Replace Lamp in all Models
WARNING: Be sure to wear protective gear for your hands and eyes!!
•
Turn off or unplug pump.
•
Unplug UV ballast from outlet.
•
Remove both rubber end plugs from UV sterilizer
by carefully pulling on ballast wire.
•
Carefully slide UV lamp from quartz sleeve just
enough to expose the white lamp socket.
•
Hold the lamp socket with one hand and with the
other hand hold the lamp. Carefully pull apart the
connector from the lamp.
•
Remove lamp by sliding it out of the unit.
•
Slide replacement lamp into the quartz sleeve.
[DO NOT force the lamp into the sleeve or you
may break the quartz sleeve! We recommend
using Aqua Logic certified lamps for a perfect fit.]
•
Attach lamp socket to the new lamp and carefully
slide the lamp in to position where the rubber
cover plugs seat correctly.
•
Turn on or plug in pump.
•
Carefully inspect for leaks.
•
Plug UV sterilizer ballast into outlet.
•
The view port should show a blue light after a few seconds.
Replacing the quartz O-rings and/or quartz sleeve
[See Drawing]
WARNING: Be sure to wear protective gear for your hands and eyes!!
•
Turn off or unplug the pump.
•
Unplug the UV ballast.
•
Isolate or remove UV from system.
•
Drain the water from the unit.
•
Disconnect and remove UV lamp from quartz sleeve.(use instructions from above)
•
Remove the compression nuts on each end of the UV. [NOTE: Some water may leak out during
this procedure.] If you cannot loosen them by hand, you may obtain a UV lamp removal wrench
from your distributor or from Aqua Logic Systems or use a pair of adjustable spanner pliers.
•
Remove both red O-rings and Teflon rings.
•
Carefully slide the quartz sleeve from the chamber in the same manner as removing the lamp.
•
If you are not replacing the O-rings them, inspect them carefully for damage or cracks.
•
Carefully slide the new or cleaned sleeve back into the chamber until it is approximately centered
in the sterilizer.
•
Slide the red O-rings and Teflon rings onto the sleeve and snug them evenly against their seats.
•
Screw the compression nuts back on. Hand tighten only. Do
NOT
over tighten.
•
Reinstall the UV lamp and reconnect the lamp sockets with the rubber end plug snuggly in place.
•
Reconnect the UV to the plumbing.
•
Turn on or plug in pump.
•
Inspect carefully for leaks.
•
Plug UV ballast into its outlet.
•
After a few seconds, the view port should glow with a blue color.