Page 6

 

Other Maintenance:

 

 

Replace the ballast 

(all models):

 

 

Turn off or unplug pump.

 

 

Unplug UV ballast.

 

 

Remove both rubber end plugs from UV sterilizer by light pulling on the ballast cord.

 

 

Disconnect ballast and lamp socket from UV lamp.

 

 

Install new ballast with rubber end plugs and lamp sockets.

 

 

Turn on or plug in pump.

 

 

Plug UV ballast into its outlet.

 

 

After a few seconds, the view port should glow with a blue color. 

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Parts Listing: 

All replacement parts are available directly from Aqua Logic, Inc. 

 

Catalog number 

Bulbs: 

UV-BULB-095W-1 

ALA-95ST Watt Bulb 

 

Ballast:

 

UV-BAL-95W-1 

ALSLTB-2 Potted ballast  

 

Quartz Sleeve:

 

UV-QTZ-40X43 

MUV-Q - Compact UV 48 in Quartz Sleeve (

Two lamps

UV-QTZ-Q95T 

ALSV-Q24T Test tube quartz sleeve (Single Lamp) 

 

Miscellaneous:

 

UV-SOC-95STEP 

ALA-95S, Step pin socket 

UV-OR-SIL-RED 

8820-200-326 Quartz red O ring 

UV-OR-SPLIT 

MIC001PGRR001 Spilt PTFE “O” Ring 

MUV-CAP 

1-1/4” Compression Nut 

FT-R-PLUG-000-1 

Plug, tapered rubber grommet  

 

 

Содержание ALSLT Series

Страница 1: ...CA 92126 Effective 02 09 16 Ph 858 292 4773 FAX 858 279 0537 email info aqualogicinc com website www aqualogicinc com Page 1 ALSLT SERIES UV STERILIZER INSTRUCTIONS Effective 2 9 16 Please read all in...

Страница 2: ...se the equipment if it has been dropped into water Do not operate this unit if it has a damaged cord or plug if it is malfunctioning or if it has been dropped or been damaged in any manner Never yank...

Страница 3: ...kill fungi and protozoa parasites UV sterilizers do NOT affect water chemistry lower the livestock s immune systems nor affect established biological filtration systems How do I know which size UV I...

Страница 4: ...organics within the UV sterilizer You may use either flexible tubing or rigid pipe Do not exceed the maximum flow rate for your unit as shown on the specification sheet Connect the output from the UV...

Страница 5: ...gs and or quartz sleeve See Drawing WARNING Be sure to wear protective gear for your hands and eyes Turn off or unplug the pump Unplug the UV ballast Isolate or remove UV from system Drain the water f...

Страница 6: ...kets Turn on or plug in pump Plug UV ballast into its outlet After a few seconds the view port should glow with a blue color Parts Listing All replacement parts are available directly from Aqua Logic...

Страница 7: ...solution from the UV sterilizer Rinse or flush the unit thoroughly to remove all chlorine Continue to flush until you can no longer smell chlorine You may wish to add a few drops of a de chlorinator...

Страница 8: ...warranty may not be modified by verbal statements by the manufacturer distributors retailers their agents nor any other party The warranty covers only the repair or replacement of the AQUA LOGIC prod...

Отзывы: