14
VCS - Viscomaster™
Procedure
3.2.2.2
Mount with an inline viscosity retrofit kit
The inline viscosity retrofit kit provides a simple, direct replacement for existing meters.
Typically, the flange-to-flange distance is 150 mm (5.9 in), although Aquametro Oil & Marine can accommodate
larger versions. Usually, no pipework changes are necessary.
CAUTION!
Observe all corporate and government safety regulations. Wear protective clothing,
safety glasses, and gloves to prevent burns and the absorption of hot oil.
Prerequisites
Verify the following conditions:
Temperature
–50 °C to 200 °C (–58 °F to 392 °F)
Flow
40 to 330 l/min
2.5 to 20 m
3
/hr
11 to 87 US gal/min
Viscosity
Up to 100 cSt
Pressure
As defined by process flanges
Calibration
boundary
2.5 in Schedule 40
Содержание Viscomaster