drawing  on  the  previous  page. 

It  is  also  very 

important that the drain line not have a trap.

 It must be a straight drain line, as the shower-spa has its 

own built in trap for your convenience.

 

 

Notes:   

(1) The distance from the top of the steam room to the ceiling of the area where it is installed should be 

4 inches or greater. (The room should be at least 4 inches taller than the spa.) 

(2) It is recommended that the water pressure be at least 43 PSI and both the cold and hot water pressure 

should be as equal as possible. If the pressure is lower than required,  have your plumber install the 

necessary equipment to increase the water supply pressure. 

(3) Please have ground fault interrupter (GFI) protection on all power supply lines to the spa.   

(4)    It  is easier to line up all panels with the hardware loose. During  initial assembly please attach all 

fasteners loosely, then when the unit is completely erected, snug up all bolts and screws.   

Содержание Caribbean

Страница 1: ...0 CARIBBEAN INSTALLATION MANUAL ...

Страница 2: ...se keep in mind that like most shiny bathroom surfaces when they get wet they may become slippery Take care not to slip or fall 2 Children should only use this product under adult supervision 3 Users who suffer from heart disease or have high blood presser should exercise greater care when using this product 4 Senior citizens pregnant women and those who are of ill health are advised to get a doct...

Страница 3: ...o position during installation 4 Tools Wooden mallet open end wrench level Tape measure Screwdriver Pencil 4mm Hex wrench Electrical data Dimensions inches N W capacity Circuits Power frequency Length Width Height 1 110V 11 8 amps 1 220V 13 6 amps 1300W and 3000W 50 60Hz 63 8 63 8 87 390 lbs 40 Gal Please note If you have purchased a Tub with the additional heater option it is very important to un...

Страница 4: ...3 Drain pipe can be offset as much as 6 inches from tub drain 2 2 Installation drawing for waste plug Installation instructions Rough Plumbing Electrical ...

Страница 5: ... from the side walls if maintenance is ever needed C Drainage The diameter of the drain pipe needs to be at least 2 inches The position of the drain hole can be within 6 inches from the hole shown in the drawing on the previous page It is also very important that the drain line not have a trap It must be a straight drain line as the shower spa has its own built in trap for your convenience Notes 1...

Страница 6: ...gram Figure 2 is below Please insert the rubber gaskets between the glass and aluminum channels where indicated The glass walls are framed by the curved rails on the top and bottom and with the aluminum extrusions to the left and right Connect the left and right fixed glass walls 2c to the upper and lower aluminum curved rails 2d by using 8 pieces 3 16 x 1 inch 2a screws with the plastic chrome sp...

Страница 7: ...tion diagram as follows Figure 4 Using x 1 inch bolts 3a connect the left and right small panels 3b 3c to the middle panel 3d respectively to complete the whole back panel of your steam shower 3e Figure 4 1 Figure 4 1 Figure 4 ...

Страница 8: ...d the Glass wall and door assembly 3g onto the bathtub attach the glass door to the back board by using3 16x 3 4 inch bolts Figure 4 3 4 Final installation steps Figure4 2 Figure 4 3 Figure 5 Place the ceiling roof of the spa 3i onto the unit then using 1 4x 1 inch bolts bolt it to the back panel and use 3 16x 3 4 inch screws to fasten the roof to the glass wall door Figure 5 ...

Страница 9: ...ass door You want the door to be as plumb as possible After the correct positions for the top eccentrics have been determined then you can tighten them as needed Now the bottom eccentrics may be installed using a similar method only no fine tuning is necessary The bottom ones are simply inserted first their lowest position and then twisted 180 degrees to their highest position to lock them into th...

Страница 10: ...te outlets inlets are labeled in the above diagram and are visible in the photo below The Steam generator drain hose is pushed onto the fitting straight or elbow connected to the Steam Generator It is secured to this fitting by a clamp and a 3 16 X 5 8 inch round head fastener as is shown in the above figure It is also shown assembled in the photo below Outside of spa Figure 7 4c Figure 8 Steam ou...

Страница 11: ...Black insulated high temperature steam pipe Front and side view of Steam outlet Figure 10 Figure 11 Rainfall shower hose When bending the insulated steam hose please Use Extreme Care not to crimp the hose as you feed it through the appropriate hole in the tub section The rubber washer gasket that is secured by a wire tie is inserted into the end of Steam hose The all silver hose is the water suppl...

Страница 12: ...e ozonizer O3 shower self cleaner Connect the wires sharing the same labels and or properly mated connector pairs The radio antenna will need to be unrolled and placed for best reception See figure 12 16 Connect the hot and cold water hoses the red one is for hot water while the blue one is for cold Both the hot and cold water supply lines are half inch NPT pipe thread Figure 12 ...

Страница 13: ...on the next page Pick a side wall water jet pipe that is convenient to work on Measure the distance taken up by the water heater Approximately 7 and 5 8 inches Cut this part out Glue the ends of the water heater and wait until the glue sets as per the manufactures instructions Plug the heater in It has its own thermostatically controlled on off and temperature controls It will turn on when there i...

Страница 14: ... with a high grade silicone sealant Then fully test the unit Then slide it into its final installed position 4 Spray and foot massage installation 4 1 Connect the hose of the hand held shower head B by screwing it into nozzle A as depicted below and then put the hand held shower head into its cradle C Figure 14 Figure13 Figure 14 ...

Страница 15: ... massage position water comes out of the left body massage jets When control knob 5c is opened then both sets of body massage jets will work Knob 5a3 adjusts the temperature of the water and knob 5a2 is used to adjust the amount or rate of the water entering the spa The five way selector 5a1 may be set to and from any position even with the water running 4 2 Use the same technique to install the f...

Страница 16: ...6 Water route connecting diagram Body ...

Страница 17: ...l box or the steam generator Doing so will void your warrantee There are no user serviceable parts inside DO NOT repair or replace these units on your own If you do experience any problems please contact Aquapeutics Toll Free Customer Service line 1 800 290 6812 for after sale service ...

Отзывы:

Похожие инструкции для Caribbean